Performance Value of Research of Occult Gastrointestinal Bleeding by Immunoassay in the Diagnostic Process of Iron Deficiency Anemia in Patients Over 75 Years

Performance Value of Research of Occult Gastrointestinal Bleeding by Immunoassay in the Diagnostic Process of Iron Deficiency Anemia in Patients Over 75 Years

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02727075
Acronym
STRATAGANEMIE
Enrollment
79
Registered
2016-04-04
Start date
2016-07-31
Completion date
2019-09-05
Last updated
2025-03-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Occult Gastrointestinal Bleeding

Keywords

Occult Gastrointestinal Bleeding, Iron Deficiency Anemia, Aged 75 Years and Older

Brief summary

This study aims to characterize the diagnostic performance of immunological testing of occult gastrointestinal bleeding in stool in the population aged over 75 years with iron deficiency anemia. As secondary objectives, the study aims to: * determine a threshold of positivity optimizing the immunoassay performance for the study population, in accordance with the probabilities of error (false positives, false negatives) and weights (defined by expert consensus) allocated to these errors. * Assess the benefit of a double measure of bleeding (two stools) by immunoassay compared to a single measure.

Detailed description

Immunological testing will be performed systematically for each patient. Research of blood in fecal sample will be based on 2 methods: one based on a qualitative immunochromatographic method (such as HemSign4 technique, Servibio, France; or all other techniques used at AP-HP) and another quantitative immunoturbidimetric method (OC-Sensor, Eiken, Japan). They will be performed systematically with two fresh fecal samples for each patient, before coloscopy examination. Treating physicians will not be provided with the testing result. The diagnosis of reference will be established by experts based on the result of explorations (colonoscopy, coloscanner) and the patient's progression, blinded to the result of immunoassay. The intrinsic characteristics of the immunoassay (sensitivity, specificity...) will be determined with reference to this reference diagnosis, using a positivity threshold defined using expert consensus on the weights to be allocated to potential errors. 2 modeling scenarios (without vs with immunological testing) using decision trees based on prevalence and diagnostic performance observed and stochastic simulations.

Interventions

None listed

Sponsors

Assistance Publique - Hôpitaux de Paris
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
75 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Physical status score 3 or 4, aged 75 and older patient, (patients under guardianship may be included). * Iron deficiency anemia (Hb≤120 g/l for a woman or Hb≤130 g/l for a man), and nonregenerative anemia with reticulocytes \<120 000/mm3. * Patient who has indication for colonoscopy and / or colonography examination, whatever the results of gastroscopy if performed. * Have a health insurance. * Informed consent signed.

Exclusion criteria

* Hematemesis or melena * Life expectancy inferior to 12 months * Patient has difficulty in follow-up of study.

Design outcomes

Primary

MeasureTime frameDescription
Sensitivity of immunological test with OC-SENSOR suppliesAt baselineThe immunological test with OC-SENSOR supplies is a quantitative determination of hemoglobin, the method of detection of lower gastrointestinal hemorrhagic lesions of older population with iron deficiency anemia. Sensitivity of the immunological test will be calculated statistically.
Specificity of immunological test with OC-SENSOR suppliesAt baselineThe immunological test with OC-SENSOR supplies is a quantitative determination of hemoglobin, the method of detection of lower gastrointestinal hemorrhagic lesions of older population with iron deficiency anemia. Specificity of the immunological test will be calculated statistically.
Likelihood ratios of immunological test with OC-SENSOR suppliesAt baselineThe immunological test with OC-SENSOR supplies is a quantitative determination of hemoglobin, the method of detection of lower gastrointestinal hemorrhagic lesions of older population with iron deficiency anemia. Likelihood rations of the immunological test will be calculated statistically.

Secondary

MeasureTime frameDescription
Diagnostic PerformanceAt baselineDiagnostic Performance of predictive equation incorporating all individual data will be calculated statistically.
Comparing scenarios using decision treesAt baselineCompare using modeling (decision trees) the causal efficiency (number of origins of bleeding detected / number of coloscopy-colonoscopy performed) of two scenarios: without (base case) and with the immunoassay to research occult bleeding in feaces (with one or two fecal samples).
Performance of the test when used with an optimized positivity thresholdAt baselineSensitivity, specificity and likelihood ratios of the immunological testing will be calculated statistically, when an optimized positivity threshold for the population under study is used, as a function of weights (defined by experts consensus) allocated to errors (false negative and false positive cases).

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026