Comparison of Electronic Calipers to Conventional Calipers and X-ray Measurement of Spinal Tilt

Comparison of Electronic Caliper Measurements of Spinal Tilt to Conventional Caliper and X-ray Measurements of Spinal Tilt

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02920255
Enrollment
100
Registered
2016-09-30
Start date
2016-10-31
Completion date
2017-11-30
Last updated
2016-10-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lower Back Pain

Brief summary

The objective is to compare the accuracy and reproducibility of measurements taken with electronic calipers and conventional calipers. Using both calipers, reproducibility will be determined by comparing results from a number of practitioners and accuracy will be determined by comparing results with those obtained from X-rays.

Detailed description

Participants will have 2 spinal measurements, one at the shoulder and one at the hip, taken by electronic calipers and conventional calipers with different individual research staff. Up to 5 individual research staff will take the 2 spinal measurements on each participant. This will be done to compare variation of measurements between individual operators. The accuracy of the spinal measurements, obtained with electronic and conventional calipers will be compared to the results obtained from x-rays taken of shoulder and hip areas. Only one x-ray of the shoulder and one x-ray of the hip will be taken of each participant. X-rays represent the clinically accepted standard of obtaining spinal measurements. The data will analyzed statistically to determine sources of variation among the methods of spinal measurement described above.

Interventions

OTHERDiagnostic

Measurement of spinal tilt

Sponsors

KKT Orthopedic Spine Center
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
Yes

Inclusion criteria

Must be able to have shoulder and hip measurements for spinal tilt

Exclusion criteria

Not able to have shoulder and and hip measurements for spinal tilt.

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of Electronic Caliper Spinal MeasurementsThrough study completion, an average of 13 monthsAll measurements will recorded in degrees of spinal tilt.

Secondary

MeasureTime frameDescription
Accuracy of Conventional Caliper Spinal MeasurementsThrough study completion, an average of 13 monthsAll measurements will recorded in degrees of spinal tilt.
Accuracy of X-ray Spinal MeasurementsThrough study completion, an average of 13 monthsAll measurements will recorded in degrees of spinal tilt.
Reproducibility of Electronic Caliper MeasurementsThrough study completion, an average of 13 monthsAll measurements will recorded in degrees of spinal tilt.
Reproducibility of Conventional Caliper MeasurementsThrough study completion, an average of 13 monthsAll measurements will recorded in degrees of spinal tilt.
Reproducibility of X-ray MeasurementsThrough study completion, an average of 13 monthsAll measurements will recorded in degrees of spinal tilt.