Skip to content

Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents for Diffuse Long Coronary Artery Disease

Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents for Diffuse Long Coronary Artery Disease

Status
Terminated
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02831205
Acronym
ABSORB-LONG
Enrollment
800
Registered
2016-07-13
Start date
2016-07-31
Completion date
2017-12-31
Last updated
2017-12-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Percutaneous Transluminal Coronary Angioplasty

Keywords

bioresorbable vascular scaffold, coronary artery disease

Brief summary

The purpose of this study is to determine whether ABSORB bioresorbable vascular scaffold is non-inferior to XIENCE everolimus-eluting cobalt-chromium stent with respect to target-lesion failure (TLF) at 1 year.

Interventions

DEVICEeverolimus-eluting bioresorbable vascular (Absorb) scaffold
DEVICEeverolimus-eluting cobalt-chromium (Xience) stent

Sponsors

CardioVascular Research Foundation, Korea
CollaboratorOTHER
Duk-Woo Park, MD
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age 18 and more * Diffuse long native coronary artery stenosis (\>50% by visual estimate) with lesion length of more than 40 mm requiring at least 2 overlapped stents with a reference-vessel diameter of 2.5 to 3.75 mm on visual assessment * Patients with silent ischemia, stable or unstable angina pectoris, and acute myocardial infarction including NSTEMI or STEMI * The patient or guardian agrees to the study protocol and the schedule of clinical follow-up, and provides informed, written consent, as approved by the appropriate Institutional Review Board/Ethical Committee of the respective clinical site

Exclusion criteria

* Subject has known hypersensitivity or contraindication to device material and its ingredients (everolimus, poly(L-lactide), poly(DL-lactide), lactide, lactic acid) and cobalt, chromium, nickel, platinum, tungsten, acrylic, and fluoro polymers that cannot be adequately premedicated * Subject has known allergic reaction, hypersensitivity, or contraindication to aspirin; to clopidogrel and prasugrel and ticagrelor; or to heparin and therefore cannot be adequately treated with study medication * An elective surgical procedure is planned that would necessitate interruption of antiplatelet drugs within 12 m after the procedure * STEMI requiring primary percutaneous coronary intervention * Cardiogenic shock * Restenotic lesions * Left main * Extreme angulation (≥90°) or excessive tortuosity (≥two 45° angles) proximal to or within the target lesion * Heavy calcification proximal to or within the target lesion * Compromised left ventricular dysfunction (LVEF \<30%) * At the time of screening, the subject has a malignancy that is not in remission * Terminal illness with life expectancy \<1 year * Patients who are actively participating in another drug or device investigational study, which have not completed the primary endpoint follow-up period * Patient's pregnant or breast-feeding or child-bearing potential

Design outcomes

Primary

MeasureTime frameDescription
Target lesion failure1 yearevent rate for composite of cardiac death, target-vessel myocardial infarction \[MI\], or ischemia-driven target-lesion revascularization

Secondary

MeasureTime frameDescription
Cardiac death5 years
Target-vessel myocardial infarction5 years
Ischemia-driven target-lesion revascularization5 years
event rate of any myocardial infarction; Q-wave vs Non-Q wave, periprocedural myocardial infarction vs follow-up myocardial infarction5 years
All-cause mortality5 years
Target-vessel failure5 yearsdeath from any cause, myocardial infarction, and ischemic-driven target-vessel revascularization
Stent thrombosis5 years
event rate of device success or procedural success5 yearsDevice success defined as angiographic evidence of \<30% final residual stenosis of the target lesion. Procedural success is defined as mean lesion diameter stenosis ≤50% and without the occurrence of in-hospital myocardial infarction (MI), target vessel revascularization (TVR), or death.
Patient-reported angina status measured by Seattle angina questionnaire5 years
Any revascularization5 yearsAny revascularization; target lesion vs. nontarget lesion, target vessel vs. nontarget vessel, ischemia-driven vs. not ischemia-driven

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026