Skip to content

Ventilation Using a Bag Valve Mask With Integrated Internal Handle

Single Rescuer Ventilation Using a Bag Valve Mask With Integrated Internal Handle Versus Standard Bag Valve Mask in a Manikin Model: A Randomized Crossover Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02792049
Enrollment
70
Registered
2016-06-07
Start date
2015-07-31
Completion date
2015-10-31
Last updated
2016-10-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Apnea

Brief summary

Investigators compared tidal volumes for single rescuer ventilation using a modified bag valve mask with an integrated internal handle versus a conventional bag valve mask in a manikin model.

Detailed description

This was a prospective, randomized, crossover study to assess the tidal volume delivered using a standard and modified bag valve mask (BVM) device in a manikin airway model. Data was collected from July 2015 through October 2015 at the San Antonio Military Medical Center. Emergency medicine providers (physicians, physician assistants, residents, nurses, medics) were randomized to device order. Prior to participation each participant filled out a survey indicating their job status, gender, years of medical experience, and experience level with BVM ventilation. Hand grip strength and size (length, width, span) were measured. Each participant was then asked to provide BVM ventilation using the assigned devices at a rate of 10 breaths per minute for 3 minutes for a total of 30 breaths. Tidal volume of each delivered breath was recorded in milliliters. After a 3 minute rest period, testing was repeated with the second device. After ventilation with each device, participants completed an anonymous questionnaire that used a Likert scale to assess perceived qualities of the modified device including ease of use, ability to provide a superior mask seal, willingness to use in an emergency situation, and overall preference between the two devices. Each participant served as his/her own control.

Interventions

Subjects deliver breaths to manikin (IngMar RespiTrainer manikin model) a modified Ambu Spur II bag valve mask with integrated internal handle

Subjects deliver breaths to manikin (IngMar RespiTrainer manikin model) a conventional Ambu Spur II bag valve mask

Sponsors

Brooke Army Medical Center
Lead SponsorFED

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Emergency Department healthy volunteers (physician assistants, residents, paramedics, nurses, medics, respiratory therapists.

Exclusion criteria

* Not trained in basic life support

Design outcomes

Primary

MeasureTime frameDescription
Mean Received Tidal Volume3 minutesEach participant was asked to provide BVM ventilation using the assigned devices at a rate of 10 breaths per minute for 3 minutes for a total of 30 breaths. Tidal volume of each delivered breath was recorded in milliliters

Secondary

MeasureTime frameDescription
Modified Bag Valve Mask (BVM) Ease of UseWithin 10 minutes of study completionLikert scale measuring subject's perceived ease of use of the modified BVM device from not at all easy to use (1) to very easy to use (5).
Modified Bag Valve Mask (BVM) Better Seal FormationWithin 10 minutes of study completionSubjects response using a Likert scale (1-5) regarding their perceptions of whether the modified BVM forms a better seal compared to a standard BVM: 1 (much worse seal formation) to 5 (much better seal formation).
Modified Bag Valve Mask (BVM) Willingness to Use in Emergency SituationWithin 10 minutes of study completionSubject reported willingness to use the modified BVM in a real life emergency situation as measured on a Likert scale ranging 1 (not at all willing to use) to 5 (very willing to use).
Number of Participants Who Preferred the Modified Bag Valve Mask (BVM)Within 10 minutes of study completionEach subject provides a binary response as to whether he/she overall prefers using the modified BVM instead of the conventional BVM.

Countries

United States

Participant flow

Participants by arm

ArmCount
Modified Ambu Bag Valve Mask (BVM) First Then Unmodified BVM
A healthcare provider volunteer uses a modified Ambu Spur II bag valve mask with integrated internal handle (experimental device, not yet FDA approved) to deliver 10 breaths per minute for 3 minutes to a manikin (IngMar RespiTrainer manikin model). The subject then repeats these procedures using an unmodified Ambu bag valve mask.
35
Unmodified Ambu Bag Valve Mask (BVM) First Then Modified BVM
A healthcare provider volunteer uses a conventional Ambu Spur II bag valve mask to deliver 10 breaths per minute for 3 minutes to a manikin (IngMar RespiTrainer manikin model). The subject then repeats these procedures using a modified Ambu Spur II bag valve mask with integrated handle.
35
Total70

Baseline characteristics

CharacteristicModified Ambu Bag Valve Mask (BVM) First Then Unmodified BVMUnmodified Ambu Bag Valve Mask (BVM) First Then Modified BVMTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
0 Participants0 Participants0 Participants
Age, Categorical
Between 18 and 65 years
35 Participants35 Participants70 Participants
Region of Enrollment
United States
35 participants35 participants70 participants
Sex: Female, Male
Female
9 Participants11 Participants20 Participants
Sex: Female, Male
Male
26 Participants24 Participants50 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
0 / 350 / 35
serious
Total, serious adverse events
0 / 350 / 35

Outcome results

Primary

Mean Received Tidal Volume

Each participant was asked to provide BVM ventilation using the assigned devices at a rate of 10 breaths per minute for 3 minutes for a total of 30 breaths. Tidal volume of each delivered breath was recorded in milliliters

Time frame: 3 minutes

ArmMeasureValue (MEAN)Dispersion
Modified Ambu Spur II Bag Valve MaskMean Received Tidal Volume681 millilitersStandard Deviation 148
Conventional Ambu Spur II Bag Valve MaskMean Received Tidal Volume591 millilitersStandard Deviation 142
Secondary

Modified Bag Valve Mask (BVM) Better Seal Formation

Subjects response using a Likert scale (1-5) regarding their perceptions of whether the modified BVM forms a better seal compared to a standard BVM: 1 (much worse seal formation) to 5 (much better seal formation).

Time frame: Within 10 minutes of study completion

ArmMeasureValue (MEDIAN)
Modified Ambu Spur II Bag Valve MaskModified Bag Valve Mask (BVM) Better Seal Formation4 Units on a scale
Conventional Ambu Spur II Bag Valve MaskModified Bag Valve Mask (BVM) Better Seal Formation4 Units on a scale
Secondary

Modified Bag Valve Mask (BVM) Ease of Use

Likert scale measuring subject's perceived ease of use of the modified BVM device from not at all easy to use (1) to very easy to use (5).

Time frame: Within 10 minutes of study completion

ArmMeasureValue (MEDIAN)
Modified Ambu Spur II Bag Valve MaskModified Bag Valve Mask (BVM) Ease of Use5 Units on a scale
Conventional Ambu Spur II Bag Valve MaskModified Bag Valve Mask (BVM) Ease of Use5 Units on a scale
Secondary

Modified Bag Valve Mask (BVM) Willingness to Use in Emergency Situation

Subject reported willingness to use the modified BVM in a real life emergency situation as measured on a Likert scale ranging 1 (not at all willing to use) to 5 (very willing to use).

Time frame: Within 10 minutes of study completion

ArmMeasureValue (MEDIAN)
Modified Ambu Spur II Bag Valve MaskModified Bag Valve Mask (BVM) Willingness to Use in Emergency Situation5 Units on a scale
Conventional Ambu Spur II Bag Valve MaskModified Bag Valve Mask (BVM) Willingness to Use in Emergency Situation5 Units on a scale
Secondary

Number of Participants Who Preferred the Modified Bag Valve Mask (BVM)

Each subject provides a binary response as to whether he/she overall prefers using the modified BVM instead of the conventional BVM.

Time frame: Within 10 minutes of study completion

ArmMeasureValue (NUMBER)
Modified Ambu Spur II Bag Valve MaskNumber of Participants Who Preferred the Modified Bag Valve Mask (BVM)28 participants
Conventional Ambu Spur II Bag Valve MaskNumber of Participants Who Preferred the Modified Bag Valve Mask (BVM)28 participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026