Myopia
Conditions
Brief summary
The aim of this non-dispensing study is to evaluate the clinical performance of different hydrogel contact lens designs.
Detailed description
This is a 35-subject, double masked, randomized, contra lateral, non-dispensing fitting trial comparing different hydrogel lens materials. For each study, this study will involve 2 visits: lens dispensing (baseline) and 1 hour post lens settling. Each subject will be randomized to wear the test and control lenses, in the right or left eye, in a series of four short fitting comparisons as follows: Pair 1 (P1): filcon IV I (Base Curve (BC) 8.6) and ocufilcon D Pair 2 (P2): filcon IV I (Base Curve (BC) 8.7) and ocufilcon D Pair 3 (P3): methafilcon A (Base Curve (BC) 8.6) and ocufilcon D Pair 4 (P4): methafilcon A (Base Curve (BC)8.7) and somofilcon A
Interventions
control lens
control lens
test lens
control lens
control lens
test lens
Sponsors
Study design
Eligibility
Inclusion criteria
A person is eligible for inclusion in the study if he/she: * Is between 18 and 40 years of age (inclusive). * Has had a self-reported visual exam in the last two years. * Is an adapted soft CL (Contact Lens) wearer. * Has a CL spherical prescription between - 1.00 and - 6.00 (inclusive) * Has a spectacle cylinder up to 0.75D (Diopters) in each eye. * Can achieve best corrected spectacle distance visual acuity of 20/25 (0.10 logMAR) or better in each eye. * Can achieve a distance visual acuity of 20/30 (0.18 logMAR) or better in each eye with the study contact lenses. * Has clear corneas and no active ocular disease. * Has read, understood and signed the information consent letter. * Patient contact lens refraction should fit within the available parameters of the study lenses. * Is willing to comply with the wear schedule. * Is willing to comply with the visit schedule.
Exclusion criteria
A person will be excluded from the study if he/she: * Has never worn contact lenses before. * Currently wears rigid gas permeable contact lenses. * Has a history of not achieving comfortable CL wear (5 days per week; \> 8 hours/day) * Has a CL prescription outside the range of - 1.00 to - 6.00D * Has a spectacle cylinder ≥1.00D of cylinder in either eye. * Has contact lens best corrected distance vision worse than 20/25 (0.10 logMAR) in either eye. * Presence of clinically significant (grade 2-4) anterior segment abnormalities. * Presence of ocular or systemic disease or need of medications which might interfere with contact lens wear. * Slit lamp findings that would contraindicate contact lens wear such as: * Pathological dry eye or associated findings * Pterygium, pinguecula, or corneal scars within the visual axis * Neovascularization \> 0.75 mm in from of the limbus * Giant papillary conjunctivitis (GPC) worse than grade 1 * Anterior uveitis or iritis (past or present) * Seborrheic eczema, Seborrheic conjunctivitis * History of corneal ulcers or fungal infections * Poor personal hygiene * Has a known history of corneal hypoesthesia (reduced corneal sensitivity) * Has aphakia, keratoconus or a highly irregular cornea. * Has Presbyopia or has dependence on spectacles for near work over the contact lenses. * Has undergone corneal refractive surgery. * Is participating in any other type of eye related clinical or research study.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Centration - Pair One | Baseline and 1 hour | Centration for filcon IV I (Base Curve (BC) 8.6) / ocufilcon D (pair one) is assessed. (optimum, decentration acceptable, decentration unacceptable). |
| Centration - Pair Two | Baseline and 1 hour | Centration for filcon IV I (Base Curve (BC) 8.7) / ocufilcon D (pair two) is assessed. (optimum, decentration acceptable, decentration unacceptable). |
| Centration - Pair Three | Baseline and 1 hour | Centration for methafilcon A (Base Curve (BC) 8.6) / ocufilcon D (pair three) is assessed. (optimum, decentration acceptable, decentration unacceptable). |
| Centration - Pair Four | Baseline and 1 hour | Centration for methafilcon A (Base Curve (BC) 8.7) / somofilcon A (pair four) is assessed. (optimum, decentration acceptable, decentration unacceptable). |
| Post-blink Movement - Pair One | Baseline | Post-blink movement for filcon IV I (BC 8.6) / ocufilcon D (pair one) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement). |
| Post-blink Movement - Pair Two | Baseline | Post-blink movement for filcon IV I (BC 8.7) / ocufilcon D (pair two) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement). |
| Post-blink Movement - Pair Three | Baseline | Post-blink movement for methafilcon A (BC 8.6) / ocufilcon D (pair three) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement). |
| Post-blink Movement - Pair Four | Baseline | Post-blink movement for methafilcon A (BC 8.7) / somofilcon A (pair four) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement). |
| Lens Tightness - Pair One | Baseline and 1 hour | Lens tightness on push on test for filcon IV I (BC 8.6) / ocufilcon D (pair one) is assessed. (0% - 100%, 100%=No movement, 50%=Optimum 0%=Falls from cornea without lid support) |
| Lens Tightness - Pair Two | Baseline and 1 hour | Lens tightness on push on test for filcon IV I (BC 8.7) / ocufilcon D (pair two) is assessed. (0% - 100%, 100%=No movement, 50%=Optimum 0%=Falls from cornea without lid support) |
| Lens Tightness - Pair Three | Baseline and 1 hour | Lens tightness on push on test for methafilcon A (BC 8.6) / ocufilcon D (pair three) is assessed. (0% - 100%, 100%=No movement, 50%=Optimum 0%=Falls from cornea without lid support) |
| Lens Tightness - Pair Four | Baseline and 1 hour | Lens tightness on push on test for methafilcon A (BC 8.7) / somofilcon A (pair four) is assessed. (0% - 100%, 100%=No movement, 50%=Optimum 0%=Falls from cornea without lid support) |
| Overall Fit Preference - Pair One | Baseline and 1 hour | Investigator's lens fit acceptance / acceptability for filcon IV I (BC 8.6) / ocufilcon D (pair one) is assessed. Three choices: filcon IV I (BC 8.6), ocufilcon D, or no preference. |
| Overall Fit Acceptance - Pair Two | Baseline and 1 hour | Investigator's lens fit acceptance / acceptability for filcon IV I (BC 8.7) / ocufilcon D (pair two) is assessed. Three choices: filcon IV I (BC 8.7), ocufilcon D, or no preference. |
| Overall Fit Acceptance - Pair Three | Baseline and 1 hour | Investigator's lens fit acceptance / acceptability for methafilcon A (BC 8.6) / ocufilcon D (pair three) is assessed. Three choices: methafilcon A (BC 8.6), ocufilcon D, or no preference. |
| Overall Fit Acceptance - Pair Four | Baseline and 1 hour | Investigator's lens fit acceptance / acceptability for methafilcon A (BC 8.7) / somofilcon A (pair four) is assessed. Three choices: methafilcon A (BC 8.7), somofilcon A, or no preference. |
Countries
Mexico
Participant flow
Participants by arm
| Arm | Count |
|---|---|
| Overall Participants Participants were randomized to a test and control lens for each of the four lens pair in a contralateral design. | 35 |
| Total | 35 |
Baseline characteristics
| Characteristic | Overall Participants |
|---|---|
| Age, Continuous | 22.5 years STANDARD_DEVIATION 2.8 |
| Sex: Female, Male Female | 23 Participants |
| Sex: Female, Male Male | 12 Participants |
Adverse events
| Event type | EG000 affected / at risk |
|---|---|
| deaths Total, all-cause mortality | 0 / 35 |
| other Total, other adverse events | 0 / 35 |
| serious Total, serious adverse events | 0 / 35 |
Outcome results
Centration - Pair Four
Centration for methafilcon A (Base Curve (BC) 8.7) / somofilcon A (pair four) is assessed. (optimum, decentration acceptable, decentration unacceptable).
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Four | Baseline - Optimum | 35 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Four | Baseline - Decentration acceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Four | Baseline - Decentration unacceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Four | 1 hour - Optimum | 35 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Four | 1 hour - Decentration acceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Four | 1 hour - Decentration unacceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Four | 1 hour - Decentration acceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Four | Baseline - Optimum | 35 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Four | 1 hour - Optimum | 35 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Four | Baseline - Decentration acceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Four | 1 hour - Decentration unacceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Four | Baseline - Decentration unacceptable | 0 number of eyes |
Centration - Pair One
Centration for filcon IV I (Base Curve (BC) 8.6) / ocufilcon D (pair one) is assessed. (optimum, decentration acceptable, decentration unacceptable).
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair One | Baseline - Decentration unacceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair One | 1 hour - Decentration acceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair One | Baseline - Decentration acceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair One | 1 hour - Decentration unacceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair One | 1 hour - Optimum | 35 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair One | Baseline - Optimum | 35 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair One | 1 hour - Optimum | 35 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair One | Baseline - Decentration acceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair One | Baseline - Decentration unacceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair One | Baseline - Optimum | 35 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair One | 1 hour - Decentration acceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair One | 1 hour - Decentration unacceptable | 0 number of eyes |
Centration - Pair Three
Centration for methafilcon A (Base Curve (BC) 8.6) / ocufilcon D (pair three) is assessed. (optimum, decentration acceptable, decentration unacceptable).
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Three | Baseline - Optimum | 35 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Three | Baseline - Decentration acceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Three | Baseline - Decentration unacceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Three | 1 hour - Optimum | 35 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Three | 1 hour - Decentration acceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Three | 1 hour - Decentration unacceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Three | 1 hour - Decentration acceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Three | Baseline - Optimum | 35 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Three | 1 hour - Optimum | 35 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Three | Baseline - Decentration acceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Three | 1 hour - Decentration unacceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Three | Baseline - Decentration unacceptable | 0 number of eyes |
Centration - Pair Two
Centration for filcon IV I (Base Curve (BC) 8.7) / ocufilcon D (pair two) is assessed. (optimum, decentration acceptable, decentration unacceptable).
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Two | Baseline - Optimum | 35 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Two | Baseline - Decentration acceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Two | Baseline - Decentration unacceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Two | 1 hour - Optimum | 35 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Two | 1 hour - Decentration acceptable | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Centration - Pair Two | 1 hour - Decentration unacceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Two | 1 hour - Decentration acceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Two | Baseline - Optimum | 35 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Two | 1 hour - Optimum | 35 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Two | Baseline - Decentration acceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Two | 1 hour - Decentration unacceptable | 0 number of eyes |
| Ocufilcon D - Pair One | Centration - Pair Two | Baseline - Decentration unacceptable | 0 number of eyes |
Lens Tightness - Pair Four
Lens tightness on push on test for methafilcon A (BC 8.7) / somofilcon A (pair four) is assessed. (0% - 100%, 100%=No movement, 50%=Optimum 0%=Falls from cornea without lid support)
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Lens Tightness - Pair Four | Baseline | 61.1 percent lens tightness | Standard Deviation 20.3 |
| Filcon IV I (BC 8.6) - Pair One | Lens Tightness - Pair Four | 1 hour | 56.3 percent lens tightness | Standard Deviation 12.4 |
| Ocufilcon D - Pair One | Lens Tightness - Pair Four | Baseline | 66.7 percent lens tightness | Standard Deviation 19.9 |
| Ocufilcon D - Pair One | Lens Tightness - Pair Four | 1 hour | 56.6 percent lens tightness | Standard Deviation 11.6 |
Lens Tightness - Pair One
Lens tightness on push on test for filcon IV I (BC 8.6) / ocufilcon D (pair one) is assessed. (0% - 100%, 100%=No movement, 50%=Optimum 0%=Falls from cornea without lid support)
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Lens Tightness - Pair One | Baseline | 62.8 Percent lens tightness | Standard Deviation 16.2 |
| Filcon IV I (BC 8.6) - Pair One | Lens Tightness - Pair One | 1 hour | 64.9 Percent lens tightness | Standard Deviation 15.9 |
| Ocufilcon D - Pair One | Lens Tightness - Pair One | Baseline | 57.1 Percent lens tightness | Standard Deviation 15.8 |
| Ocufilcon D - Pair One | Lens Tightness - Pair One | 1 hour | 57.1 Percent lens tightness | Standard Deviation 14.5 |
Lens Tightness - Pair Three
Lens tightness on push on test for methafilcon A (BC 8.6) / ocufilcon D (pair three) is assessed. (0% - 100%, 100%=No movement, 50%=Optimum 0%=Falls from cornea without lid support)
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Lens Tightness - Pair Three | Baseline | 54.0 percent lens tightness | Standard Deviation 7.8 |
| Filcon IV I (BC 8.6) - Pair One | Lens Tightness - Pair Three | 1 hour | 54.3 percent lens tightness | Standard Deviation 8.5 |
| Ocufilcon D - Pair One | Lens Tightness - Pair Three | Baseline | 54.3 percent lens tightness | Standard Deviation 10.7 |
| Ocufilcon D - Pair One | Lens Tightness - Pair Three | 1 hour | 51.2 percent lens tightness | Standard Deviation 6.6 |
Lens Tightness - Pair Two
Lens tightness on push on test for filcon IV I (BC 8.7) / ocufilcon D (pair two) is assessed. (0% - 100%, 100%=No movement, 50%=Optimum 0%=Falls from cornea without lid support)
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (MEAN) | Dispersion |
|---|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Lens Tightness - Pair Two | Baseline | 57.0 percent lens tightness | Standard Deviation 17.1 |
| Filcon IV I (BC 8.6) - Pair One | Lens Tightness - Pair Two | 1 hour | 57.7 percent lens tightness | Standard Deviation 14.8 |
| Ocufilcon D - Pair One | Lens Tightness - Pair Two | Baseline | 52.3 percent lens tightness | Standard Deviation 16.5 |
| Ocufilcon D - Pair One | Lens Tightness - Pair Two | 1 hour | 56.6 percent lens tightness | Standard Deviation 17.1 |
Overall Fit Acceptance - Pair Four
Investigator's lens fit acceptance / acceptability for methafilcon A (BC 8.7) / somofilcon A (pair four) is assessed. Three choices: methafilcon A (BC 8.7), somofilcon A, or no preference.
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Overall Fit Acceptance - Pair Four | 1 hour | 12 number of subjects |
| Filcon IV I (BC 8.6) - Pair One | Overall Fit Acceptance - Pair Four | Baseline | 9 number of subjects |
| Ocufilcon D - Pair One | Overall Fit Acceptance - Pair Four | 1 hour | 8 number of subjects |
| Ocufilcon D - Pair One | Overall Fit Acceptance - Pair Four | Baseline | 5 number of subjects |
| No Preference | Overall Fit Acceptance - Pair Four | 1 hour | 15 number of subjects |
| No Preference | Overall Fit Acceptance - Pair Four | Baseline | 21 number of subjects |
Overall Fit Acceptance - Pair Three
Investigator's lens fit acceptance / acceptability for methafilcon A (BC 8.6) / ocufilcon D (pair three) is assessed. Three choices: methafilcon A (BC 8.6), ocufilcon D, or no preference.
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Overall Fit Acceptance - Pair Three | Baseline | 12 number of subjects |
| Filcon IV I (BC 8.6) - Pair One | Overall Fit Acceptance - Pair Three | 1 hour | 6 number of subjects |
| Ocufilcon D - Pair One | Overall Fit Acceptance - Pair Three | Baseline | 6 number of subjects |
| Ocufilcon D - Pair One | Overall Fit Acceptance - Pair Three | 1 hour | 10 number of subjects |
| No Preference | Overall Fit Acceptance - Pair Three | Baseline | 17 number of subjects |
| No Preference | Overall Fit Acceptance - Pair Three | 1 hour | 19 number of subjects |
Overall Fit Acceptance - Pair Two
Investigator's lens fit acceptance / acceptability for filcon IV I (BC 8.7) / ocufilcon D (pair two) is assessed. Three choices: filcon IV I (BC 8.7), ocufilcon D, or no preference.
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Overall Fit Acceptance - Pair Two | Baseline | 13 number of subjects |
| Filcon IV I (BC 8.6) - Pair One | Overall Fit Acceptance - Pair Two | 1 hour | 13 number of subjects |
| Ocufilcon D - Pair One | Overall Fit Acceptance - Pair Two | Baseline | 9 number of subjects |
| Ocufilcon D - Pair One | Overall Fit Acceptance - Pair Two | 1 hour | 6 number of subjects |
| No Preference | Overall Fit Acceptance - Pair Two | Baseline | 13 number of subjects |
| No Preference | Overall Fit Acceptance - Pair Two | 1 hour | 16 number of subjects |
Overall Fit Preference - Pair One
Investigator's lens fit acceptance / acceptability for filcon IV I (BC 8.6) / ocufilcon D (pair one) is assessed. Three choices: filcon IV I (BC 8.6), ocufilcon D, or no preference.
Time frame: Baseline and 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Overall Fit Preference - Pair One | Baseline | 4 number of subjects |
| Filcon IV I (BC 8.6) - Pair One | Overall Fit Preference - Pair One | 1 hour | 3 number of subjects |
| Ocufilcon D - Pair One | Overall Fit Preference - Pair One | 1 hour | 17 number of subjects |
| Ocufilcon D - Pair One | Overall Fit Preference - Pair One | Baseline | 15 number of subjects |
| No Preference | Overall Fit Preference - Pair One | 1 hour | 15 number of subjects |
| No Preference | Overall Fit Preference - Pair One | Baseline | 16 number of subjects |
Post-blink Movement - Pair Four
Post-blink movement for methafilcon A (BC 8.7) / somofilcon A (pair four) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement).
Time frame: Baseline
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Minimum | 7 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Moderate | 3 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Optimum | 18 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Excessive | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Insufficient | 7 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Excessive | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Insufficient | 9 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Minimum | 11 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Optimum | 14 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Moderate | 1 number of eyes |
Post-blink Movement - Pair Four
Post-blink movement for methafilcon A (BC 8.7) / somofilcon A (pair four) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement).
Time frame: 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Optimum | 25 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Minimum | 7 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Moderate | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Insufficient | 3 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Four | Excessive | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Insufficient | 1 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Optimum | 24 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Excessive | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Minimum | 10 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Four | Moderate | 0 number of eyes |
Post-blink Movement - Pair One
Post-blink movement for filcon IV I (BC 8.6) / ocufilcon D (pair one) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement).
Time frame: Baseline
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Insufficient | 6 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Optimum | 16 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Excessive | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Moderate | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Minimum | 13 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Excessive | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Insufficient | 5 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Minimum | 2 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Optimum | 28 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Moderate | 0 number of eyes |
Post-blink Movement - Pair One
Post-blink movement for filcon IV I (BC 8.6) / ocufilcon D (pair one) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement).
Time frame: 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Minimum | 19 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Moderate | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Optimum | 14 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Excessive | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair One | Insufficient | 2 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Excessive | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Insufficient | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Minimum | 9 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Optimum | 26 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair One | Moderate | 0 number of eyes |
Post-blink Movement - Pair Three
Post-blink movement for methafilcon A (BC 8.6) / ocufilcon D (pair three) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement).
Time frame: Baseline
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Minimum | 8 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Insufficient | 1 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Optimum | 26 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Excessive | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Moderate | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Excessive | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Moderate | 3 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Insufficient | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Minimum | 9 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Optimum | 23 number of eyes |
Post-blink Movement - Pair Three
Post-blink movement for methafilcon A (BC 8.6) / ocufilcon D (pair three) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement).
Time frame: 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Minimum | 10 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Moderate | 1 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Optimum | 24 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Excessive | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Three | Insufficient | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Excessive | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Insufficient | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Minimum | 5 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Optimum | 28 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Three | Moderate | 2 number of eyes |
Post-blink Movement - Pair Two
Post-blink movement for filcon IV I (BC 8.7) / ocufilcon D (pair two) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement).
Time frame: 1 hour
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Minimum | 5 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Moderate | 3 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Optimum | 23 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Excessive | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Insufficient | 4 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Excessive | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Insufficient | 1 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Minimum | 13 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Optimum | 20 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Moderate | 1 number of eyes |
Post-blink Movement - Pair Two
Post-blink movement for filcon IV I (BC 8.7) / ocufilcon D (pair two) is assessed. (0-5 Likert scale, 0=Insufficient, unacceptable movement, 4=Excessive, unacceptable movement).
Time frame: Baseline
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Minimum | 7 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Moderate | 10 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Optimum | 15 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Excessive | 0 number of eyes |
| Filcon IV I (BC 8.6) - Pair One | Post-blink Movement - Pair Two | Insufficient | 3 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Excessive | 0 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Insufficient | 2 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Minimum | 16 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Optimum | 14 number of eyes |
| Ocufilcon D - Pair One | Post-blink Movement - Pair Two | Moderate | 3 number of eyes |