Skip to content

Comparative Effectiveness of an Activity-specific Monitoring Device- StepRite

Comparative Effectiveness of an Activity-specific Monitoring Device- StepRite - on Short Term Outcomes in Adults After Partial or Total Knee Arthroplasty

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02900781
Enrollment
9
Registered
2016-09-14
Start date
2016-10-21
Completion date
2017-11-30
Last updated
2019-08-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Degenerative Joint Disease, Osteoarthritis

Keywords

Arthroplasty, Physical Therapy

Brief summary

Partial or Total Knee Arthroplasty are procedures commonly used in severe degeneration of the knee joint due to osteoarthritis. With an increasing number of Partial or Total Knee Arthroplasty performed in a population that is aging during a time where the amount of healthcare dollars allotted to rehabilitation is declining, there is a need to develop remote monitoring of rehabilitation and to engage and optimize self-management of recovery. Current management of Partial or Total Knee Arthroplasty recovery is typically performed in the out-patient setting and is highly protocol driven. A typical case might be seen by the physical therapist 2-3x/week for 8-10 weeks to perform specific exercises and to monitor progress (i.e. compliance with ROM and strengthening exercises). One recent study suggested that variation in patients' independent exercise and activity after arthroplasty surgery may contribute to variable functional gains. The investigators are proposing that the StepRite device developed by MedHab, (a shoe insert that collects functional data) will reduce cost and improve the efficacy of rehabilitation in total knee arthroplasty patients

Detailed description

Significance of this study The significance of the proposed study includes the projected benefit to the patients in terms of attaining clinical outcomes quicker and to the medical system in terms of managing cost for the provision of services. Subjects are expected to demonstrate improved compliance to patient tailored rehabilitation protocols which will lead to more rapid attainment of clinical outcomes versus present traditional rehabilitation methodologies. The expected level of, and rate of, attainment of clinical outcomes will translate to an overall reduction of cost to the medical system by reducing the need to engage in additional processes or the need to protract the time required to attain clinical outcomes, where either or both in combination can increase rehabilitation expenditures. Objectives To compare the efficacy of StepRite in a prescribed physical therapy program verses traditional in-facility physical therapy program after partial or total knee replacement surgery using validated survey tools to evaluate patient progress, including patient self -reporting of progress and surgeon appraisal of patient performance post-operatively. To compare the overall cost of post-operative rehabilitation of patients involved in traditionally employed regimens versus those using the StepRite device. Hypothesis and specific aims The aim of this study is to evaluate whether improved clinical outcomes as well as reduction in cost in provision of care can be better affected through the use of the Steprite device as compared to the use of traditional rehabilitation modalities. The Investigators will seek to reject the null hypotheses that 1) there is no difference between clinical outcomes attained between patients using the Steprite device and those using traditional rehabilitation modalities and that 2) there is no reduction in cost to the medical system when patients use Steprite versus other conventional methods of rehabilitation. By rejecting the null hypothesis the investigators will accept the alternate hypothesis that, through the use of the Steprite device, not only will patients achieve overall clinical outcomes faster but there will be an associated decrease in cost burden to the medical system and the differences observed will be statistically significant as compared to rehabilitation of patients not using the Steprite device. Patients who use the device post-surgery will demonstrate superior short-term improvements (i.e. 3 months post surgery) with respect to self-reported functional outcomes and gait parameters, compared to a control group not using the device. The patients will self-report through the use of validated survey instruments including the KOOS survey (knee injury and osteoarthritis outcome score), LEFS (lower extremity functional scale) and/or KSS (knee society score), the latter of which includes a section for surgeon evaluation of patient functionality post operatively. Study Design and Methods This is a point of care clinical trial; a trial that functions to integrate research within a clinical setting that has the ability to readily deliver either modality of the proposal. This type of study design relies on provider referral of patients to be approached for consent, after which randomization to one of two treatment groups is facilitated; a control group of 15 patients participating in conventional rehabilitation regimens and an experimental group of 15 patients who will participate in the same rehabilitation regimen but facilitated through the use of Steprite. Importantly, care for patients is delivered as part of current adopted standards utilizing outcome measurements, the use of which and the interpretation of which is already built into care provided by the clinical facility, thereby negating the need to develop additional outcome measures. Recruitment of 30 patients will come from the investigators' normal patient population, among patients who are scheduled for partial or total knee arthroplasty. As there is no change in post op care for these patients from the investigators standard protocols other than monitoring and enforcement of home protocols, the same therapists involved in investigators' normal patient care will be involved with both arms of the study. For this study, 30 patients represents a sample size deemed acceptable as a starting point. There are no other published studies using Steprite in comparative design trials. Determinations of sample size needed for this study, using 80% power and significance of 0.05, incorporate the use of a time frame in days or weeks for completion of the rehabilitation protocols that would allow for the detection of clinically significant differences between the group using Steprite and those using conventional therapies only. Given that conventional therapies can include skilled nursing, home health and outpatient visits and given that the need for each of these is highly variable dependent on the patient, it is difficult to assign a time value for determinations of sample size. With that, a sample size of 30 participants divided into two groups represents an initial starting point, with the potential of incremental addition of more patients in order to achieve significance between the two study groups. Statistical significance will be evaluated utilizing a standard t-test for two group comparison. In preparation for the study, MedHab Inc. will at their expense train all involved investigators and therapists in the fitting and use of the StepRite device. Medhab will also train a lead therapist designated by the lead investigator to be in charge of overseeing and monitoring, ensuring proper use of the device. There is no cost to the patient, hospital or other funding entity for participation in this study. Medhab LLC will assume all costs associated with the training, application, device and use of the StepRite product for the full course of this study. Subjects for this study will be recruited from the patient population seen by the investigator's during the normal course of business. There will be no outside recruitment of individuals or advertising as to the presence or use of the monitoring device to entice new patient referral. Prospective candidates will be asked by the investigator at the time they are designated surgical candidates. All documentation related to the study will be reviewed with the patient by the lead physician or his designee who is appropriately trained in discussing patient recruitment. Final decision and randomization to control or StepRite use will be done as part of the preoperative checkup just prior to surgery where both operative consent and study consent are discussed and signed. Randomization: Once a patient agrees to the study they would be sequentially randomized into whether or not they receive StepRite. The patients will be randomized to every other eligible patient gets the intervention. (ie: 1,3,5,7,9… will get StepRite ; 2,4,6,8 will not get StepRite) 15 Intervention subjects will be recruited and 15 control subjects will be recruited with an extra 5 patients to account for attrition and withdrawals.

Interventions

DEVICESteprite™

Steprite™ Device shoe insert monitoring device

OTHERStandard of care

No Device. Standard of care physical therapy

Sponsors

MedHab, LC
CollaboratorINDUSTRY
Texas Tech University Health Sciences Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
BASIC_SCIENCE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
45 Years to 75 Years
Healthy volunteers
Yes

Inclusion criteria

* Unilateral partial or total knee arthroplasty. * Age 45-75 yr. old * BMI \<35 * Access to Wi-Fi * Have appropriate smart phone and knowledge of use * Be willing to place StepRite app on their personal phone

Exclusion criteria

* History of neuromuscular disorder (e.g. Parkinson's, Polio, or stroke). * Pregnancy * History of cognitive disease that would preclude ability to navigate smart phone

Design outcomes

Primary

MeasureTime frameDescription
Effectiveness of Step Rite Device3 monthsEffectiveness of outcomes with the use of the StepRite device

Countries

United States

Participant flow

Recruitment details

Consented participants

Pre-assignment details

StudyTerminated- device not working

Participants by arm

ArmCount
Active Comparator Steprite™ Device'
steprite™ device active Comparator- The steprite™ System is a monitoring and biofeedback system for the Monitoring of rehabilitation patients Measuring pressure distribution, gait and range of motion of the lower extremities while a patient performs specified rehabilitation exercises Steprite™: Steprite™ Device shoe insert monitoring device
5
Control
Control outcomes with no device. Standard of care physical therapy and outcomes. Standard of care: No Device. Standard of care physical therapy
4
Total9

Baseline characteristics

CharacteristicActive Comparator Steprite™ Device'ControlTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
0 Participants0 Participants0 Participants
Age, Categorical
Between 18 and 65 years
5 Participants4 Participants9 Participants
Partial or Total Knee Arthroplasty5 Participants4 Participants9 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
0 Participants0 Participants0 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
5 Participants4 Participants9 Participants
Race (NIH/OMB)
White
0 Participants0 Participants0 Participants
Sex: Female, Male
Female
2 Participants1 Participants3 Participants
Sex: Female, Male
Male
3 Participants3 Participants6 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 00 / 0
other
Total, other adverse events
0 / 00 / 0
serious
Total, serious adverse events
0 / 00 / 0

Outcome results

Primary

Effectiveness of Step Rite Device

Effectiveness of outcomes with the use of the StepRite device

Time frame: 3 months

Population: Study Terminated due to device not working at our site. No data collected

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026