Brief summary

A comparative study was conducted and the patient underwent a conventional urodynamic study. In order to successfully determine if the Air-Charged (AC) and Water-Perfused (WP) measurements are equivalent, the two sources of intravesical pressure (Pves) and abdominal pressure (Pabd) were collected concurrently at various fill volumes for the bladder.

Detailed description

The objective of this study was to compare the use of water-filled and air-charged catheters in determining equivalency between the two technologies during cystometric assessment. A total of 25 patients (9M/16F) were recruited. All patients underwent cough and Valsalva manoeuvre pressure tests to measure vesicle pressure (Pves) and abdominal pressure (Pabd). A single dual-lumen catheter (T-DOC 7Fr Air-Charged® catheter) was used to record air and water pressures simultaneously. The primary outcome was to determine if the maximum pressures during Valsalva manoeuvres, as measured with a single dual-lumen water-perfused and air-charged catheter, are equivalent when the bladder is filled to 200 cc during a urodynamic evaluation. Exploratory endpoints included the following: 1. To determine if maximum pressures for cough, as measured with a single dual-lumen water-perfused and air-charged catheter, are equivalent when the bladder is filled to 100, 200 and Maximum Bladder Capacity (MBC) cc during a urodynamic evaluation. 2. To determine if maximum pressures for Valsalva manoeuvres, as measured with a single dual-lumen water-perfused and air-charged catheter, are equivalent when the bladder is filled to 100 and MBC cc during a urodynamic evaluation (as well as 200 cc which is the primary objective). 3. To determine if the maximum voiding pressure, as measured with a single dual-lumen water-perfused and air-charged catheter, are equivalent. 4. To determine if the clinical impressions of the urodynamic study are equivalent for the water-perfused and air-charged catheters. 5. To determine if the compliance of the bladder is equivalent when measured by air-charged catheters as compared to water-perfused catheters.

Interventions

DEVICETDOC air-charged catheter

Urodynamic study utilizing a single catheter technique to measure WP & AC measurements

Sponsors

Laborie Medical Technologies Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients normally indicated for urodynamic evaluations

Exclusion criteria

* Patients who suffer from bladder infections (not including patients with asymptomatic bacteruria, prophylaxis with an antibiotic is at the discretion of the physician) * Patients who suffer from strictures in the urethra * Patients who are pregnant * Patients who require the use of a suprapubic catheter

Design outcomes

Primary

MeasureTime frameDescription
Maximum Vesical Pressure During Valsalva ManoeuvresMeasured during a single urodynamic evaluationMaximum vesical pressure during Valsalva manoeuvres was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.
Maximum Abdominal Pressure During Valsalva ManoeuvresMeasured during a single urodynamic evaluationMaximum abdominal pressure during Valsalva manoeuvres was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.
Maximum Detrusor Pressure at Valsalva ManoeuvresMeasured during a single urodynamic evaluationMaximum detrusor pressure during Valsalva manoeuvres was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.

Secondary

MeasureTime frameDescription
Maximum Vesical Pressure During CoughsMeasured during a single urodynamic evaluationMaximum vesical pressure during coughs was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.
Maximum Abdominal Pressure During CoughsMeasured during a single urodynamic evaluationMaximum abdominal pressure during coughs was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.
Maximum Detrusor Pressure During CoughsMeasured during a single urodynamic evaluationMaximum detrusor pressure during coughs was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.

Countries

Germany

Participant flow

Participants by arm

ArmCount
Urodynamics With AC and WP
Patients underwent a conventional urodynamics study utilizing a single catheter technique TDOC air-charged catheter: Urodynamic study utilizing a single catheter technique to measure WP & AC measurements
25
Total25

Withdrawals & dropouts

PeriodReasonFG000
Overall StudyStudyTechnical Difficulties4

Baseline characteristics

CharacteristicUrodynamics With AC and WP
Age, Continuous43.3 years
Region of Enrollment
Germany
25 Participants
Sex: Female, Male
Female
16 Participants
Sex: Female, Male
Male
9 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 25
other
Total, other adverse events
1 / 25
serious
Total, serious adverse events
0 / 25

Outcome results

Primary

Maximum Abdominal Pressure During Valsalva Manoeuvres

Maximum abdominal pressure during Valsalva manoeuvres was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.

Time frame: Measured during a single urodynamic evaluation

ArmMeasureValue (MEAN)Dispersion
Urodynamics With AFCMaximum Abdominal Pressure During Valsalva Manoeuvres37.93 cmH2OStandard Deviation 21.7
Urodynamics With WFCMaximum Abdominal Pressure During Valsalva Manoeuvres38.11 cmH2OStandard Deviation 22.04
Primary

Maximum Detrusor Pressure at Valsalva Manoeuvres

Maximum detrusor pressure during Valsalva manoeuvres was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.

Time frame: Measured during a single urodynamic evaluation

ArmMeasureValue (MEAN)Dispersion
Urodynamics With AFCMaximum Detrusor Pressure at Valsalva Manoeuvres1.72 cmH2OStandard Deviation 3.85
Urodynamics With WFCMaximum Detrusor Pressure at Valsalva Manoeuvres1.65 cmH2OStandard Deviation 3.39
Primary

Maximum Vesical Pressure During Valsalva Manoeuvres

Maximum vesical pressure during Valsalva manoeuvres was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.

Time frame: Measured during a single urodynamic evaluation

ArmMeasureValue (MEAN)Dispersion
Urodynamics With AFCMaximum Vesical Pressure During Valsalva Manoeuvres39.31 cmH2OStandard Deviation 23.02
Urodynamics With WFCMaximum Vesical Pressure During Valsalva Manoeuvres39.44 cmH2OStandard Deviation 23.34
Secondary

Maximum Abdominal Pressure During Coughs

Maximum abdominal pressure during coughs was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.

Time frame: Measured during a single urodynamic evaluation

ArmMeasureValue (MEAN)Dispersion
Urodynamics With AFCMaximum Abdominal Pressure During Coughs60.71 cmH2OStandard Deviation 35.66
Urodynamics With WFCMaximum Abdominal Pressure During Coughs63.01 cmH2OStandard Deviation 38.67
Secondary

Maximum Detrusor Pressure During Coughs

Maximum detrusor pressure during coughs was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.

Time frame: Measured during a single urodynamic evaluation

ArmMeasureValue (MEAN)Dispersion
Urodynamics With AFCMaximum Detrusor Pressure During Coughs3.89 cmH2OStandard Deviation 9.44
Urodynamics With WFCMaximum Detrusor Pressure During Coughs6.83 cmH2OStandard Deviation 7.82
Secondary

Maximum Vesical Pressure During Coughs

Maximum vesical pressure during coughs was measured with an air-filled catheter and the water pressure was measured from the fill port. Air-filled catheter and water pressure measurements were compared.

Time frame: Measured during a single urodynamic evaluation

ArmMeasureValue (MEAN)Dispersion
Urodynamics With AFCMaximum Vesical Pressure During Coughs64.59 cmH2OStandard Deviation 39.21
Urodynamics With WFCMaximum Vesical Pressure During Coughs69.65 cmH2OStandard Deviation 43.25