Skip to content

Assessment Of MRI In Patients With Implanted Cardiac Devices

Assessment Of MRI In Patients With Implanted Cardiac Devices

Status
Withdrawn
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02815384
Acronym
MRIPACER
Enrollment
0
Registered
2016-06-28
Start date
2017-10-12
Completion date
2019-04-16
Last updated
2024-09-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Arrhythmias, Cardiac

Brief summary

The research goal is to continue to add to the extensive body of peer-reviewed evidence that demonstrates MRI may be safely performed in patients with cIEDs, after they have been evaluated and cleared by cardiology. This study will allow the researchers to collect data from the facilities ongoing clinical practice regarding the number and types of any adverse clinical reactions, and also to document any changes in the implanted cardiac device that may have occurred during the MRI scan. The researchers will also be assessing the results of the MRI and how the imaging findings impact patient care and the clinical outcome of the patient. This data will then be presented to the FDA and the Centers for Medicare and Medicaid Services to further influence federal guidelines and payment structures.

Detailed description

Cardiac implantable electronic devices (cIEDs) generally refer to implanted pacemakers and defibrillators for patients with cardiac disorders affecting their heart rhythm. Previously, cIEDs have been regarded as a contraindication to magnetic resonance imaging (MRI) scans, with concerns that the magnetic fields of the MRI may cause problems with the patient's cIED. However, this is a major healthcare issue, as approximately 50-75% of patients with implanted cIEDs are expected to need a future MRI as part of their clinical care. The inability to get such a test may negatively impact the ability to diagnose and treat future diseases. However, many of the initial concerns regarding the capability of performing MRI in patients with cIED have likely been overstated. There is peer-reviewed literature dating back to the 1990s regarding the ability to safely perform MRI in patients with cIEDs, if certain protocols are followed regarding patient selection and monitoring. In 2011, Nazarian et al from Johns Hopkins University published a study on 438 patients with cIED that received MRI. There were no adverse clinical effects from this study. In fact, the American College of Radiology updated it's guidance document for Safe MR Practices, and cIEDs are no longer listed as a relative contraindication to obtaining an MRI. However, the presence of cIEDs are still regarded as a relative contraindication to performing MRI at some centers. In addition, performance of MRI in the setting of cIED is denied by the Centers for Medicare and Medicaid Services. Continued accrual of data regarding the safety of performing MRI in patients with cIEDs is needed, including outcomes studies that document the clinical impact of improved diagnostics provided by the MRI on patient care.

Interventions

None listed

Sponsors

University of Arizona
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* All patients that require an MRI as part of the normal course of their medical care that also have a cIED and are candidates for MRI .

Exclusion criteria

* patient does not require an MRI for their medical care * patient does not have a cIED * patient has not been seen or approved by cardiology to be a candidate for MRI * patients under the age of 18 * pregnant patients * prisoners

Design outcomes

Primary

MeasureTime frameDescription
Safety of MRI, adverse clinical eventsimmediately post MRIcollect safety data

Secondary

MeasureTime frameDescription
Impact to Patient Care6 monthsassess the results of the MRI and how the imaging findings impact patient care
Morbidity, Number of hospitalizations6 monthscollected from medical record