Resynchronization for Ambulatory Heart Failure Trial - LV Endocardial

Resynchronization for Ambulatory Heart Failure Trial - LV Endocardial

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02757976
Acronym
RAFT-LVendo
Enrollment
8
Registered
2016-05-02
Start date
2018-03-08
Completion date
2019-06-20
Last updated
2020-09-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure, Left Ventricular Dysfunction

Brief summary

This trial will compare two strategies for patients with Heart Failure, Left Ventricular systolic dysfunction, and intermediate QRS durations. The control group is conventional CRT. The experimental group is LVendo CRT

Detailed description

Patients randomized to the Conventional CRT will receive a CRT device with or without ICD. Device implantation will be performed within 10 working days of randomization. Patients randomized to LV endocardial CRT will receive a CRT device with or without ICD, placed in the same time frame and will have RA and RV leads implanted as the conventional CRT group. The device will be implanted in a facility that has the capacity to perform trans-atrial septal puncture with ultrasound guidance. The LV lead will be placed using a trans-atrial septal approach using a specially designed puncture tools and LVendo delivery tool kits specifically designed for this study

Interventions

Patients randomized to the Conventional CRT will receive a CRT device with or without ICD. Device implantation will be performed within 10 working days of randomization. Conscious sedation or general anesthesia can be used for the implant procedure. The device will be implanted in a facility that has the capacity to perform coronary sinus venography at the time of implantation. The RA lead will be placed in the RA appendage or high RA. The RV lead should be placed at the RV apex or distal RV septum (R wave \> 7 mV, pacing threshold \< 1.5 V at a pulse-width of 0.5 ms). The LV lead should be positioned through the CS to an LV branch. The lead should be placed at one of the left ventricular venous branches, avoiding the LV apex and scar region identified by pre-implant imaging.

DEVICELV endocardial CRT

Patients randomized to LV endocardial CRT will receive a CRT device with or without ICD, placed in the same time frame, and will have RA and RV leads implanted as the conventional CRT group. The device will be implanted in a facility that has the capacity to perform trans-atrial septal puncture with ultrasound guidance (TEE or ICE) at the time of implantation. The LV lead will be placed using a trans-atrial septal approach, using a specially designed puncture tools and LVendo delivery tool kits specifically designed for this study. Special care will be taken to avoid the LV apex and transmural scar identified by pre-implant imaging.

Sponsors

Medtronic
CollaboratorINDUSTRY
London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

This trial will compare two management strategies for patients with Heart Failure, left ventricular systolic dysfunction, and intermediate prolonged QRS duration (120-149ms). The control group is conventional Cardiac Resynchronization Therapy (CRT). The experimental group is LV endocardial CRT.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients with NYHA Class II or III or ambulatory IV HF symptoms * Optimal HF Medical Therapy of at least 3 months (2009 ACCF/AHA, ESC 2012) * LVEF less than or equal to 35% * Sinus rhythm (can have paroxysmal atrial fibrillation) * QRS morphology is non-RBBB * QRS durations more than or equal to 120 ms, but less than 150 ms * Patients are able to receive chronic oral anticoagulation * Patients with pacemaker or ICD that meet the above criteria may be upgraded to CRT-D or CRT-P

Exclusion criteria

* Planned Atrial Fibrillation Ablation within 12 months * Patients with mitral or tricuspid prosthetic valve that precludes the placement of an LV lead transvenously or trans-septally * Patients with RBBB * Patients with LV thrombus * Patients with permanent atrial fibrillation * Patients with contraindications to oral anti-coagulation * In-hospital patients with acute cardiac or non-cardiac illness that requires intensive care * Acute coronary syndrome (including MI) \< 4 weeks * Coronary revascularization (CABG or PCI) \< 3 months * Uncorrected or uncorrectable primary valvular disease * Restrictive, hypertrophic or reversible form of cardiomyopathy * Severe primary pulmonary disease such as cor pulmonale * Expected to undergo cardiac transplantation within one year (status I) * Patients with a life expectancy of less than one year from non-cardiac cause. * Patients included in other clinical trials that will affect the objectives of this study * Those unable or unwilling to provide informed consent * Those with a history of noncompliance to medical therapy

Design outcomes

Primary

MeasureTime frameDescription
Assessment of LVESViBaseline to 6 months & 12 monthsLV reverse remodeling as measured by the difference of LVESVi on echocardiography (echo)

Secondary

MeasureTime frameDescription
NT-proBNP measurementBaseline to 6 months & 12 months
Ventricular arrhythmia burden determined by the device capture of arrhythmias and adjudication by a device review committee blinded to patient's treatment allocation.Baseline to 6 months & 12 months
6 Minute Hall Walk DistanceBaseline to 6 months & 12 months
Quality of Life MeasureBaseline to 6 months & 12 monthsEQ5D-5L & Minnesota Living with HF
MortalityBaseline to 6 months & 12 months
Heart Failure AdmissionsBaseline to 6 months & 12 months
Reduction of LVEFBaseline to 6 months & 12 months

Other

MeasureTime frameDescription
Safety:Pocket infection requiring extending hospitalization > 24 hours or requiring surgical interventionBaseline to 12 months
Safety:Lead(s) dislodgement requiring repositioning or cessation of CRTBaseline to 12 months
Safety:Cardiac tamponade requiring interventionBaseline to 12 months
Safety:Phrenic nerve stimulationBaseline to 12 months
Safety: LVendo CRT: specific system placement procedure related adverse eventsBaseline to 12 monthsSafety
Thromboembolic Events Investigator deemed to be directly related to the therapyBaseline to 12 monthsSafety

Countries

Canada

Outcome results

None listed