Skip to content

Comparison of SUV Using SPECT/CT Between Grave's Disease Patients and Normal Humans

Comparison of Standardized Update Value Using Single-photo Emission Computed Tomography and Computed Tomography Between Grave's Disease (Hyperthyroidism) Patients and Normal Humans

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02772705
Enrollment
100
Registered
2016-05-13
Start date
2016-05-31
Completion date
2017-01-31
Last updated
2016-05-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Emission-Computed, Hyperthyroidism, Single-Photon, Tomography

Keywords

Standardized Uptake Value, Diagnosis

Brief summary

The purpose of this study is to find out the capacity of standardized uptake value (SUV) using single-photo emission computed tomography and computed tomography (SPECT/CT) in diagnosing Grave's Disease (hyperthyroidism).

Detailed description

Traditionally it is considered that only positron emission tomography(PET) has the ability to obtain standardized uptake value(SUV)while single-photo emission computed tomography(SPECT) does not have. Recently with the developing of technology, the ability of SPECT has been extended. On the other hand, thyroid imaging by SPECT can only play an auxiliary role in hyperthyroidism diagnosis mainly since it is regarded as nonquantitative. So the investigators design this study to search the capacity and accuracy of SUV provided by SPECT and CT(CT is used for reconstruction algorithm) in diagnosing GD. This is a multiple-center study containing nine groups in China that use GE Discovery NM/CT, an advanced equipment. Thus, the data can be more accurate and more available. And this is a perspective clinical trial, taking about eight months. The investigators plan to evaluate at least 50 Grave's Disease(GD) patients and 50 normal humans as contrast in all. Every GD patient must have been diagnosed and the results of thyroid function tests(such as TSH,FT3,FT4) must be available. If necessary, the patient's rate of iodine uptake should also be known before he/she being included in this study. As for normal people, the results of thyroid function tests should be within the range of normal value. The data of each participant will be gathered and stored. And the data processing will be done with the help of GE staff, using the software Q.Metrix to get the value of SUVmean, SUVmax. Finally T test will be used in comparison of the differences.

Interventions

None listed

Sponsors

Beijing Tongren Hospital
CollaboratorOTHER
Guangzhou Panyu Central Hospital
CollaboratorOTHER
Hebei General Hospital
CollaboratorOTHER
Air Force Military Medical University, China
CollaboratorOTHER
Zhejiang Cancer Hospital
CollaboratorOTHER
The First Affiliated Hospital of Zhengzhou University
CollaboratorOTHER
Tianjin Medical University General Hospital
CollaboratorOTHER
West China Hospital
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

For Group of GD Patients: Inclusion Criteria: * certainly diagnosed with GD * no treatment * sign a informed consent

Exclusion criteria

* Inflammatory Hyperthyroidism * Secondary Hyperthyroidism (since of medicine, thyrotrophs neoplasms and etc) * Can not finish the check of SPECT/CT * Refuse to sign a informed consent For Group of Normal Humans: Inclusion Criteria: * without GD * Adult * sign a reformed consent

Design outcomes

Primary

MeasureTime frameDescription
The thyroid imaging of GD patients and normal humans by SPECT/CTa single point in time, at subject enrollmentFor GD patients and normal healthy volunteers, we will get the data of thyroid fusion imaging by giving them a SPECT/CT check at subject enrollment.
The SUV values of GD patients and normal humans provided by Q.Metrixa single point in time, at subject enrollmentThe data of thyroid fusion imaging will be processed by the software, Q.Metrix, which can get the accurate SUV by compensating for photon absorption within the body, removing scattered radiation and etc.

Countries

China

Contacts

Primary ContactYahao Li, Bachelor
617381606@qq.com+86 18080141841
Backup ContactLin Li, Master
lilinhuaxi@sina.com+86 13881833145

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026