Skip to content

Angel® Catheter Post Market Registry

European Angel® Catheter Post Market Registry

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02917135
Enrollment
2000
Registered
2016-09-28
Start date
2016-07-31
Completion date
2018-07-31
Last updated
2016-12-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Catheter-related Bloodstream Infection (CRBSI) Nos, Catheter Thrombosis, Deep Vein Thrombosis, Medical Device Complication, Pulmonary Embolism

Brief summary

This is a post-market, observational, retrospective multi-center Registry designed to gather information on the performance of the Angel® Catheter in general clinical practice.

Detailed description

The Registry population will include all consecutive patients in whom the Angel® Catheter is placed at participating sites. Information about the use of the catheter will be collected from placement through three days after device removal, or through death or discharge, whichever occurs first. Date of discharge/transfer from the Critical Care Unit will also be collected, completing the defined registry observation. Information on up to 2,000 patients will be abstracted from a patient chart review. Sites will be asked to record data on all Angel® Catheter placements in their institution starting with their first Angel® Catheter placement after training by BiO2 Medical, Inc. personnel once all necessary institutional approvals are obtained confirming that Informed Consent is not required from the patient or LAR to collect, use, or publish patient data from this registry. The registry population will include all consecutive patients in whom the Angel® Catheter is placed, or there has been an attempt to place, at selected Registry sites. The Instructions for Use (IFU) for the Angel® Catheter include the following indications: * Pulmonary thromboembolism when anticoagulants are contraindicated; or * Failure of anticoagulant therapy in thromboembolic diseases; or * Emergency treatment following massive pulmonary embolism where anticipated benefits of conventional therapy are reduced; and or * Critically ill patients at high risk of pulmonary embolism, not receiving medical thromboprophylaxis due to either increased risk of bleeding, active bleeding or heparin induced thrombocytopenia. Since the Angel® Catheter is indicated for use in pregnant patients, patients who are pregnant may be included in this Registry after the proper risks and benefits have been assessed by the physician. In summary, the Registry Event Schedule and data collection includes the following: * Demographics and Current Medical Condition: Information collected to include demographics, medical condition and indication/s for use of the Angel® Catheter as recorded in the patient chart. * Device Placement: Placement procedure data will be collected. If the catheter cannot be placed for some reason, no further follow up information will be collected on these patients. * Angel® Catheter Indwelling experience: While the Angel® Catheter is in place during the patient's hospital stay, information regarding anticoagulation use (eCRF form #9), any complications, clinically significant PE, lower extremity DVT will be collected through three days after device retrieval, discharge from the hospital, or death, whichever occurs first. * Device Retrieval: Information on ease of catheter retrieval and other key aspects will be collected. * Registry Exit: Information about the patient's status at three days post device removal, death, or discharge from the hospital, whichever occurs first will be collected. The patient's date of discharge/transfer from the Critical Care Unit will also be collected. * Anticoagulation Therapy: Information about the use of anticoagulation throughout the patient's observation period will be collected.

Interventions

The Angel® Catheter is a retrievable inferior vena cava (IVC) filter attached to a multi-lumen central venous access (CVC) catheter. The device is designed to be placed at the bedside in the inferior vena cava, via the femoral vein, for the prevention of pulmonary embolism (PE) and for access to the central venous system. The Angel® Catheter is intended for short-term (less than 30 days) vascular access via the femoral vein.

Sponsors

BiO2 Medical
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* All consecutive patients in whom the Angel® Catheter is placed, or there has been an attempt to place.

Exclusion criteria

* N/A

Design outcomes

Primary

MeasureTime frame
Rate of averted PEAt the time of the pre-removal cavogram

Secondary

MeasureTime frame
Incidence and seriousness of all device-related adverse eventsWhile the Angel Catheter is in place, including the insertion and removal procedures (Up to 30 days)
Incidence and seriousness of deep vein thrombosisFrom device placement through hospital discharge, death, or 3 days post-removal, whichever occurs first (Up to 33 days)
Incidence and seriousness of catheter-related thrombosisFrom device placement through removal (Up to 30 days)
Incidence and seriousness of clinically significant PEFrom device placement through hospital discharge, death, or 3 days post-removal, whichever occurs first (Up to 33 days)

Countries

Germany, Italy, United Kingdom

Contacts

Primary ContactVickie Arford, RN
varford@bio2medical.com720-833-5695
Backup ContactLuis Angel, MD
langel@bio2medical.com

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026