Skip to content

Evaluation of Directional Recording and Stimulation Using spiderSTN

Evaluation of Directional Recording and Stimulation Using the spiderSTN During the Implantation of DBS Leads

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02894567
Enrollment
6
Registered
2016-09-09
Start date
2016-09-30
Completion date
2017-02-28
Last updated
2017-07-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Essential Tremor, Parkinson's Disease

Brief summary

The purpose of this study is to provide proof-of-concept that directional stimulation and directional recording, in an intraoperative setting, is perceivable in a subject. The tests will be performed using a dedicated intraoperative lead connected to an external neuro-recorder/stimulator, during a deep brain stimulation implantation surgery.

Detailed description

Deep brain stimulation (DBS) technique involves implanting electrodes using a stereotactic method and connecting them to a pulse generator to deliver a current in localized areas in the brain. The optimum location for DBS electrodes is determined by pre-operative brain imaging, often combined with an intraoperative microelectrode recording/stimulating (MER) sequence. Current MER practice involves inserting micro-recording/stimulating electrodes into guide tubes in the brain and lowering them towards the target, performing recordings at selected steps. The recordings differ based on the types of neuronal structures they are passing through.Based on the recordings, some promising locations are further discriminated by stimulation using macro-electrodes, and the target for final lead placement is chosen. The spiderSTN lead (Aleva Neurotherapeutics SA, Switzerland) is capable of recording and stimulating from both its inner and outer surface, allowing the user to steer the direction of stimulation during the target location phase. This will allow the neurosurgeon greater flexibility in investigating the balance between therapeutic benefits and stimulation-induced side effects at a given location. This feasibility study is designed to explore the effect of directional stimulation and the ability to differentiate between stimulation induced side effects at a given location, during the DBS surgery. It will be proposed to patients who suffer from Parkinson disease (PD) or essential tremor (ET) and for whom DBS is indicated according to standard criteria at the hospital. It will be restricted to a limited number of patients (10), sufficient to assess the recording and stimulating capacity of the spiderSTN device. The patient undergoes the normal DBS surgery until the position for the final lead has been chosen. Then the spiderSTN test phase takes place. Once test phase is completed, the conventional DBS surgery resumes.

Interventions

DEVICEIntraoperative test during a deep brain stimulation surgery

The spiderSTN lead is inserted in a selected track in the brain, and is connected to external neuro-recorder/stimulator . Once the intraoperative test phase is completed, the test devices are removed and the DBS surgery resumes.

Sponsors

Aleva Neurotherapeutics SA
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
BASIC_SCIENCE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

Patient foreseen to undergo DBS for Parkinson's disease or Essential Tremor according to routine criteria of the center. For Parkinson Disease: * Person is between 18 and 75 years of age * Established diagnosis of idiopathic Parkinson's disease with progression of symptoms for a minimum of 2 years. * Person has a history of at least 30% improvement on the UPDRS therapy in L-dopa (levodopa), except in the case of tremor dominant patient * Weak control of symptoms by dopaminergic therapy (off phenomenon, fluctuations on / off, dyskinesia on) For Essential Tremor: * Person is between 18 and 80 years of age * Established diagnosis of Essential Tremor for a minimum of 2 years * Functional disability due to tremor was not adequately controlled by medication for at least 3 months prior to implant. Person has given his/her written consent

Exclusion criteria

* Person suffering from an active major psychiatric disorder * Mattis Dementia Rating Scale score \<130 or otherwise not capable of discernment * Presence of major co-morbidity or medical condition that may affect participation to the study * Presence of an electrical or electromagnetic implant (e.g., cochlear implant, pacemaker) * Person with a previous surgery for the treatment of Parkinson's disease or Essential Tremor * Person with a previous brain ablation procedure * Person who suffers from epilepsy * Person who is pregnant: a pregnancy test will be performed in patients of childbearing age * Person with coagulopathies * Abuse of drugs or alcohol

Design outcomes

Primary

MeasureTime frameDescription
Measurement of the delivered electrical current at which a sustained side effect occurs, and compare the results from specific angular directionsup to one hour during surgeryThis will be performed by independently stimulating electrodes which are oriented in different directions on the same spiderSTN lead, and assessing the patient's response.

Secondary

MeasureTime frameDescription
Measurement of the electrical current created by the neuronal activity coming from specific directions, and compare the results.up to one hour during surgeryTo assess the recording capabilities of the spiderSTN lead by correlating the results obtained from the neurologist's visual, real-time interpretation of the recorded neuronal activity, to a post-processing analysis of the actual signal recorded.
Electrical functionality of the study device during the test phase1 dayThe electrical integrity of the device will be measured before and after the test phase, to confirm that it was functional throughout the test phase.

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026