Skip to content

ACURATE Neo™ AS Aortic Bioprosthesis for Implantation Using the ACURATE neoTM AS TF Transfemoral Delivery System in Patients With Severe Aortic Stenosis

ACURATE Neo™ AS Aortic Bioprosthesis for Implantation Using the ACURATE neoTM AS TF Transfemoral Delivery System in Patients With Severe Aortic Stenosis

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02909556
Enrollment
120
Registered
2016-09-21
Start date
2016-12-16
Completion date
2023-01-13
Last updated
2023-02-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Stenosis

Keywords

Transcatheter Aortic Valve Replacement, TAVI, Transcatheter Aortic Valve Implant, Transfemoral access

Brief summary

Clinical trial aimed at evaluating the safety and performance of the ACURATE neo™ AS Aortic Bioprosthesis and ACURATE neo™ AS TF Transfemoral Delivery System for CE mark approval purposes.

Detailed description

Single arm, prospecitve, multicenter, non-randomized and open trial. The purpose of this trial is to collect and safety and performance data concerning the ACURATE neo™ AS Aortic Bioprosthesis and ACURATE neo™ AS TF Transfemoral Delivery System The ACURATE neo™ AS Aortic Bioprosthesis and ACURATE neo™ AS TF Transfemoral Delivery System are intended for use in minimally invasive, transcatheter aortic valve replacement (TAVR) using transfemoral access in patients presenting with severe aortic valve stenosis. The primary objective is to evaluate the safety and performance of the study device in patients presenting with severe aortic stenosis (AS) considered to be high risk for surgery. The secondary objective is to evaluate adverse events and study device performance.

Interventions

DEVICETranscatheter aortic valve replacement

Transcatheter aortic valve replacement via transfemoral access

Sponsors

Symetis SA
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
75 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patient 75 years of age and older 2. Severe aortic stenosis defined as: * Mean aortic gradient \> 40 mmHg or * Peak jet velocity \> 4.0 m/s or * Aortic valve area of \< 1.0 cm2 3. High risk candidate for conventional AVR defined as: * Logistic EuroSCORE 1 ≥ 20% or * STS Score ≥ 8% or * Heart team (cardiologist and cardiac surgeon) consensus that patient is not a surgical candidate for conventional AVR due to significant co-morbid conditions unrelated to aortic stenosis 4. NYHA Functional Class \> II 5. Aortic annulus diameter from ≥ 21mm up to ≤ 27mm by CT 6. Patient willing to participate in the study and provides signed informed consent

Exclusion criteria

1. Congenital aortic stenosis or unicuspid or bicuspid aortic valve 2. Non-stenotic Aortic Insufficiency 3. Severe eccentricity of calcification 4. Severe mitral regurgitation (\>2+) 5. Presence of mitral bioprosthesis 6. Presence of previously implanted aortic bioprosthesis 7. Presence of prosthetic ring 8. Anatomy NOT appropriate for transfemoral implant due to the size, disease and degree of calcification or tortuosity of the aorta or ilio-femoral arteries 9. Thoracic (TAA) or abdominal (AAA) aortic aneurysm 10. Presence of endovascular stent graft for treatment of TAA or AAA 11. Trans-oesophageal echocardiogram (TEE) is contraindicated 12. Evidence of intra-cardiac mass, thrombus or vegetation 13. Severe ventricular dysfunction with ejection fraction \< 20% 14. Any percutaneous intervention, except for balloon valvuloplasty (BAV) within 1 month prior to implant procedure 15. Acute Myocardial Infarction within 1 month prior to implant procedure 16. Previous TIA or stroke within 3 months prior to implant procedure 17. Active ulcer or gastrointestinal (GI) bleeding within 3 months prior to implant procedure 18. Any scheduled surgical or percutaneous procedure to be performed prior to 30 day visit 19. Severe coagulation conditions 20. Refusal of blood transfusions 21. Systolic pressure \<80mmHg, cardiogenic shock, need for inotropic support or IABP 22. Hypertrophic cardiomyopathy with or without obstruction 23. Active bacterial endocarditis or other active infections 24. Hepatic failure (\> Child B) 25. Chronic renal dysfunction with serum creatinine \> 2.5 mg/dL or renal dialysis 26. Refusal of surgery 27. Severe COPD requiring home oxygen 28. Neurological disease severely affecting ambulation or daily functioning, or dementia 29. Life expectancy \< 12 months due to non-cardiac co-morbid conditions 30. Inability to tolerate anticoagulation therapy 31. Contraindication to contrast media or allergy to nickel 32. Currently participating in an investigational drug or another device study 33. Non-valvular aortic stenosis 34. Non-calcific acquired aortic stenosis

Design outcomes

Primary

MeasureTime frame
Rate of all-cause mortality at 30 days follow-up30 days post-implant

Secondary

MeasureTime frameDescription
Procedural successDay of implant2\. Procedural success defined as absence of complications arising during implantation of the prosthetic valve such as: inability to properly seat the valve in the annulus; need for more than one aortic bioprosthesis (valve in valve); or if a surgical aortic valve replacement is required to correct a severe aortic regurgitation or procedure complication
Device successDay of implant3\. Device success defined as: * Absence of intra-procedure mortality AND, * Correct positioning of a single prosthetic heart valve into the proper anatomical location AND, * Intended performance of the prosthetic heart valve (EOAi \>0.85 cm2/m2 and mean aortic valve gradient \<20mmHg without moderate or severe AR)
VARC Composite Safety at 30 days30 days
Rate of clinical events as defined per VARC guidelines7 days, 30 days, 12 months post-implantClinical events: * Mortality * Stroke * Myocardial infarction * Bleeding complication * Acute kidney injury * Vascular complication * Conduction disturbances and arrhythmia * Other TAVI-related complications
Improvement from baseline in hemodynamic function: effective orifice area, mean transprosthetic gradient7 days, 30 days, 12 months
Total aortic regurgitation7 days, 30 days, 12 months
Clinical improvement from baseline as per NYHA Functional Classification7 days, 30 days, 12 months post-implant

Countries

Denmark, Germany, Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026