Clinical Study to Evaluate CryoBalloon™ Full and Swipe Ablation Systems for Ablation of Human Esophageal Epithelium

Clinical Study to Evaluate the CryoBalloon™ Full and Swipe Ablation Systems for Ablation of Human Esophageal Epithelium

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02729753
Enrollment
10
Registered
2016-04-06
Start date
2016-04-30
Completion date
2016-10-30
Last updated
2022-04-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Esophageal Cancer

Brief summary

This study will evaluate the C2 CryoBalloon™ Full and Swipe Ablation Systems for the ablation of human esophageal epithelium in patients scheduled to undergo esophagectomy for reasons unrelated to the objective of the study

Detailed description

The primary outcomes for the study are the safety and treatment effect of the C2 CryoBalloon™ Ablation System. An esophagectomy will be performed as scheduled following the ablation procedure; histopathological analysis of surgically-resected specimens will be performed.

Interventions

DEVICECryoBalloon™ Full Ablation System

Tissue Ablation using CryoBalloon™ Full Ablation System

DEVICECryoBalloon™ Swipe Ablation System

Tissue Ablation using CryoBalloon™ Swipe Ablation System

Sponsors

Pentax Medical
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
BASIC_SCIENCE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Minimum of one 3cm area of non-ulcerated columnar-lined esophagus or squamous-lined tissue suitable for ablation * Older than 18 years of age * Requires a clinically necessary esophagectomy for esophageal cancer or other indications.

Exclusion criteria

* Patient has esophageal narrowing limiting access to the intended sites of ablation

Design outcomes

Primary

MeasureTime frameDescription
Safety of the CryoBalloon™ Full and Swipe Ablation System2 weeksNumber of participants with serious, device-related adverse events after treatment with the CryoBalloon™ Swipe Ablation System
Effect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems2 weeksEvaluated by depth and uniformity of ablation effect in the esophagus based on histopathologic assessment. Dose response by effect of ablation to submucosa: 0: Normal 1. Inflammatory cell infiltration 2. Separation with inflammation 3. Edema and Necrosis

Secondary

MeasureTime frameDescription
Device Performance: Average Procedure TimeMinutes from start to end of procedureAverage Procedure time as measured from start to finish of ablation.
Device Performance: Ease of Deployment of DeviceMinutes, from start to end of procedureLikert Scale measuring physician satisfaction. 0 (worst) to 10 (best)

Countries

United States

Participant flow

Recruitment details

Patients scheduled for esophagectomy for esophageal cancer or other indications unrelated to the objective of this study were approached to allow for use of cryoballoon ablation in area to be resected prior to surgery.

Participants by arm

ArmCount
CryoBalloon™ Swipe Ablation System
To evaluate CryoBalloon™ Full Ablation System for the ablation of 90 degrees of human esophageal epithelium in patients scheduled to undergo esophagectomy.
6
CryoBalloon™ Full Ablation System
To evaluate CryoBalloon™ Full Ablation System for the ablation of 360 degrees of human esophageal epithelium in patients scheduled to undergo esophagectomy.
3
Total9

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudyDevice Malfunction. No units in stock.01

Baseline characteristics

CharacteristicTotalCryoBalloon™ Swipe Ablation SystemCryoBalloon™ Full Ablation System
Age, Continuous64 years69 years57 years
BMI26 kg/m^226.3 kg/m^223.3 kg/m^2
History of Barrett's Esophagus4 Participants4 Participants0 Participants
History of GERD5 Participants4 Participants1 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
0 Participants0 Participants0 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
1 Participants0 Participants1 Participants
Race (NIH/OMB)
White
8 Participants6 Participants2 Participants
Region of Enrollment
Netherlands
3 Participants1 Participants2 Participants
Region of Enrollment
United States
6 Participants5 Participants1 Participants
Sex: Female, Male
Female
1 Participants1 Participants0 Participants
Sex: Female, Male
Male
8 Participants5 Participants3 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 30 / 6
other
Total, other adverse events
1 / 30 / 6
serious
Total, serious adverse events
0 / 30 / 6

Outcome results

Primary

Effect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems

Evaluated by depth and uniformity of ablation effect in the esophagus based on histopathologic assessment. Dose response by effect of ablation to submucosa: 0: Normal 1. Inflammatory cell infiltration 2. Separation with inflammation 3. Edema and Necrosis

Time frame: 2 weeks

Population: Submucosal evaluation done for patients at differing doses.

ArmMeasureGroupValue (NUMBER)
CryoBalloon™ Swipe Ablation SystemEffect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems0.5mm/sec : Immediate esophagectomy2 units on a scale
CryoBalloon™ Swipe Ablation SystemEffect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems0.5mm/sec : Esophagectomy 5 days Post3 units on a scale
CryoBalloon™ Swipe Ablation SystemEffect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems0.6mm/sec : Immediate esophagectomy1 units on a scale
CryoBalloon™ Full Ablation SystemEffect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems0.5mm/sec : Esophagectomy 5 days Post1 units on a scale
CryoBalloon™ Full Ablation SystemEffect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems0.9mm/sec : Immediate esophagectomy1 units on a scale
CryoBalloon™ Full Ablation SystemEffect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems0.6mm/sec : Immediate esophagectomy2 units on a scale
CryoBalloon™ Full Ablation SystemEffect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems0.8mm/sec :Immediate esophagectomy2 units on a scale
CryoBalloon™ Full Ablation SystemEffect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems0.5mm/sec : Immediate esophagectomy0 units on a scale
CryoBalloon™ Full Ablation SystemEffect of Ablation to Submucosa at Different Depth of Tissue Ablation Using the CryoBalloon™ Full and Swipe Ablation Systems0.8mm/sec : Esophagectomy 5 days Post1 units on a scale
Primary

Safety of the CryoBalloon™ Full and Swipe Ablation System

Number of participants with serious, device-related adverse events after treatment with the CryoBalloon™ Swipe Ablation System

Time frame: 2 weeks

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
CryoBalloon™ Swipe Ablation SystemSafety of the CryoBalloon™ Full and Swipe Ablation System0 Participants
CryoBalloon™ Full Ablation SystemSafety of the CryoBalloon™ Full and Swipe Ablation System0 Participants
Secondary

Device Performance: Average Procedure Time

Average Procedure time as measured from start to finish of ablation.

Time frame: Minutes from start to end of procedure

ArmMeasureValue (MEAN)
CryoBalloon™ Swipe Ablation SystemDevice Performance: Average Procedure Time5 Minutes
CryoBalloon™ Full Ablation SystemDevice Performance: Average Procedure Time4.8 Minutes
Secondary

Device Performance: Ease of Deployment of Device

Likert Scale measuring physician satisfaction. 0 (worst) to 10 (best)

Time frame: Minutes, from start to end of procedure

Population: CryoBalloon Full and Swipe Ablation Systems used by physicians to perform ablation

ArmMeasureValue (MEAN)
CryoBalloon™ Swipe Ablation SystemDevice Performance: Ease of Deployment of Device9 units on a scale
CryoBalloon™ Full Ablation SystemDevice Performance: Ease of Deployment of Device7.8 units on a scale

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026