Skip to content

Pneumacare SLP Validation in Infants and in Clinical Bronchiolitis

Pneumacare SLP Validation in Infants and in Clinical Bronchiolitis: Validation of Structured Light Plethysmography (SLP) in Healthy Infants and in Infants With Clinical Bronchiolitis

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02881632
Enrollment
60
Registered
2016-08-29
Start date
2015-11-30
Completion date
2016-03-31
Last updated
2016-08-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bronchiolitis

Brief summary

A cohort observational study to characterise baseline Structured Light Plethysmography (SLP) outputs in infants with bronchiolitis and examine response to treatment using the Thora3DiTM

Detailed description

Viral illness, particularly chest infection causing breathing difficulty in infants and children is the commonest reason for admission to hospital. At present, there are no objective measurements of the degree of breathing difficulty. This is because current objective tests of breathing difficulty requires the patient to cooperate and actively perform the tests. This is not possible in babies and very challenging in young children. SLP is a noncontact, effort independent technique for measuring the rate of breathing, the amount of chest expansion and the relative contribution of chest and abdomen to the work of breathing. Measuring these parameters which are known to vary with increasing breathing difficulty will allow us to make objective assessments of breathing difficulty. This study proposes to validate this technique in babies aged 02 years who are healthy and in babies with clinical viral bronchiolitis. The Investigators intend to demonstrate that the technique is feasible in this young age group and that the investigators will be able to demonstrate clinically valid differences between normal and ill babies and also demonstrate measurable differences with the evolution of the clinical illness.

Interventions

DEVICEStructured Light Plethysmography (SLP) - Pneumscan

Both healthy infants and bronchiolitis infants will have their chest movements monitored using Structured Light Plethysmography (SLP) performed by a device (Thora-3 Di) using a projector and two cameras. A light pattern of black and white squares is projected on the child's chest and the cameras record how the shape of this pattern changes with breathing. A computer converts this information to show how the child's chest moves during breathing.

Sponsors

Pneumacare Ltd
CollaboratorINDUSTRY
University Hospitals of North Midlands NHS Trust
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Minutes to 2 Years
Healthy volunteers
Yes

Inclusion criteria

* Aged between 0 and 1 years * Doctor diagnosis of AVB * Admitted to hospital within last 24hrs (AVB participants only) * Or healthy term infant aged up to 2yrs with no current respiratory illness

Exclusion criteria

* Patients with significant co morbidities resulting in clinical instability (assessed by the clinician at screening only): * An acute or chronic condition that, in the investigator's opinion, would limit the patient's ability to participate in the study * Parents unable to consent/comply with trial protocol * An inpatient for over 24hrs (AVB patients only)

Design outcomes

Primary

MeasureTime frameDescription
Difference in SLP measurements between infants.Measured upto 7 daysDifference in SLP measurements between infants. SLP provides a measure of the chest and abdominal movement (Respiratory effort) of the subjects, the movement signal will be used to quantify clinically relevant tidal breathing parameters such as timing indices: Ti (Time of inspiration), Te ( Time of expiration) and Ttot (Ti+Te). Parameters will be quantified for each recorded SLP signal (averaged) from each infant, and then used to compare between infants with bronchiolitis and healthy babies.

Secondary

MeasureTime frameDescription
Changes in SLP measurements in infants during their clinical course.Measured upto 7 daysChanges in SLP measurements in infants during their clinical course in hospital. SLP provides a measure of the chest and abdominal movement (Respiratory effort) of the subjects, the movement signal will be used to quantify clinically relevant tidal breathing parameters such as timing indices: Ti (Time of inspiration), Te ( Time of expiration) and Ttot (Ti+Te). For each subject SLP was recorded on a daily basis, this will allow the comparison between the parameters within subject to check the progression of the disease with time
Changes in SLP measurements in infants given additional breathing support.Measured upto 7 daysChanges in SLP measurements in infants during their clinical course in hospital who are given additional breathing support. SLP provides a measure of the chest and abdominal movement (Respiratory effort) of the subjects, the movement signal will be used to quantify clinically relevant tidal breathing parameters such as timing indices: Ti (Time of inspiration), Te ( Time of expiration) and Ttot (Ti+Te). For each subject SLP was recorded on a daily basis, this will allow the comparison between the parameters within subject to check the progression of the disease with time.

Countries

United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026