Skip to content

Early Detection of Lymphedema With Bio-Electrical Impedance Analysis in Patients After Breast Cancer Surgery

Early Detection of Lymphedema With Bio-Electrical Impedance Analysis in Patients After Breast Cancer Surgery

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02748746
Acronym
BIA
Enrollment
0
Registered
2016-04-22
Start date
2018-08-31
Completion date
2019-11-30
Last updated
2020-06-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lymphedema, Breast Cancer

Keywords

Lymphedema, Electric Impedance, Breast Cancer

Brief summary

Bio-electrical impedance analysis and Tissue Dielectric Constant measurements are objective methods in clinical usage to detect lymphedema in early stage. The aim of this study is to reveal comparative relation these two methods on detecting lymphedema in an early stage.The another aim of this study is to determine impedance ratios and lymphedema index (L-dex) by using bio-electrical impedance analysis in patients after breast cancer surgery.

Detailed description

Lymphedema is characterized by accumulation of protein rich fluid in interstitial spaces. It is also a chronic condition that needs lifelong care. Untreated lymphedema leads to chronic inflammation, cellulitis, pain, tiredness, cosmetic deformities, restriction of individual's motion, mobility problems and dysfunctional use of affected extremity. Undiagnosed lymphedema worsens gradually thus detecting lymphedema in an early stage have a place in matter. It was indicated that early treatment of lymphedema improves treatment outcomes. Bio-Electrical Impedance Analysis is a non-invasive method that measures extracellular fluid proportion and impedance of related extremity by an advanced low intensity electrical current passes through body. It was stated that Bio-Electrical Impedance Analysis measures impedance ratio and it is useful in detecting lymphedema in an early stage. Bio-Electrical Impedance Analysis (BIA) gives important informations in the assessment of lymphedema by measuring directly tissue fluid changes. Lymphedema Index (L-dex) is found by dividing impedance ratios of unaffected extremity to affected extremity's impedance ratio with bio-electrical impedance analysis. Impedance of extremity lessens by developing lymphedema so L-dex value gets higher. Tissue Dielectric Constant (TDC) is an objective and non-invasive measurement method to evaluate early tissue fluid changes. A 300 megahertz signal is generated in a control unit and transmitted to tissue by probe. Reflected electromagnetic wave depends on dielectric constant of tissue. Free and bound water molecules proportion in tissue effect tissue dielectric constant. Reflected electromagnetic wave is processed in the control unit and relative tissue dielectric constant is calculated. Dielectric constant of pure water is 78.5 in room temperature. The Scale ranges between 1-80. It was stated that comparing affected and unaffected extremities regarding lymphedema existence with TDC measurement, TDC value was higher than 1.2 in the experimental group. In the control group, TDC value was lower than 1.2 . It was also emphasized that this proportion is probably valuable on assessment of upper extremity lymphedema. TDC could be done in different depth. 0.5, 1.5, 2.5 and 5.0 mm probes are possible for usage.In this study, Moisture Meter-D compact (MMDc) device will be used for assessment. It allows evaluation in 2.5 mm depth. In this study, TDC will be applied to upper extremity both affected and unaffected side. 6 cm lower point of cubital crease, 8 cm upper point of cubital crease and 10 cm lower point of armpit will be marked on two sides with a soft pen before measurement. Between 18-65 years old total 60 women will be recruited into the study in 3 separate groups.The first group will contain patients who had breast cancer surgery yet having no lymphedema. The inclusion criteria for involving the first group is surgery time. No one will be involved into the first group if surgery was applied 18 months ago before enrollment to this study. The second group will contain patients who had breast cancer surgery and having upper extremity lymphedema. The third group will contain healthy women. The aim of this study whether BIA and TDC methods are in capable of detecting lymphedema in an early stage. Measurements will be done at baseline, 6th month and 12th month. Exclusion criteria include being involuntary to recruit the study, bilaterally breast surgery history, having bilaterally upper extremity lymphedema, active infection, active chemotherapy and radiotherapy process, being in malignity period, and having mentally and cognitive disorders. Lymphedema treatment may be quite costly due to materials used in the treatment and special producted compression stockings. If we take into account that compression stocking must change every six months, it carries too much importance regarding cost-effectivity that preventing lymphedema before manifesting.Even if lymphedema manifested already, detecting lymphedema in an early stage before aggravation improves treatment outcomes and individual's quality of life.

Interventions

DEVICEBio Impedance Analysis Measurement

Self-adhesive electrodes will be placed to related side's hand dorsum and foot dorsum regarding to calculate for left or right upper extremity's impedance. After completing the measurements for each side, results will be saved by device and documented on paper. A patient total measurement time lasts approximately 3 minutes.

In this study, TDC device (Moisture Meter-D compact-MMDc will be implemented to upper extremity both affected and unaffected side. 6 cm lower point of cubital crease, 8 cm upper point of cubital crease and 10 cm lower point of armpit will be marked on two sides with a soft pen before measurement. A gentle pressure must required to have accurate sub-tissue fluid percent. Triplicate measurements will be done and taken those average value for each point in order to reach sensitive screening. Computer software simultaneously save these measurements results automatically. A patient total measurement time approximately lasts 5 minutes.

Sponsors

The Scientific and Technological Research Council of Turkey
CollaboratorOTHER
Abant Izzet Baysal University
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* Being Voluntary to recruit study

Exclusion criteria

* Being involuntary to recruit the study * Bilaterally Breast Surgery History * Having Bilaterally Upper Extremity Lymphedema * Active Infection Existence * Active Chemotherapy * Active Radiotherapy * Being in Malignity Period * Having Mentally and Cognitive Disorders

Design outcomes

Primary

MeasureTime frameDescription
Investigation of early detection of lymphedema after breast cancer surgery with Bio Electrical Impedance Analysis (BIA)12 monthsTo investigate efficacy of Bio electrical Impedance analysis method on early onset of upper extremity lymphedema.

Secondary

MeasureTime frameDescription
Investigation of symptom related quality of life with LymQoL12 monthsSymptom related quality of life questionnaire (LympQoL) will be implemented to 60 women in 3 different time frames (baseline, 6th month and 12th month). Purpose of this whether symptomatic severity changes effect the quality of life.

Other

MeasureTime frameDescription
Investigation of early detection of lymphedema after breast cancer surgery with Tissue Dielectric Constant (TDC) measurement12 monthsTo investigate efficacy of Tissue Dielectric Constant (TDC) measurement method on early onset of upper extremity lymphedema.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026