A Study to Evaluate a New Jaundice Stick Test

Field Evaluation of a Point-Of-Care Test for Serum Bilirubin Levels in Infants Born in a Tropical Limited-resource Setting.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02926131
Acronym
Bilistick
Enrollment
180
Registered
2016-10-06
Start date
2017-01-25
Completion date
2017-12-11
Last updated
2018-10-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Jaundice, Serum Bilirubin

Keywords

stick test

Brief summary

This is an observational prospective study. The main purpose is to evaluate the stability of the Bilistick system in a humid and hot climate compared to the quantitative test for serum bilirubin (SBR) measurement currently used, the BR-501 total bilirubin meter, kept in a controlled environment. The secondary aim is to assess the operational feasibility of the Bilistick system in a tropical limited-resource setting, when used by locally trained nurses.

Detailed description

Study procedure: 1. SBR will be measured in parallel with two tests during three distinct seasons. (Cold, hot, rainy). The Blood is from an extra capillary sample taken from a single heel prick done for routine SBR) BR-501 total bilirubin meter, the quantitative test for SBR currently used, will be kept in a controlled environment while the new bilirubin test (Bilistick system) will be exposed to tropical conditions. 2. Trained nurses will use the Bilistick system observed by a qualified laboratory technician; Usability of the Bilistick system by the trained nurses will be evaluated via a 5-point Likert scale questionnaire and focus groups discussions.

Interventions

OTHERBlood sampling

* One full capillary tube (50µl blood) will be used to measure the Hct level and the routine SBR using the BR-501 bilirubin meter machine (non-study procedure). * An additional half- filled capillary tube (25µl blood) will be used for the SBR measurement with the Bilistick system

Sponsors

Shoklo Malaria Research Unit
CollaboratorOTHER
University of Oxford
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Days to 28 Days
Healthy volunteers
Yes

Inclusion criteria

* Written or thumb print for informed consent from the parent * Infant born ≥ 35 weeks of gestational age * Infant who needs a routine SBR measurement * Infant in stable clinical condition prior to SBR measurement confirmed by the trained nurses

Exclusion criteria

The participant will not be enrolled in the study if ANY of the following applies: * Infant who already had 1 SBR measurement done with the Bilistick system * Last haematocrit measurement \> 65% or no previous haematocrit measurement

Design outcomes

Primary

MeasureTime frameDescription
Comparison of the agreement of serum bilirubin measurement between the two tests in three different seasons18 monthsThe main outcome of interest is the potential effect of environmental conditions on the quantitative outcome of the Bilistick System, using BR-501 bilirubin meter machine as a reference. The Bland-Altman analysis will be used to compare the two tests.
Within each season, evaluation of the impact of temporal variation on the agreement of serum bilirubin measurement between the two tests.18 monthsA linear regression analysis will be done to look for statistically significant effect of exposure time on the difference between the average total bilirubin serum levels of the two tests.

Secondary

MeasureTime frameDescription
Evaluation of the usability of the Bilistick system using a 5-point likert scale questionnaire and a focus group discussions18 months5-point likert scale questionnaire will be filled individually by the trained nurses at the end of each defined season. Quantitative variables related to the secondary outcomes will be measured with the mean, median and ratio according to the distribution of the variable and compared with appropriated statistical test.
Perception by the trained nurses of the Bilistick system usability with a focus group discussion (FGD).18 monthsThe FGD will be centered around the answers obtained from the questionnaires and the concerns raised by the trained nurses and laboratory technicians during each recruitment period. Qualitative variable from the focus group will be analysed with Nvivo.

Countries

Thailand

Outcome results

None listed