Transpulmonary Pressure and Airway Pressure Release Ventilation (APRV).

Incidence of High Levels of Transpulmonary Pressure During the Use of Airway Pressure Release Ventilation.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02866513
Enrollment
20
Registered
2016-08-15
Start date
2016-02-29
Completion date
2017-03-31
Last updated
2017-11-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Patient Mechanically Ventilated With APRV Mode

Brief summary

Mechanical ventilation can induce pulmonary lesions called ventilator induced lung injury (VILI). High levels of Transpulmonary pressure is one of the most important mechanism of VILI during the use of mechanical ventilation. The use of bilevel pressure ventilator modes like APRV could generate high levels of transpulmonary pressure. The aim of this study is to evaluate the variations of transpulmonary pressure during the use of APRV by clinicians

Interventions

OTHERevaluate the variations of transpulmonary pressure during the use of APRV by clinicians.

Sponsors

Assistance Publique Hopitaux De Marseille
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult * Patient mechanically ventilated for more than 48 H for acute respiratory failure * Decision to use of the APRV mode by clinicians in charge of the patient

Exclusion criteria

\- Contraindication for the use of a nasogastric tube

Design outcomes

Primary

MeasureTime frameDescription
Transpulmonary pressure24 hoursMeasurement of transpulmonary pressure needs the measurement of oesophageal pressure with a specific nasogastric tube. This measurement is now available in routine in few mechanical ventilators in intensive care units (eg: AVEA Ventilator. Vyasys HealthCare). Transpulmonary pressure is the difference between airway pressure and oesophageal pressure and it is now easy to obtain and monitor at the bedside with these ventilators. It is also possible to record the value furthermore than 24 hours.

Secondary

MeasureTime frameDescription
Maximal value of transpulmonary pressure24 hoursValue of tidal volume \> 8 ml/kg