International Registry for ASD Closure by Using the Occlutech®Flex II Device in More Than 2000 Patients

International Registry for Secundum Atrial Septal Defects Closure by Using the Occlutech®Flex II Device in More Than 2000 Patients

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02766569
Acronym
IRFACODE-II
Enrollment
2000
Registered
2016-05-10
Start date
2016-07-31
Completion date
2017-12-31
Last updated
2016-09-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Septal Defect

Keywords

IRFACODE II, ASD closure, ASD device, erosion, arrhythmia

Brief summary

The IRFACODE II study will evaluate the performance and safety of the Occlutech® Flex II device in patients with closure of secundum atrial septal defects (ASD II).

Detailed description

Introduction: Interventional ASD closure is generally a safe procedure with only a small amount of severe side effects including mainly erosion of the atrial wall, embolizations and arrhythmias. The IRFACODE study has shown excellent results in Patients with various generations of the Occlutech devices. IRFACODE II study will evaluate the performance and safety of the Occlutech® Flex II device in patients with closure of secundum atrial septal defects (ASD II). Methods: The IRFACODE II study is a retrospective, non-randomized open access study for centres with a minimum of about 50 patients to evaluate the safety and side effects of ASD closure with this device. A minimum of 2000 patients that have an ASD II closed with this device until 31. June 2016 will be enrolled, the follow-up will be until 31. June 2017. Primary outcome measures for safety are the amount of erosions over a minimum follow-up time of 12 months. Primary outcome measures for device performance will include the success of complete ASD closure. Secondary outcome measures for safety will include the technique of implantation, the success rate in anatomically difficult ASDs, the incidence of arrhythmias (AV block, atrial fibrillation or flutter), device embolization, embolic events or migraine. A subgroup analysis according to patients age and anatomy of the defect will be performed. Outlook: The IRFACODE II study is the first trial intended to detect the actual incidence of erosion after ASD closure using the Flex II device. Although the trial is primarily designed to study the safety and device performance, the incidence of other potential side effects will be also evaluated.

Interventions

DEVICEASD closure with the Occlutech Flex II ASD closure device

Monitoring of possible device related side effects with a minumum of 1 year follow-up.

Sponsors

Ludwig-Maximilians - University of Munich
Lead SponsorOTHER

Study design

Observational model
COHORT

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

ASD for device closure \-

Exclusion criteria

* life expectancy \< 12 months * participating in another study

Design outcomes

Primary

MeasureTime frameDescription
number of erosionsminimum 1 yeardetection of erosions of the atrial wall after ASD closure

Secondary

MeasureTime frameDescription
number of arrhythmiasminimum 1 yeardetection of arrhythmias after ASD closure
successful implantationminimum 1 yearnumber of successful device implantations after device was placed inside the heart
embolizationminimum 1 yearnumber of events of device embolization during Implantation and follow-up