Skip to content

Intra-luminal Radiofrequency Ablation for Inoperable Malignant Biliary Stenosis

Intra-luminal Radiofrequency Ablation for Inoperable Malignant Biliary Stenosis

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02841800
Enrollment
5
Registered
2016-07-22
Start date
2016-06-30
Completion date
2019-05-10
Last updated
2019-08-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bile Duct Cancer, Liver Cancer, Pancreatic Cancer

Keywords

radiofrequency ablation, malignant biliary stenosis

Brief summary

Only a small proportion of patients with biliary obstruction caused by hepatopancreatobiliary malignancies are suitable for surgical resection. Therefore, most patients with malignant biliary obstruction will need palliation of their obstructive jaundice to relieve the symptoms and prevent life threatening complications such as biliary sepsis. The endoscopic or percutaneous/transhepatic routes, such as endoscopic retrograde cholangiopancreatography (ERCP) and percutaneous transhepatic cholangiography (PTC), and stents are accepted approaches for the relief of jaundice in malignant biliary obstruction. Improvement in the bilirubin level is also essential before palliative chemotherapy is considered in these patients. However, tumor ingrowth still remains a major cause of obstruction. In this trial, the investigators will use HabibTM EndoHPB (EMcision Ltd., UK) catheter which was used for the endobiliary radiofrequency ablation (RFA) treatment as a form of neoadjuvant therapy in hepatopancreatobiliary adenocarcinoma.

Detailed description

The HabibTM EndoHPB (EMcision Ltd., UK) catheter which was used for the endobiliary radiofrequency ablation (RFA) treatment is an endoscopic bipolar catheter designed to ablate tissue in malignant tumors within luminal structures. HabibTM EndoHPB has Food and Drug Administration (FDA) and European Conformity approval for such indications. It has also approved by Ministry of Health and Welfare in 2016. In this study, the investigators will perform intra-luminal RFA for 20 inoperable patients with malignant biliary stenosis. HabibTM EndoHPB will be deployed via an endoscopic retrograde cholangiopancreatography (ERCP) route. By using radiofrequency energy to heat the tissue in the duct prior to insertion of the stent, the surrounding tissue becomes coagulated and this may delay tumor growth and the time before the stent lumen becomes occluded. If stent occlusion occurs in a participant during the follow up period, the participant will be reassessed and investigations will be used to determine cause of stent occlusion and whether it is appropriate to repeat RFA treatment. The aim will be to detect an improvement in survival and safety in the treated patients compared to patient receiving palliative treatment recorded in literatures.

Interventions

DEVICE'Intra-luminal radiofrequency ablation (Habib EndoHPB)

endobiliary radiofrequency ablation device

Sponsors

National Taiwan University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* Patients must meet all of the following inclusion criteria to be eligible for this study: 1. 20 Years and older. 2. The diagnosis of hepatopancreaticobiliary cancers with pathologic proven, and the diagnosis of hepatopancreaticobiliary cancers will be made by pathology / cytology or according to the American Association for the Study of Liver Diseases (AASLD) (2010) diagnostic criteria. 3. Participant unsuitable for surgical resection. Criteria for unresectability being based on metastatic disease or locally advanced. 4. Eastern Cooperative Oncology Group (ECOG) score of 0-1. 5. American Society of Anaesthesiologists (ASA) score ≤ 3. 6. Karnofsky score \>30. 7. Jaundice (bilirubin level over 10 mg/dL). Alanine transaminase (ALT) and aspartate transaminase (AST) \< 5 x upper limit of normal. 8. Prothrombin time (PT)- international normalized ratio (INR) ≦ 2.0. Platelet count ≥ 100 K/Μl. 9. Expected to survive more than 3 months.

Exclusion criteria

* Patients presenting with any of the following will not be enrolled into this study: 1. Under the age of 20 years old. 2. Women who are pregnant or women of child-bearing potential who are not using an acceptable method of contraception. 3. Known history of human immunodeficiency virus (HIV) infection. 4. Patients who have any serious or systemic disease that is not a good fit for this test. 5. Tumor occupying more than 50% of liver parenchyma 6. Any active metal implanted device (eg Pacemaker). 7. Guidewire cannot pass through the bile duct stenosis.

Design outcomes

Primary

MeasureTime frameDescription
survival benefitup to 3 monthswhether survival benefit is conferred to patients in the study at 3 months

Secondary

MeasureTime frameDescription
the recurrence of bile duct obstruction and jaundiceup to 3 yearsTo analyze the recurrence of bile duct obstruction and jaundice.
potential treatment-related complicationsup to 3 yearsTo analyze potential treatment-related complications
repeated biliary interventionsup to 3 yearsTo analyze the number of repeated biliary interventions

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026