Skip to content

Third Ventricle Echographic Study for Neuro-intensive Care Unit Patients

Third Ventricle Echographic Study for Neuro-intensive Care Unit Patients

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02830269
Acronym
ECHO-V3
Enrollment
100
Registered
2016-07-12
Start date
2016-08-18
Completion date
2017-05-16
Last updated
2018-12-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Brain Injuries, Neuro-intensive Care Unit Patients

Keywords

Neuro-ICU, Third ventricle, Computer Tomography, Transcranial Doppler ultrasonography

Brief summary

Transcranial Doppler ultrasonography is usually used in the evaluation and management of patients with brain injury. This noninvasive method measures local blood flow velocity and direction in the proximal portions of large intracranial arteries. The operator requires a short training and experience to perform. The third ventricle diameter measurement by transcranial duplex flow sonography was performed in healthy volunteers . This studies show similar results in those obtained with the MRI or Computer Tomography (CT). Currently the third ventricle diameter measurements by transcranial Doppler ultrasonography was not validated for neuro-intensive care unit patients. The investigators propose to used recent ultrasound system to validate the third ventricle diameter measurements in comparison with the standard method (CT).

Detailed description

Transcranial Doppler ultrasonography is usually used in the evaluation and management of patients with brain injury. This noninvasive method measures local blood flow velocity and direction in the proximal portions of large intracranial arteries. The operator requires a short training and experience to perform. The third ventricle diameter measurement by transcranial duplex flow sonography was performed in healthy volunteers . This studies show similar results in those obtained with the MRI or Computer Tomography (CT). Currently the third ventricle diameter measurements by transcranial Doppler

Interventions

DEVICETranscranial Doppler ultrasonography measurements

Third ventricle diameter measurements with standard method (CT) and Transcranial Doppler ultrasonography

Sponsors

University Hospital, Montpellier
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

* Adult, \> or equal to 18-yr * Admission to neuro-intensive care unit with brain injury * Evaluation by Computer Tomography * Indication for Transcranial Doppler ultrasonography

Exclusion criteria

* Opposition to participate by the patient or a next of kin

Design outcomes

Primary

MeasureTime frameDescription
Third ventricle diameter (average +/- standard deviation)Through study completion (30 months)Spearman's test measuring the correlation coefficient between the third ventricle diameter measured by the expert using the ultrasonography and the third ventricle diameter measured by CT scan.

Secondary

MeasureTime frameDescription
Residents' learning curve24 monthsThe learning curve will be determined by the change in the third ventricle diameter's difference obtained by the expert and the resident, divided by the diameter obtained by the expert reported on the Y-axis and the number of measures done by the resident reported on the X-axis. Number of measures to be done will be determined when the curve reached the zero.

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 15, 2026