Skip to content

IRIS Ultimaster Cohort in the IRIS-DES Registry

Evaluation of Effectiveness and Safety of Ultimaster® Stent in Routine Clinical Practice; A Multicenter, Prospective Observational Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02719106
Acronym
IRISUltimaster
Enrollment
1000
Registered
2016-03-25
Start date
2016-07-20
Completion date
2024-08-08
Last updated
2025-12-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Keywords

real world data, percutaneous coronary intervention, drug eluting stent

Brief summary

The purpose of this study is to evaluate the relative effectiveness and safety of Ultimaster stent compared to other drug eluting stents.

Interventions

Sponsors

CardioVascular Research Foundation, Korea
CollaboratorOTHER
Duk-Woo Park, MD
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
19 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age 19 and more * Intervention with Ultimaster stent * Agreed with written informed consent form

Exclusion criteria

* Intervention with Ultimaster stent and other drug eluting stent at the same time * Life expectancy of 1year and under * Cardiac shock

Design outcomes

Primary

MeasureTime frameDescription
Composite event1yearThe number of events with the first occurrence of a composite event(death, non-fatal myocardial infarction, target vessel revascularization)

Secondary

MeasureTime frameDescription
Cardiac death5years
Myocardial infarction5years
Composite event of death or myocardial infarction5years
Composite event of cardiac death or myocardial infarction5years
All death5years
Target Lesion revascularization5yearsDefined as any repeat percutaneous intervention of the target lesion or bypass surgery of the target vessel performed for restenosis or other complication of the target lesion. All TLRs should be classified prospectively as clinically indicated or not clinically indicated by the investigator prior to repeat angiography. An independent angiographic core laboratory should verify that the severity of percent diameter stenosis meets requirements for clinical indication and will overrule in cases where investigator reports are not in agreement. The target lesion is defined as the treated segment from 5 mm proximal to the stent and to 5 mm distal to the stent.
Stent thrombosis5yearsDEFINITE stent thrombosis : acute coronary syndrome and angiographic or pathologic evidence of stent thrombosis; PROBABLE stent thrombosis : unexplained death within 30 days or target-vessel infarction without angiographic information Academic Research Consortium (ARC) stent thrombosis is reported as a cumulative value at different time points and within the different separate time points. Time 0 is the time point after the guide catheter has been removed. Acute stent thrombosis: 0-24 hours after stent implantation; Subacute stent thrombosis: \>24 hours to 30 days post; late stent thrombosis: \>30 days to 1 year post; Very late stent thrombosis: \>1 year post;
Stroke5years
Procedural success3daysDefined as mean lesion diameter stenosis ≤50% and without the occurrence of in-hospital myocardial infarction (MI), target vessel revascularization (TVR), or death
Target Vessel revascularization5yearsDefined as any repeat percutaneous intervention or surgical bypass of any segment of the target vessel. The target vessel is defined as the entire major coronary vessel proximal and distal to the target lesion, which includes upstream and downstream branches and the target lesion itself. Clinical-driven Clinically indicated angiography at follow-up shows a percent diameter stenosis ≥ 50% (core lab QCA assessment) and if one of the following occurs: (1) a positive history of recurrent angina pectoris, presumably related to the target vessel; (2) objective signs of ischemia at rest (ECG changes) of during exercise test (or equivalent), presumably related to the target vessel; (3) abnormal results of any invasive functional diagnostic test (eg, Doppler flow velocity reserve, fractional flow reserve). Ischemia-driven if one of followings of above-mentioned symptom (clinical-driven) or sign of ischemia or diameter stenosis ≥ 70 %

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026