Skip to content

Caisson Transcatheter Mitral Valve Replacement (TMVR) System Early Feasibility Study

Percutaneous Mitral Valve Replacement EvaLuation Utilizing IDE Early Feasibility Study (PRELUDE)

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02768402
Acronym
PRELUDE
Enrollment
20
Registered
2016-05-11
Start date
2016-06-30
Completion date
2023-12-31
Last updated
2020-01-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mitral Valve Regurgitation

Keywords

Mitral Valve Regurgitation, Primary MR, Secondary MR, MR, Heart Failure, Structural Heart, Secondary Mitral Valve Regurgitation, Primary Mitral Valve Regurgitation, Transseptal, Transcatheter

Brief summary

The purpose of this study is to assess the safety and performance of the Caisson Interventional Transcatheter MitralValve Replacement (TMVR) system for the treatment of severe symptomatic MitralValve Regurgitation (MR).

Detailed description

The treatment guidelines for valvular heart disease indicate that surgical correction of primary mitral valve regurgitation (MR) is a Class I recommendation. Further, recent evidence indicates that valve replacement is at least as effective as repair in both primary and secondary MR patients. However, many patients are not referred for surgery as they are considered to be too high of a risk to undergo on pump, open-heart procedures. Percutaneous aortic valve replacement has made treatment of stenosed aortic valves available to high-risk surgical patients who would have otherwise been medically managed. Percutaneous mitral valve (MV) replacement offers similar advantages. Currently, the only approved percutaneous treatment for MR is MitraClip. MitraClip is limited to a specific population of high risk surgical patients with valvular prolapses that are amenable to repair by the edge to edge technique. The feasibility of percutaneous MV replacement has been shown in animal studies, the implantation of aortic valves at the mitral position, and early evaluations of purpose made transcatheter MVs in humans. To meet this medical need, Caisson Interventional has developed a percutaneous delivery system for a bioprosthetic mitral valve. As with patients with aortic valve (AV) deficiencies, this device can be used to provide needed therapy to patients who might not otherwise receive treatment beyond medical therapy. This study will provide initial information on the safety and performance of this system.

Interventions

DEVICECaisson TMVR System

Transcatheter mitral valve replacement is a percutaneous procedure used to treat mitral valve regurgitation with a prosthetic valve implantation.

Sponsors

Caisson Interventional LLC
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Has severe mitral regurgitation * New York Heart Association (NYHA) Class II, III, IVa or heart failure * High risk for cardiovascular surgery

Exclusion criteria

* Excessive calcification or thickening of mitral valve annulus, severe mitral stenosis, fused commissures, valvular vegetation or mass * Left ventricular end diastolic dimension \> 7cm * Left ventricular outflow tract obstruction * Severe right ventricular dysfunction * Stroke within 90 days; transischemic attack or myocardial infarction within 30 days of the index procedure

Design outcomes

Primary

MeasureTime frameDescription
Number of patients without Major Adverse Events (MAEs)30 daysFreedom from major adverse events including death, stroke, myocardial infarction and surgical reintervention through 30 days

Secondary

MeasureTime frameDescription
Number of patients with successful delivery and implantation of the prosthetic valve (technical success)IntraoperativeSuccessful delivery and retrieval of the transcatheter mitral valve delivery system; deployment and correct positioning (via intraoperative imaging) in the appropriate anatomic location of prosthetic valve with no requirement for additional surgery
Number of living, stroke-free patients with prosthetic valve in place (device success)30 daysPatient is alive, stroke-free, original intended device in place (echo), no mitral valve surgical re-intervention required

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026