To Compare the Efficacy Between 3 Fetal Monitoring Methods (EUM)

A Prospective, Blinded Clinical Study to Compare the Efficacy Between Three Fetal Monitoring Methods: Electro Uterine Monitor (EUM), Fetal Doppler and Scalp Electrode

Status
UNKNOWN
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02864225
Enrollment
400
Registered
2016-08-11
Start date
2016-09-30
Completion date
2019-09-30
Last updated
2016-08-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fetal Heartbeat Tracings

Brief summary

Background: Identification and measurement of fetal heart tracings throughout pregnancy and labor is crucial to the well-being of the fetus. Non reassuring fetal heart rate is one of the most common indications for operative vaginal delivery or cesarean section. Therefore, management of labor requires reliable and accurate information about fetal heart rate. In most normal spontaneous labors, fetal heart rate is characterized by the baseline heart rate (from 110 to 160 beats per minute), variability (beat to beat changes) and periodic changes (accelerations or decelerations). In each stage of labor the tracing may have different characteristics, with variable decelerations much more common at the end of the second stage of labor. Objective: To Show non inferiority of the EUM to the fetal doppler and scalp electrode by comparing the reliability and accuracy of the EUM versus fetal doppler compared to scalp electrode in the same patients.

Detailed description

Background: Identification and measurement of fetal heart tracings throughout pregnancy and labor is crucial to the well-being of the fetus. Non reassuring fetal heart rate is one of the most common indications for operative vaginal delivery or cesarean section. Therefore, management of labor requires reliable and accurate information about fetal heart rate. In most normal spontaneous labors, fetal heart rate is characterized by the baseline heart rate (from 110 to 160 beats per minute), variability (beat to beat changes) and periodic changes (accelerations or decelerations). In each stage of labor the tracing may have different characteristics, with variable decelerations much more common at the end of the second stage of labor. Objective: To Show non inferiority of the EUM to the fetal doppler and scalp electrode by comparing the reliability and accuracy of the EUM versus fetal doppler compared to scalp electrode in the same patients. METHODS The current method for detecting fetal heart rate is fetal Doppler, which is routinely used in practically all labors, is based on the Doppler technology of detecting heart valves motion and blood velocity. The fetal Doppler transducer is placed on the abdomen of the parturient and is susceptible to positional changes of the parturient. Moreover, among obese gravidas, fetal heart rate tracings via external fetal Doppler may be difficult to achieve. Another method for monitoring fetal heart rate is the scalp electrode which is attached to the fetal scalp and records the heart rate patterns. This method is invasive and can be used only after the amniotic membranes are ruptured. Monitoring with scalp electrode is superior to the fetal Doppler as it is direct and non-affected by maternal position. However, it is an invasive method and may contribute to the development fever during or after labor.

Interventions

DEVICEScalp electrode,

the parturient will be connected to the routine fetal Doppler and to the EUM. and When necessary to the scalp electrode will be connected. Tracings will be recorded simultaneously from all three devices until delivery. three separate outputs will be processed Output of the scalp electrode recording. Output of the fetal doppler. Output of the EUM. Three noncontinuous segments of 30 minutes each with two segments occurring during the first stage of labor and the third occurring during the second stage of labor, will be randomly picked from the scalp electrode recording with 3 matching segments in time from the EUM100pro and the fetal doppler

DEVICEFetal doppler

the parturient will be connected to the routine fetal Doppler and to the EUM. and When necessary to the scalp electrode will be connected. Tracings will be recorded simultaneously from all three devices until delivery. three separate outputs will be processed Output of the scalp electrode recording. Output of the fetal doppler. Output of the EUM. Three noncontinuous segments of 30 minutes each with two segments occurring during the first stage of labor and the third occurring during the second stage of labor, will be randomly picked from the scalp electrode recording with 3 matching segments in time from the EUM100pro and the fetal doppler

DEVICEEUM

the parturient will be connected to the routine fetal Doppler and to the EUM. and When necessary to the scalp electrode will be connected. Tracings will be recorded simultaneously from all three devices until delivery. three separate outputs will be processed Output of the scalp electrode recording. Output of the fetal doppler. Output of the EUM. Three noncontinuous segments of 30 minutes each with two segments occurring during the first stage of labor and the third occurring during the second stage of labor, will be randomly picked from the scalp electrode recording with 3 matching segments in time from the EUM100pro and the fetal doppler

Sponsors

Tel-Aviv Sourasky Medical Center
Lead SponsorOTHER_GOV

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
DOUBLE (Caregiver, Outcomes Assessor)

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

1. Clinical indication to insert a scalp electrode for fetal heart rate tracing. 2. Maternal age \>18 years 3. Reactive fetal heart rate monitoring and BPP 8/8 at enrollment 4. Singleton pregnancy 5. No fetal abnormality or chromosomal defect 6. Subjects are willing and able to comply with the requirements of the protocol. 7. Fully understand all elements of, and have signed and dated, the written informed consent form before initiation of protocol-specified procedures, when VAS \<3.

Exclusion criteria

1. Women who refused to sign the informed consent form. 2. Maternal age \< 18 years. 3. Multiple pregnancy 4. Woman with implanted electronic device of any kind 5. Woman with allergic to silver. 6. Irritated skin or open wound

Design outcomes

Primary

MeasureTime frameDescription
The difference between the fetal scalp electrode tracings and the EUM tracings of the fetal heart activity.Up to 72 hoursMean Positive Percent Agreement (PPA) for interpretable/un interpretable traces (between EUM, scalp electrode and fetal doppler).
ReliabilityUp to 72 hoursMean sensitivity for individual tracing identification (between EUM, scalp electrode and fetal doppler)

Contacts

Primary ContactYariv Yogev, professor
yarivy@tlvmc.gov.il052-7360616

Outcome results

None listed