Skip to content

OCT Based Edge and In-stent Vascular Response After Cordimax Stent in patIents With NSTE-ACS

Optical Coherence tOmography Based Edge and In-stent Vascular Response After a Novel bioDegradable Polymer sIrolimus-eLuting Stent in patIents With Non-ST Elevation acuTe Coronary sYndrome (NSTE ACS)

Status
UNKNOWN
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02868203
Enrollment
80
Registered
2016-08-16
Start date
2016-08-31
Completion date
2020-08-31
Last updated
2016-08-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Angina, Unstable, Non-ST-Segment Elevation Myocardial Infarction

Brief summary

This study evaluates the completeness of strut coverage and vessel wall response, at different time points (3-6-12 Months), following CordimaxTM stent implantation in patients with non-ST elevation acute coronary syndrome

Detailed description

Major concerns were addressed to the delayed healing process of drug-eluting stents . To date no studies have detailed the in-vivo completeness of CordimaxTM stent coverage at different time points. The objective of this prospective study is to measure the completeness of strut coverage and vessel wall response (neointima disomogeneity, acquired late incomplete strut apposition) at different time points following CordimaxTM stent implantation, in patients with non-ST elevation acute coronary syndrome . Optical Coherence Tomography (OCT) that detects smaller degrees of stent strut coverage more accurately than IVUS will be used at different time points (3-6-12 Months)

Interventions

DEVICEOCT

OCT after stent implantation

DEVICEeLuting stent

Sponsors

Xijing Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

1. age ≥18 and ≤ 75 years 2. Non-ST-segment elevation MI 3. Patient willing to comply with specified follow-up 5.Patient or legally authorized representative has been informed of the nature of the study, agrees to its provisions and has been provided written informed consent 6.Single or two de novo or non-stented restenotic lesion in a native coronary artery 7. Target lesion to be covered by a single stent of max 30 mm . Reference vessel diameter ≥2.25 to ≤ 4.0 mm by visual estimate 8. The vessel diameter should be measured after pre-dilation procedure and after intra-coronary nitroglycerin if spasm is suspected 9. Target lesion ≥70% stenosed by visual estimate

Exclusion criteria

1. Pregnant or nursing patients and those who plan pregnancy in the period up to 1 year following index procedure. Female patients of childbearing potential must have a negative pregnancy test done within 7 days prior to the index procedure per site standard test 2. Impaired renal function or on dialysis 3. Platelet count \<100,000 cells/mm3 or \>700,000 cells/mm3 or a WBC\<3,000 cells/mm3 4. Patient has a history of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated 5. Patient requires low molecular weight heparin (LMWH) treatment postprocedure or has received a dose of LMWH ≤8 hours prior to index procedure 6. Patient has received any organ transplant or is on a waiting list for any organ transplant; 7. Patient has other medical illness or known history of substance abuse that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (\<1 year) 8. Patient has a known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel/ticlopidine, prasugrel, stainless steel alloy, sirolimus and/or contrast sensitivity that cannot be adequately pre-medicated 9. Patient has previously received murine therapeutic antibodies and exhibited sensitization through the production of Human Anti-Murine Antibodies 10. Patient presents with cardiogenic shock 11. Patient has extensive peripheral vascular disease that precludes safe 6 French sheath insertion; 12. Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study 13. Currently participating in another investigational drug or device study or patient in inclusion in another investigational drug or device study during follow-up 14. Calcified target lesion(s) which cannot be successfully predilated 15. Target lesion has excessive tortuosity unsuitable for stent delivery and deployment;

Design outcomes

Primary

MeasureTime frame
Proportion of uncovered and/or malapposed bioDegradable polymer sIrolimus-eLuting stent at 12 month after the implant, as measured by OCT12 month

Contacts

Primary Contactling tao, doctor
lingtao@fmmu.edu.cn86-29-84775183

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026