Skip to content

Comparing the Safety and Efficacy of Paclitaxel Controlled Release Balloon Catheter in the Treatment of In-stent Restenosis of Coronary Artery Lesion With Paclitaxel Release Coronary Balloon Catheter

A Multicenter, Prospective and Randomized Controlled Clinical Study (VasoguardTM Trial II) That Comparing the Safety and Efficacy of Paclitaxel Controlled Release Balloon Catheter (VasoguardTM) in the Treatment of In-stent Restenosis of Coronary Artery Lesion With Paclitaxel Release Coronary Balloon Catheter (SeQuent Please)

Status
UNKNOWN
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02891018
Enrollment
260
Registered
2016-09-07
Start date
2015-12-31
Completion date
Unknown
Last updated
2016-09-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

In-stent Restenosis

Brief summary

Study purpose The safety and efficacy of paclitaxel controlled release balloon catheter Vasoguard TM in treatment of in-stent restenosis. Study group Experimental group: paclitaxel controlled release balloon catheter Vasoguard TM Control group: paclitaxel release coronary balloon catheter SeQuent Please

Interventions

DEVICEpaclitaxel controlled release balloon catheter Vasoguard TM
DEVICEpaclitaxel release coronary balloon catheter SeQuent Please

Sponsors

Fudan University
CollaboratorOTHER
Shandong Branden Med.Device Co.,Ltd
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

\- Subject need 18 to 80 years of aged male or non-pregnant women; Subject has stable anina pectoris, or unstable anina pectoris, or old myocardial infarction patients, or ischemia with evidence but without symptom; Subject has a life expectancy of more than 2 years; Subject occurred restenosis after vessel lesion in situ receiving the first stent operation; In-stent restenosis type Mehran I, II, III, IV, reference vessel diameter of 1.5-4.0 mm, length of 40 mm or less; Target lesion stenosis must be equal or greater than 70% or 50% and with evidence of ischemia; Single or two coronary small vessel lesions in situ; Other lesion which need interventional treatment must be away from target lesion at least 10 mm; Subject can understand the trail purpose, sign informed consent voluntarily, agree to accept clinical telephone follow-up and angiographic follow-up at 9 months; Target lesion can be pre-expanded successfully (Guide wire can get through lesion, balloon pre-expand the remnant stenosis of vessel lumen is less or equal to 50%, without current limiting interlayer and thrombosis).

Exclusion criteria

\- Patient that in the opinion of the investigator is not appropriate for this trail; Pregnancy and lactation female patients; Patient has a life expectancy of less than 2 years; Severe congestive heart failure or NYHA IV heart failure; Patient who have bleeding constitution, cannot use anticoagulation and antiplatelet drugs; Patient that happened acute myocardial infarction within a week; Patient who happened stroke within six months; Patient who with severe renal failure (GFR≤30ml/min); Patient who had received heart transplantation; Patient who cannot tolerate aspirin and / or P2Y12 receptor inhibitor drugs; Patient who has allergy to paclitaxel, PLGA or contrast agent; Peptic ulcer or gastrointestinal bleeding within the prior 6 months. Patients who are participating in another drug or device clinical trail, which have not completed the primary endpoint follow- up period. Angiographic relevant: Three or more coronary artery vessel lesion; Target vessel has extensive thrombosis evidence; Restenosis of vein graft after bypass surgery; Left main coronary artery and ostial lesion within 2mm; Target lesion proximal exist seriously distorted or severe calcified lesion.

Design outcomes

Primary

MeasureTime frame
Late Lumen Lossat 9 months

Secondary

MeasureTime frame
Operation Success Rateat 9 months
Target lesion in-segment rate after operation 9 monthsat 9 months
Device Success Rateat 9 months
Major adverse cardiovascular events (MACE) related with device, include cardiac death, myocardial infarction of target vessel and target lesion revascularization (TLR) by clinical-drivenat 9 months
Thrombotic events incidence (ARC definition include deterministic thrombosis, possible thrombosis and not eliminating thrombosis; point-in-time include acute within 24h, subacute between 2 and 30 d and later period over 30 d)at 9 months
Target lesion revascularization (TLR) and Target vessel revascularization (TVR) by clinical-drivenat 9 months

Countries

China

Contacts

Primary ContactYuxia Yin
yinyx@brandentech.com18596253015

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026