Skip to content

Safety and Feasibility of Polychromatic Light Emitting Diode for Peripheral Catheter Illumination During Peripheral Intravenous Delivery of Normal Saline

A Polychromatic Light Emitting Diode System to Deliver Low Dose Light Directly Into a Peripheral Intravascular Catheter: A Safety and Feasibility Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02785133
Enrollment
3063
Registered
2016-05-27
Start date
2014-12-31
Completion date
2016-10-31
Last updated
2016-10-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Quality of Life, Fatigue

Brief summary

This study uses a prospective non-randomized, non-controlled design. Five-hundred (500) subjects having previously received a peripheral intravenous therapy will be enrolled into a single treatment group. The purpose of the study is to evaluate the safety, feasibility, and improved energy levels following treatment with a low-light source integrated into an existing peripheral intravascular catheter. The absence of a control group is based on the following reason:This is a pilot investigation to establish a baseline understanding of the safety, feasibility, and cursory utility of polychromatic light emitting diodes integrated into an existing 20-gauge 1.0 inch intravenous catheter to improve self-reported overall subject energy levels.

Detailed description

This study uses a prospective non-randomized, non-controlled design. Five-hundred (500) subjects having previously received a peripheral intravenous therapy will be enrolled into a single treatment group. The purpose of the study is to evaluate the safety, feasibility, and cursory utility of a low-light source integrated into an existing peripheral intravenous catheter. The absence of a control group is based on the following reason: This is a pilot investigation to establish a baseline understanding of the safety, feasibility, and cursory utility of polychromatic light emitting diodes integrated into an existing 20-gauge 1.0 inch peripheral intravascular catheter to improve self-reported overall subject energy levels based on the change in Epworth Sleepiness scores. Peripheral intravascular therapy has been used for decades as an effective therapy to maintain proper hydration and electrolyte levels, and has been deemed a non-significant medical procedure. Peripheral intravascular therapy can be infused with various molecular agents such as supplements (Vitamin B12) for the purpose of improving energy levels and overall quality of life. However, the use of normal saline as a standard alone helps improve hydration and cell function. Low-energy light therapy has been established as an alternative treatment for a myriad of medical conditions. Light-based therapy stimulates photoreceptors found within cells and can improve overall cellular bioenergetics. The concurrent administration of low-light therapy and peripheral intravascular normal saline therapy may serve as a viable therapy for the treatment for improvement in subject quality of life and energy levels Accordingly, this study is designed to assess the safety, feasibility, and cursory improvement in self-reported energy levels following intervention of low-light therapy integrated into a standard peripheral intravascular catheter.

Interventions

Non-coherent light source administered 365 nm, 630 nm, and 530 nm at an output intensity of 0.1 mW directly into an existing intravascular 20 gauge 1.0 catheter

DRUGNormal Saline Solution

150 ml of 0.9% Sodium Chloride Solution

20-gauge 1.0 catheter

Sponsors

UVLrx Therapeutics
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

* Voluntarily signed informed consent form * Ages 18-70 * Completed urine pregnancy examination with negative result * Self-reported energy level of \>4 on the Epworth sleepiness test * No breastfeeding for 3 months prior to enrollment

Exclusion criteria

* Active infection along potential intravenous catheter sites * Pacemaker * Currently taking prescription blood thinning medications (i.e. Warfarin) * Suffering from a chronic, progressive blood disorder, such as blood cancer (Thalassemia, Lymphoma, Myeloma, etc.) * Use of anti-inflammatory medications on a chronic basis (i.e. ibuprofen, aspirin, and steroids) * Suffering from blood clotting disorders (hypercoagulable condition, thrombocytosis, etc.) * Clinically significant anxiety and/or depression * Participated in a clinical study in the last 30 days * Clinical Cardiac Disease * Active Infection

Design outcomes

Primary

MeasureTime frameDescription
The use of polychromatic light therapy delivered through an intravascular catheter for the improvement in self-reported subject energy levelsBaseline and 10 weeksThe ESS is a self-administered questionnaire with 8 questions. It provides a measure of a person's general level of daytime sleepiness, or their average sleep propensity in daily life. It has become the world standard method for making this assessment. The Epworth Sleepiness Scale will be used to evaluate subject energy levels at both baseline and post-procedure administration phase. Subjects will rate, on a 4-point scale (0 - 3), their usual chances of dozing off or falling asleep in 8 different situations or activities that most people engage in as part of their daily lives, although not necessarily every day. It evaluates what the chances are that they would doze off whenever they were in each situation.

Secondary

MeasureTime frameDescription
Subject satisfaction based on five (5)-point satisfaction questionnaire10 weeksSelf-reported overall treatment satisfaction based on perceived response from treatment
The improvement in subject quality of life using a five (5)-point GRA10 weeksDescriptive scale evaluating subject's perceived quality of life following treatment administration scale

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026