Skip to content

Dynamic Stress Perfusion CT for Detection of Inducible Myocardial Ischemia

Dynamic Stress Perfusion ct for Detection of Inducible Myocardial Ischemia

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02810795
Acronym
SPECIFIC
Enrollment
180
Registered
2016-06-23
Start date
2016-06-07
Completion date
2020-12-10
Last updated
2020-12-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Keywords

Coronary, Artery, Computed tomography, FFR, CT myocardial perfusion, Dynamic

Brief summary

The purpose of this study is to determine the diagnostic accuracy of MPICT for the detection of hemodynamically relevant coronary stenosis (as determined by invasive FFR) in patients with suspected or known CAD clinically referred for invasive angiography.

Detailed description

Rationale: Cardiac computed tomography (CT) provides accurate assessment of the coronary arteries and detects significant coronary stenosis with high diagnostic accuracy. However, the hemodynamic relevance of these stenotic lesion remains unclear, although highly relevant for clinical decision-making. Recent technical developments with third-generation dual-source CT allow to determine myocardial perfusion during hyperemia and thus for assessment of the hemodynamic relevance of coronary lesions using a dynamic acquisition mode. To date, there is only very limited evidence of the feasibility of this approach stemming from single-center studies with varying standards of reference. Objective: To determine the diagnostic accuracy of MPICT for the detection of hemodynamically relevant coronary stenosis (as determined by invasive FFR) in patients with suspected or known CAD clinically referred for invasive angiography. In an optional sub-study the diagnostic accuracy of MPICT for the detection of myocardial perfusion defects as determined by cardiac magnetic resonance imaging (CMRI) will be investigated. Study design: Observational cohort study with fractional flow reserve (FFR) during invasive angiography as the reference standard. Study population: Patients with known or suspected CAD clinically referred for invasive angiography. Main study parameters: Myocardial perfusion defect on dynamic CT perfusion imaging, and diagnostic accuracy as compared invasive FFR. Co Principle Investigators Koen Nieman MD PhD, Erasmus University Medical Center Fabian Bamberg MD PhD, University of Tübingen. Investigators Valerie Schmidt-Honndorf PhD, University of Tübingen Tobias Geisler MD PhD, University of Tübingen Joost Daemen MD PhD, Erasmus University Medical Center Adriaan Coenen MD, Erasmus University Medical Center Stephan Achenbach MD PhD, Erlangen University Micheala M. Hell MD, Erlangen University Rozemarijn Vliegenthart MD PhD, UMC Groningen Pim van der Harst MD PhD, UMC Groningen Francesca Pugliese MD PhD, Queen Mary University of London Kakuya Kitagawa MD PhD, Mie University Hatem Alkadhi MD PhD, University Hospital Zurich, Switzerland Robert Manka MD PhD, University Hospital Zurich, Switzerland

Interventions

OTHERDiagnostic detection of coronary artery disease

Myocardial perfusion defect on dynamic CT perfusion imaging, and diagnostic accuracy as compared invasive FFR.

Sponsors

University Hospital Tuebingen
CollaboratorOTHER
Siemens Medical Solutions
CollaboratorINDUSTRY
Bayer
CollaboratorINDUSTRY
University of Erlangen-Nürnberg
CollaboratorOTHER
University Medical Center Groningen
CollaboratorOTHER
Mie University
CollaboratorOTHER
University Hospital, Zürich
CollaboratorOTHER
Queen Mary University of London
CollaboratorOTHER
University Hospital Munich
CollaboratorOTHER
Erasmus Medical Center
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
21 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* Age 21-75 years * Stable angina symptoms, suspected or known CAD, and referred for invasive angiography on clinical grounds. * Ability to provide informed consent * Ability to perform a 20-30 second breath hold

Exclusion criteria

* Hemodynamically and clinically unstable condition (angina at rest, malignant arrhythmias) * Prior, documented myocardial infarction, other than (procedure related) minor type II myocardial infarction, which includes Q waves on the ECG or evidence of myocardial infarction on prior non-invasive imaging. * Prior stenting or coronary artery bypass graft surgery * Significant other cardiovascular conditions affecting the interpretation of MPICT, including, but not limited to: clinical heart failure, IECD (pacemaker/ICD), severe valvular heart disease or prosthetic valves, significant intra-cardiac shunting or other relevant congenital heart disease. * eGFR\<60 ml/kg/min * BMI\>30 kg/m2, or weight \>120 kg. * Atrial fibrillation or other arrhythmia, \>6 ectopic beats / min * Known or suspected allergy to iodinated contrast medium * Pregnancy cannot be excluded * Contra-indications for adenosine: bronchial asthma, second or third degree atrioventricular block, blood pressure \<110/70 mmHg, allergies or severe side effects in the past.

Design outcomes

Primary

MeasureTime frameDescription
Myocardial perfusionFor each patient within 4 weeks of the CT perfusion acquisitioninvasive fractional flow reserve measurement

Secondary

MeasureTime frame
Presence of myocardial perfusion defect on MPIMRIFor each patient within 1 week before invasive fractional flow reserve measurement
Per patient assessment of hemodynamically significant CADFor each patient within 4 weeks of the CT perfusion acquisition
Ischemia per standardized myocardial segmentFor each patient within 4 weeks of the CT perfusion acquisition
Demographics.For each patient within 1 week before invasive fractional flow reserve measurement
Coronary stenosis by invasive angiography per territory (branch)For each patient within 4 weeks of the CT perfusion acquisition
Cardiovascular risk factorsFor each patient within 1 week before invasive fractional flow reserve measurement
'Image quality, based on the DICOM images measured by experienced readers.Through study completion, an average of 1 to 2 years
Coronary stenosis by CTA per territory (branch)For each patient within 4 weeks of the CT perfusion acquisition

Countries

Netherlands

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 21, 2026