Pseudophakic Astigmatic Reduction With Verion-LenSx Arcuate Incisions

Pseudophakic Astigmatic Reduction With Verion-LenSx Arcuate Incisions

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02763124
Enrollment
18
Registered
2016-05-05
Start date
2016-05-31
Completion date
2016-10-31
Last updated
2019-11-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Astigmatism

Keywords

Pseudophakic

Brief summary

To assess the effectiveness of the Verion-LenSx guided arcuate incision technique to reduce astigmatism in a pseudophakic population.

Detailed description

The purpose of this study is to evaluate the effectiveness of corneal arcuate incisions when they are performed with a femtosecond laser system on subjects who have had previous cataract surgery. The procedure to be used would not be different from that employed during cataract surgery, except that the only corneal incisions made would be the partial-depth arcuate incisions at the laser.

Interventions

PROCEDUREVerion-LenSx

The Verion-LenSx femtosecond laser system will be used to create one or two partial-depth corneal arcuate incisions

Sponsors

Alcon, a Novartis Company
CollaboratorINDUSTRY
Gainesville Eye Associates
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
40 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Age 40 or older * Willing and able to provide informed consent for participation in the study.

Exclusion criteria

\-

Design outcomes

Primary

MeasureTime frameDescription
Uncorrected Monocular Distance Visual Acuity60 days (+/- 10 days) after laser treatmentUncorrected monocular distance visual acuity, measured on a logMAR scale, (logarithm of the Minimum Angle of Resolution) which is a measure of visual acuity in which the smaller values indicate better visual acuity.

Secondary

MeasureTime frameDescription
Change in Corneal Astigmatism60 days (+/- 10 days) after laser treatmentVector change in the astigmatism measured on the cornea, in diopters
Change in Refractive Cylinder60 days (+/- 10 days) after laser treatmentThe vector change in refractive cylinder in diopters
Spectacle Independence at Distance60 days (+/- 10 days) after laser treatmentPercentage of subjects that do not rely on spectacles for distance vision

Countries

United States

Participant flow

Participants by arm

ArmCount
Verion-LenSx
The Verion-LenSx femtosecond laser system will be used to perform one or two corneal arcuate incisions. Verion-LenSx: The Verion-LenSx femtosecond laser system will be used to create one or two partial-depth corneal arcuate incisions
18
Verion-LenSx
The Verion-LenSx femtosecond laser system will be used to perform one or two corneal arcuate incisions. Verion-LenSx: The Verion-LenSx femtosecond laser system will be used to create one or two partial-depth corneal arcuate incisions
28
Total46

Baseline characteristics

CharacteristicVerion-LenSx
Age, Continuous68.8 years
STANDARD_DEVIATION 6.1
Average keratometry (diopters)44.27 diopters
STANDARD_DEVIATION 1.41
Corneal astigmatism (diopters)1.42 diopters
STANDARD_DEVIATION 0.54
Refractive cylinder (diopters)1.35 diopters
STANDARD_DEVIATION 0.3
Region of Enrollment
United States
18 participants
Sex: Female, Male
Female
19 Eyes
Sex: Female, Male
Male
9 Eyes

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 18
other
Total, other adverse events
1 / 18
serious
Total, serious adverse events
0 / 18

Outcome results

Primary

Uncorrected Monocular Distance Visual Acuity

Uncorrected monocular distance visual acuity, measured on a logMAR scale, (logarithm of the Minimum Angle of Resolution) which is a measure of visual acuity in which the smaller values indicate better visual acuity.

Time frame: 60 days (+/- 10 days) after laser treatment

ArmMeasureValue (MEAN)Dispersion
Verion-LenSxUncorrected Monocular Distance Visual Acuity0.14 logMARStandard Deviation 0.11
Secondary

Change in Corneal Astigmatism

Vector change in the astigmatism measured on the cornea, in diopters

Time frame: 60 days (+/- 10 days) after laser treatment

ArmMeasureValue (MEAN)Dispersion
Verion-LenSxChange in Corneal Astigmatism1.2 dioptersStandard Deviation 0.74
Secondary

Change in Refractive Cylinder

The vector change in refractive cylinder in diopters

Time frame: 60 days (+/- 10 days) after laser treatment

ArmMeasureValue (MEAN)Dispersion
Verion-LenSxChange in Refractive Cylinder1.21 dioptersStandard Deviation 0.42
Secondary

Spectacle Independence at Distance

Percentage of subjects that do not rely on spectacles for distance vision

Time frame: 60 days (+/- 10 days) after laser treatment

Population: There were 28 eyes of 18 subjects treated in the study. Spectacle independence is evaluated by subject, not eye.

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Verion-LenSxSpectacle Independence at Distance12 Participants