Skip to content

Bespoke vs Standard Instrumentation in TKR

Randomised Controlled Trial of Patient Specific Instrumentation vs Standard Instrumentation in Total Knee Arthroplasty

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02845206
Enrollment
172
Registered
2016-07-27
Start date
2016-02-01
Completion date
2020-02-02
Last updated
2024-09-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Knee Osteoarthritis

Keywords

Total Knee Replacement, Patient Specific Instrumentation

Brief summary

Total knee replacement (TKR) is an established treatment for knee osteoarthritis and leads to a satisfactory outcome in over 75% of patients. The pain and function after TKR can be dependent on the accuracy of initial implantation, as deviation of more than 3 degrees from the normal alignment of the limb can lead to abnormal stresses on the implant and accelerated failure. Patient specific cutting blocks may result in a more individualised implant placement, improved pain and function following surgery, and a long-lasting implant. This trial is designed to investigate if there is any benefit to bespoke instrumentation in terms of pain and function to the patient, and an economic benefit to the NHS.

Detailed description

Total knee replacement (TKR) is an established treatment for 'wear and tear' arthritis and leads to a satisfactory outcome in over 75% of patients. However, this means that up to 25% of patients are not entirely satisfied with their TKR. The longevity and stability of a TKR is greatly dependent on the accuracy of the initial surgery. Deviation of more than 3 degrees from the normal axis can lead to abnormal stresses causing the implants to fail. 'Patient specific' technology involves preoperative computer assessment of the patients' knee and allows for a 'patient specific' cutting block to be manufactured. This will allow for individual bony cuts specific to the patients own anatomy. 'Patient specific' implants and cutting blocks may allow a more optimal implant positioning and are implanted without the need for instrumentation of the femoral medullary canal (thigh), so lower blood loss may result. This could result in improved early range of movement and decreased pain following surgery. The total knee replacement used in this study will be the GMKSphere (Medacta International) TKR. It has a specific design which more closely resembles a natural unreplaced knee than any other knee replacement. It may help address the phenomenon of 'mid flexion instability', which is where the patient perceives their replaced knee to be unsteady on stairs and slopes. Patient specific technology may also result in a cost saving, as it potentially reduces the number of sterilised trays required during the surgery. This study will allow for comparison in knee function and patient outcomes between patients who have undergone their TKR with patient specific cutting blocks compared to conventional cutting blocks. The scans obtained following the surgery could lead to world leading methodology for the assessment of knee replacements and would set a blue print for the evaluation of other knee implants in the future.

Interventions

PROCEDUREPatient specific cutting blocks

'MyKnee' Instrumentation

PROCEDUREConventional cutting blocks

Standard Instrumentation

Sponsors

NHS Lothian
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patients with osteoarthritis ('wear and tear') of the knee which is sufficiently symptomatic to require knee arthroplasty as assessed by their consultant orthopaedic surgeon

Exclusion criteria

* Patients with inflammatory arthropathy, patients requiring bone augmentation, ligament incompetence, values deformity \> 5 degrees

Design outcomes

Primary

MeasureTime frameDescription
Limb alignment1 yearsMeasured in degrees from Hip-Knee-Ankle radiographs from centre of femoral head to midpoint of the ankle

Secondary

MeasureTime frameDescription
Difference between baseline pre-op and one year post-op change in gait measured using a bespoke clinic-appropriate motion analysis system.1 yearKnee range of motion, strength and gait analysis assessments will be carried out on a bespoke clinic-appropriate motion analysis system. This system consists of 8 Vicon B10 Bonita cameras (Vicon Systems, Oxford) which immediately surround a self-paced N-Mill treadmill (Motekforce Link, Amsterdam).
Difference in patient reported knee pain level as measured by Oxford Knee Score between baseline and one year and also between study groups.1 yearValidated patient reported knee pain questionnaires as measured by Oxford Knee Score (out of 48 points) pre-operation and at one year post-operation. Difference between baseline and one year scores for each patient and also analysed between groups (patient specific cutting blocks compared to conventional cutting blocks).
Difference in patient reported knee function between baseline and one year and also between study groups.1 yearValidated patient reported knee function questionnaires as measured by EQ-5D pre-operation and at one year post-operation. Difference between baseline and one year scores for each patient and also analysed between groups (patient specific cutting blocks compared to conventional cutting blocks).
Difference in patient reported quality of life questionnaires between baseline and one year and also between study groups.1 yearValidated quality of life questionnaires as measured by SF-12 score pre-operation and at one year post-operation. Difference between baseline and one year scores for each patient and also analysed between groups (patient specific cutting blocks compared to conventional cutting blocks).
Healthcare cost1 yearHealthcare cost measured in pounds sterling (GBP). Total cost of performing knee replacement using conventional cutting blocks compared to using bespoke cutting blocks and disposable instrumentation. The measurable contributors to the costs of healthcare include operating time (minutes), number of instrument trays requiring sterilisation (number of trays), length of hospital stay (days), patient transfusion requirement (number of units of packed cells required), cost of bespoke disposable instrumentation (GBP).

Countries

United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026