Frequency Doubling Technology (FDT) Mobile Visual Field Testing

Evaluation of Different Frequency Doubling Technology (FDT) Mobile Devices for Visual Field Assessment

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02862158
Enrollment
500
Registered
2016-08-10
Start date
2016-08-31
Completion date
2022-11-30
Last updated
2020-10-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glaucoma

Brief summary

This is a single center, prospective study to evaluate the efficacy and reproducibility of frequency doubling technology (FDT)-based visual field devices compared to conventional Humphrey Visual Field (HVF) perimetry. The investigators plan to enroll 500 patients in this study.

Detailed description

Glaucoma is a leading cause of irreversible and preventable blindness world-wide. Insufficient evidence exists to support routine screening for glaucoma in a primary care setting due to the relatively low prevalence of the disease (Guirguis-Blake, 2005 and Moyer, 2013). Frequency doubling technology (FDT)-based perimetry is a relatively inexpensive and portable visual field testing device with a short testing time that has shown reasonable efficacy, sensitivity and specificity in screening for glaucoma in clinic- and community-based settings (Mansberger, 2005 and Nomoto 2009). The aim of our study is to compare the efficacy and reproducibility of FDT perimetry platforms compared with Humphrey Visual Field (HVF) perimetry (which is the gold clinical standard in clinics and hospitals) in detecting glaucomatous visual field defects.

Interventions

DEVICEFDT visual field
DEVICEStandard HVF

Sponsors

University of Miami
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients (18 and over) who speak English, Spanish or Creole, and are capable of providing informed consent and who have a Humphrey Visual Field (HVF) test within the prior the 6 months preceding enrollment are eligible for enrollment in this non-invasive study. Patients will be recruited from among patients at the Bascom Palmer Eye Institute clinics during their regularly scheduled clinic visits. No advertising will be used to recruit patients.

Exclusion criteria

* Adults unable to consent, individuals who are not yet adults (infants, children and teenagers), pregnant women and prisoners and other vulnerable populations will be excluded from the study.

Design outcomes

Primary

MeasureTime frameDescription
Pattern of visual field loss in FDT visual fields as compared with standard HVFThe investigators anticipate to enroll the subjects over a period of 12 months. The estimated time required for data analysis is 6 months following enrollment of all subjects.Visual Field

Secondary

MeasureTime frameDescription
Mean deviation (MD) in FDT visual fields as compared with standard HVFThe investigators anticipate to enroll the subjects over a period of 12 months. The estimated time required for data analysis is 6 months following enrollment of all subjects.Visual Field
Pattern standard deviation (PSD) in FDT visual fields as compared with standard HVFThe investigators anticipate to enroll the subjects over a period of 12 months. The estimated time required for data analysis is 6 months following enrollment of all subjects.Visual Field