Skip to content

The Development and Clinical Verification of Intelligent Rehabilitation System for Leg Length Discrepancy Patients

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02793973
Enrollment
60
Registered
2016-06-08
Start date
2016-05-31
Completion date
Unknown
Last updated
2016-06-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Leg Length Discrepancy, Shoe Lifts

Brief summary

A structural leg length discrepancy (SLLD) is a common clinical problem. Its prevalence has been estimated at 40-70%. Those who have been suffered from limping for a long time may lead to follow-up low back pain and lower limb musculoskeletal disorders. Although lower limb triple view of x-ray is considered to be the current technique for determining LLD, it is costly and time consuming that not every hospital can afford it, and in case of radiograph, the patient is exposed to radiation. Therefore, it is necessary to develop a rapid clinical assessment method by gathering exterior parameters to build up a Regression model for measuring the discrepancy and determining LLD accurately. While using shoe lifts to correct discrepancy is the easiest conservative intervention for LLD, there are still many controversies on how much height should be added clinically and academically. The optimal height should be added depends on feedbacks from users and gait performance. The best gait performance can be measured from kinematic performance of center mass of body during walking. Therefore, this project wants to compare treatment responses between two kinds of shoe lift height correction methods for LLD: given 80% discrepancy in shoe lift height correction through triple view of x-ray and given optimal shoe lift height correction through analyzing kinematic performance of center mass of body.

Interventions

DEVICEshoe lifts

Sponsors

Taipei Veterans General Hospital, Taiwan
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
20 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

* aged 20 to 70 * being able to walk independently * being diagnosed with congenital SLLD or not * willing to cooperate to wear shoe lifts * has smart phone and willing to record information that investigators need * willing to sign agreement

Exclusion criteria

* neurological diseases (i.e. Parkinson's disease, CVA, Polio, and lower limb nerve injuries, etc.) * diabetes along with peripheral neuropathy * history of lower limb fracture injury or joint replacement leading to uneven leg length * osteoporosis along with compression fracture * foot, ankle, or knee joint deformity, osteoarthritis or soft tissue pain that disturb gait performance (ex. degenerative osteoarthritis, plantar fasciitis, and etc.) * pregnancy * idiopathic scoliosis * history of psychological disease or drug addiction

Design outcomes

Primary

MeasureTime frameDescription
Visual analogue scale, VASChanges from baseline in VAS for six month continuallyPain fields of every participant in two groups will be recorded by APP every day for six month continually. The pain fields include:bilateral cervical, trunk, upper limb, lower limb, and foot regions, totally 10 regions. The score of each region is determined by measuring the distance (mm) on the 10-cm line between the no pain anchor and the patient's mark, providing a range of scores from 0-100. A higher score indicates greater pain intensity. The total score may range from 0-1000.

Secondary

MeasureTime frameDescription
areas of pain (cm^2)Changes from baseline in areas of pain one time per week for six monthAreas of pain in two groups will be calculated and recorded by APP. The pain fields include:bilateral cervical, trunk, upper limb, lower limb, and foot regions, totally 10 regions. The APP will give participants figures of every region. Each region will be filled with grids. Participants need to select specific grids, according to how many areas pain covers.
spatio-temporal parameters of gaitChanges from baseline in spatio-temporal parameters of gait after intervention immediately and at 4, 8, 12, 24 weeksGAITRite Walkway, CIR Systems, Havertown, PA, USA. The GaitRITE system was developed in response to the need for an objective way to quantify gait and ambulatory status. The GAITRite System measures spatio-temporal parameters of gait such as cadence, step length, step width, velocity, and toe-out angle, providing clinically relevant information that is useful in devising treatment plans and evaluating treatment outcomes. The system tracks parameters over time and can be used to generate progress and status reports.
three dimensional changing joint angles and trunk sway during walkingChanges from baseline in three dimensional joint angles between two segments and trunk sway during walking after intervention immediately and at 4, 8, 12, 24 weekmyoMOTION, Noraxon USA Inc., Scottsdale, AZ, USA. Wireless and portable 3D Kinematic System reveals what's unnoticeable to the naked eye, from small angular displacements to major movement pattern compensations. It contains 13 sensors fixed at bilateral dorsal side of foot, anterior medial side of tibia, lower quadrant of quadriceps, T12/L1, C7, lateral and longitudinal side of upper arm below the trapezius muscle belly, distal part of forearm and sacrum for measuring three dimensional joint angles between two segments and trunk sway during walking.
muscle activityChanges from baseline in muscle activity after intervention immediately and at 4, 8, 12, 24 weeksFree EMG 300, BTS Bioengineering, Milan, Italy. BTS FREEEMG 300A is a wireless synchromyography device for dynamic muscular activity analysis. It contains eight channels for detecting muscle activity, including bilateral gluteus medius, vastus lateralis, plantar flexor, and anterior tibialis.
Degree of comfortChanges from baseline in comfort scale for six month continuallyDegree of comfort at foot site in two groups will be recorded by APP every day for six month continually. The score ranges from 0-10. A higher score indicates greater comfort.
plantar pressure (kgw/cm^2)Changes from baseline in plantar force and pressure after intervention immediately and at 4, 8, 12, 24 weekswireless F-Scan, Tekscan Inc., Boston, MA, USA. The F-Scan system provides dynamic pressure, force and timing information for foot function and gait analysis. Its pressure sensing film will be put between feet and shoe lifts to measure heel, medial forefoot, metatarsal head and hallux plantar pressure.The more even value of both sides indicates the better correction.
contact area (cm^2)Changes from baseline in plantar force and pressure after intervention immediately and at 4, 8, 12, 24 weekswireless F-Scan, Tekscan Inc., Boston, MA, USA. The F-Scan system provides dynamic pressure, force and timing information for foot function and gait analysis. Its pressure sensing film will be put between feet and shoe lifts to measure contact area of region of interest. The value will be further calculated for determining whether the foot pronation/supination has been corrected.
Energy expenditure (Joule)Changes from baseline in plantar force and pressure after intervention immediately and at 4, 8, 12, 24 weeksiPod Touch, Apple Inc., Cupertino, CA, USA. It will be fixed at lumbar-sacrum junction to measure three-dimensional instantaneous linear acceleration of center mass of body, and further to analyze kinematic performance by calculating three dimensional thrust power and thrust energy. The less energy expends, the better kinematic performance of center mass of body displays.
plantar force (kgw)Changes from baseline in plantar force and pressure after intervention immediately and at 4, 8, 12, 24 weekswireless F-Scan, Tekscan Inc., Boston, MA, USA. The F-Scan system provides dynamic pressure, force and timing information for foot function and gait analysis. Its pressure sensing film will be put between feet and shoe lifts to measureheel, medial forefoot, metatarsal head and hallux plantar force. The more even value of both sides indicates the better correction.

Contacts

Primary ContactChen Hsin Lu
corniculatastar@gmail.com886+2+28712121

Outcome results

None listed