Qualitative Radionuclide Shuntography for Adult Patients With Suspected V-P Shunt Malfunction

Clinical Value of Radionuclide Shuntography by Qualitative Methods in Hydrocephalic Adult Patients With Suspected Ventriculoperitoneal Shunt Malfunction

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02894216
Enrollment
69
Registered
2016-09-09
Start date
2016-04-30
Completion date
2017-04-30
Last updated
2017-05-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Radionuclide Shuntography, Ventriculoperitoneal Shunt Malfunction

Brief summary

The investigators retrospectively reviewed all radionuclide shuntographic tests using (99m)technetium-pertechnetate (DTPA) performed between August 2005 and December 2015 in nuclear medicine department of Far Eastern Memorial Hospital. The results of shuntography were evaluated visually and qualitatively, and correlated with clinical follow-up. The tests were interpreted as normal and abnormal, including complete distal obstruction, partial distal obstruction or miscellaneous. Clinical outcomes within 30 days were defined based on subsequent need for revision, re-implantation or adjustment of shunt pressure. Then the investigators calculated the sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and overall accuracy.

Detailed description

Introduction: Cerebrospinal fluid ventriculoperitoneal (V-P) shunts are often used in the treatment of hydrocephalus. Complications from shunts are not uncommon and can present with a variety of signs and symptoms, which could be evaluated by clinical examination and neuro-imaging. The radionuclide cerebrospinal fluid (CSF) shunt study provides a simple, effective, and low-radiation-dose method of assessing CSF shunt patency. When a discrepancy between neurological examination and imaging, additional radionuclide shuntography can be helpful. The purpose of the study was to analyze in the imaging findings and clinical interpretation of a variety of shuntography results and to determine the applicability of shuntography in patients with suspected shunt malfunction. Materials and Methods: The investigators include all radionuclide shuntographic tests using (99m)technetium-pertechnetate (DTPA) performed between August 2005 and December 2015 in our department. No complications or discomfort were noted in the examinations. The results of shuntography were evaluated visually and qualitatively, and correlated with clinical follow-up. The tests were interpreted as normal and abnormal, including complete distal obstruction, partial distal obstruction or miscellaneous. Clinical outcomes within 30 days were defined based on subsequent need for revision, re-implantation or adjustment of shunt pressure. Then the investigators calculated the sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and overall accuracy. The investigators would also determine the correlation with operative findings and assessment of radionuclide shuntography.

Interventions

PROCEDUREradionuclide shuntography

the investigators retrospectively enrolled patient who received radionuclide shuntography

Sponsors

Far Eastern Memorial Hospital
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* all radionuclide shuntographic tests using (99m)technetium-pertechnetate (DTPA) performed between August 2005 and December 2015 in nuclear medicine department in Far Eastern Memorial Hospital

Exclusion criteria

* patients younger than 21 years old

Design outcomes

Primary

MeasureTime frameDescription
clinical outcome30 days post radionuclide shuntographysubsequent need for revision, re-implantation or adjustment of shunt pressure.

Secondary

MeasureTime frameDescription
surgical findings30 days post radionuclide shuntographyfindings (obstruction or not) noted by surgery

Other

MeasureTime frameDescription
Safety and Tolerability - Number of participants with treatment-related adverse events30 days post radionuclide shuntographyNumber of participants with treatment-related adverse events