Skip to content

Evaluation of Vision Effects of a Cosmetic Tinted Hydrogel Contact Lens

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02886923
Enrollment
24
Registered
2016-09-01
Start date
2016-08-01
Completion date
2017-01-23
Last updated
2019-12-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Refractive Error

Brief summary

Subjects will wear 2 of 2 study contact lenses for a wearing time of approximately three to four hours at each of the visits in order to take measurements on binocular functional visual performance.

Interventions

DEVICEHioxifilcon A Test

contact lens made with hioxifilcon A material

DEVICEHioxifilcon A With Cosmetic Ring Control

contact lens made with hioxifilcon A material with a cosmetic ring on the lens

Sponsors

Johnson & Johnson Vision Care, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
35 Years to 42 Years
Healthy volunteers
Yes

Inclusion criteria

1. The subject must read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form. 2. The subject must appear able and willing to adhere to the instructions set forth in this clinical protocol. 3. The subject must be between 35 and 42 years of age (inclusive). 4. The subject's vertex corrected spherical equivalent distance refraction must be in the range of -6.00 Diopters (D) to +4.00 D in each eye. 5. The subject's refractive cylinder must be ≤ 0.75 D in each eye. 6. The subject must have best corrected visual acuity of 20/30 or better in each eye. 7. The subject must be an adapted soft contact lens wearer in both eyes (defined as a minimum of 6 hours of Daily Wear (DW) for a minimum of 1 month prior to the study). 8. The subject must have normal eyes (i.e., no ocular medications or infections of any type).

Exclusion criteria

1. Currently pregnant or lactating (subjects who become pregnant during the study will be discontinued). 2. Any ocular or systemic allergies or diseases that may interfere with contact lens wear. 3. Any infectious disease (e.g., hepatitis, tuberculosis) or a contagious immunosuppressive disease (e.g., HIV) by self-report. 4. Clinically significant (grade 3 or 4) corneal edema, corneal vascularization, corneal staining, or any other abnormalities of the cornea which would contraindicate contact lens wear. 5. Clinically significant (grade 3 or 4) tarsal abnormalities or bulbar injection which might interfere with contact lens wear. 6. Any ocular infection. 7. Any previous, or planned, ocular or interocular surgery (e.g., radial keratotomy, photorefractive keratectomy (PRK), laser-assisted in situ keratomileusis (LASIK), etc.) 8. Any corneal distortion resulting from previous hard or rigid gas permeable contact lens wear. 9. Habitual contact lens type is toric, bifocal, in monovision contact lens wear, or is worn as extended wear. 10. Participation in any contact lens or lens care product clinical trial within 30 days prior to study enrollment. 11. Employee of investigational clinic (e.g., Investigator, Coordinator, Technician)

Design outcomes

Primary

MeasureTime frameDescription
The Binocular Functional Visual Performance Under Distance Day Time Conditions (250 cd/m2) for Centrally Presented High Contrasts (HC) Time Controlled Visual Acuity (TCVA) Targets.15 minutes post lens fitTime Controlled Visual Acuity (TCVA) was assessed at 4 m using 250 cd/m2 luminance. The luminance requirements were same at the target and at the eye. Binocular functional visual performance was measured for the centrally presented high contrasts targets.

Secondary

MeasureTime frameDescription
The Binocular Functional Visual Performance Under Distance Night Time Conditions (2.5 cd/m2) for Centrally Presented HC TCVA Targets.15 Minutes post lens fittingTime Controlled Visual Acuity (TCVA) was assessed at 4 m using 2.5 cd/m2 luminance. The luminance requirements were same at the target and at the eye. Binocular functional visual performance was measured for the centrally presented high contrasts targets.
The Binocular Functional Visual Performance Under Intermediate Vision Indoor Conditions (50 cd/m2) for Centrally Presented HC TCVA Targets.15 Minutes post lens fittingTime Controlled Visual Acuity (TCVA) was assessed at 67 cm using 50 cd/m2 luminance. The luminance requirements were same at the target and at the eye. Binocular functional visual performance was measured for the centrally presented high contrasts targets.

Countries

United Kingdom

Participant flow

Recruitment details

A total of 24 subjects were enrolled into this study. Of the enrolled subjects 23 were dispensed a study lens while 1 subject failed to meet all eligibility criteria. Of the dispensed subjects, all 23 completed the study.

Participants by arm

ArmCount
Dispensed Subjects
All subjects that were dispensed a study lens.
23
Total23

Baseline characteristics

CharacteristicDispensed Subjects
Age, Continuous38.0 Years
STANDARD_DEVIATION 2.57
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
2 Participants
Race (NIH/OMB)
Black or African American
5 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
2 Participants
Race (NIH/OMB)
White
14 Participants
Region of Enrollment
United Kingdom
23 Participants
Sex: Female, Male
Female
15 Participants
Sex: Female, Male
Male
8 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 230 / 23
other
Total, other adverse events
0 / 230 / 23
serious
Total, serious adverse events
0 / 230 / 23

Outcome results

Primary

The Binocular Functional Visual Performance Under Distance Day Time Conditions (250 cd/m2) for Centrally Presented High Contrasts (HC) Time Controlled Visual Acuity (TCVA) Targets.

Time Controlled Visual Acuity (TCVA) was assessed at 4 m using 250 cd/m2 luminance. The luminance requirements were same at the target and at the eye. Binocular functional visual performance was measured for the centrally presented high contrasts targets.

Time frame: 15 minutes post lens fit

Population: All subjects who had successfully completed all required visits without any protocol deviations that the study responsible clinician documented as impacting the assessment of the hypotheses.

ArmMeasureValue (MEAN)Dispersion
Hioxifilcon A (Test)The Binocular Functional Visual Performance Under Distance Day Time Conditions (250 cd/m2) for Centrally Presented High Contrasts (HC) Time Controlled Visual Acuity (TCVA) Targets.-0.03 -10 x logMARStandard Deviation 0.754
Hioxifilcon A (Control)The Binocular Functional Visual Performance Under Distance Day Time Conditions (250 cd/m2) for Centrally Presented High Contrasts (HC) Time Controlled Visual Acuity (TCVA) Targets.0.33 -10 x logMARStandard Deviation 0.656
Secondary

The Binocular Functional Visual Performance Under Distance Night Time Conditions (2.5 cd/m2) for Centrally Presented HC TCVA Targets.

Time Controlled Visual Acuity (TCVA) was assessed at 4 m using 2.5 cd/m2 luminance. The luminance requirements were same at the target and at the eye. Binocular functional visual performance was measured for the centrally presented high contrasts targets.

Time frame: 15 Minutes post lens fitting

Population: All subjects who had successfully completed all required visits without any protocol deviations that the study responsible clinician documented as impacting the assessment of the hypotheses.

ArmMeasureValue (MEAN)Dispersion
Hioxifilcon A (Test)The Binocular Functional Visual Performance Under Distance Night Time Conditions (2.5 cd/m2) for Centrally Presented HC TCVA Targets.-2.16 -10 x logMARStandard Deviation 0.606
Hioxifilcon A (Control)The Binocular Functional Visual Performance Under Distance Night Time Conditions (2.5 cd/m2) for Centrally Presented HC TCVA Targets.-1.69 -10 x logMARStandard Deviation 0.727
Secondary

The Binocular Functional Visual Performance Under Intermediate Vision Indoor Conditions (50 cd/m2) for Centrally Presented HC TCVA Targets.

Time Controlled Visual Acuity (TCVA) was assessed at 67 cm using 50 cd/m2 luminance. The luminance requirements were same at the target and at the eye. Binocular functional visual performance was measured for the centrally presented high contrasts targets.

Time frame: 15 Minutes post lens fitting

Population: All subjects who had successfully completed all required visits without any protocol deviations that the study responsible clinician documented as impacting the assessment of the hypotheses.

ArmMeasureValue (MEAN)Dispersion
Hioxifilcon A (Test)The Binocular Functional Visual Performance Under Intermediate Vision Indoor Conditions (50 cd/m2) for Centrally Presented HC TCVA Targets.-1.29 -10 x logMARStandard Deviation 0.673
Hioxifilcon A (Control)The Binocular Functional Visual Performance Under Intermediate Vision Indoor Conditions (50 cd/m2) for Centrally Presented HC TCVA Targets.-1.04 -10 x logMARStandard Deviation 0.782

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026