Skip to content

Comparison of Two Gingival Displacement Procedures

Comparison of Two Gingival Displacement Procedures; a Randomized Clinical Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02716727
Enrollment
16
Registered
2016-03-23
Start date
2016-10-31
Completion date
2019-11-30
Last updated
2020-08-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Gingival Retraction Techniques

Brief summary

Purpose: To compare the quality of impressions made with a cordless gingival displacement procedure versus impressions made with a corded technique. The devices and materials used in both procedures are FDA-approved, marketed, and will be used according to label. Participants: Approximately sixty (60) adult patients who are treatment planned for indirect restorations (crowns) at the UNC School of Dentistry. Procedures (methods): Participants will be randomized to receive either the cordless gingival displacement procedure (Aquasil Ultra Cordless, Dentsply), or the corded technique (Ultrapak, Intradent) followed by impression with Aquasil Ultra, Dentsply. Participants will complete the Faces pain scale. Impressions will be photographed, digitally scanned, and evaluated.

Detailed description

Background: Indirect fixed prosthodontic restorations are widely used for the restoration of teeth. The fabrication of a well-fitting indirect restoration requires an accurate impression which captures the cervical finish line. Dentists have a hard time making proper impressions, with a reported 56% of impressions sent to labs being inadequate. The most common deficiency is inadequate recording of the cervical finish line. The primary reason for this inadequacy is deficient gingival displacement technique. More effective and efficient gingival displacement procedure can lead to clinically improved fixed restorations, less patient chair time, and less patient discomfort. Materials and Methods: Sixty (60) patients will be recruited from the University of North Carolina (UNC) School of Dentistry (SOD), and they will be randomly split into 2 equal sized groups: 30 patients cordless gingival displacement procedure (Aquasil Ultra Cordless, Dentsply International); 30 patients traditional corded technique using Aquasil Ultra Polyvinyl siloxane (PVS) impression material, Dentsply International, gingival displacement cord (Ultrapak, Ultradent Products International) hydrated with aluminum chloride hexahydrate (Hemodent, Premier Dental Products Company). Patient inclusion criteria include: 1) requires indirect restoration/s. 2) probing depths 4mm or less. 3) No bleeding on probing. 4) finish line 0-1mm sub-gingival. Specific Aims: 1. To examine if a cordless gingival displacement procedure can properly displace gingival tissue to facilitate acceptable impressions that accurately capture the prepared cervical finish line for the fabrication of indirect fixed prosthodontic restorations. These impressions will be digitally scanned, and then all of the impression scans will be evaluated for acceptability based on a set of criteria (evaluation form). The evaluations will be conducted by 2 standardized individuals. 2. To determine if a cordless gingival displacement procedure facilitates impressions that area at least as good as the traditional corded gingival displacement procedure. The impression scans will be evaluated and then a comparison will be made between the 2 groups of impressions. 3. To determine if a cordless gingival displacement procedure is more time efficient than the traditional corded procedure. All procedures will be timed, starting when the gingival displacement procedure is commenced and ending when the impression is removed from the patient's mouth. 4. To determine if a cordless gingival displacement procedure causes less trauma and discomfort to the patient than the traditional corded procedure. Patient discomfort will be evaluated with a 3 question written survey (0-10 scale answers). The hypothesis contemplated in this proposal explores if a cordless gingival displacement procedure can properly displace gingival tissues to facilitate an acceptable impression that accurately captures the prepared cervical finish line for the fabrication of indirect fixed prosthodontic restorations. Our objective is to identify if a new procedure can improve the efficiency of a traditionally technique-sensitive procedure in dentistry. Materials and Methods: A total of sixty participants will be recruited from the University of North Carolina (UNC) School of Dentistry (SOD) Graduate Prosthodontics clinic, Graduate Operative clinic, and the Dental Faculty Practice. There will be two (2) randomly assigned groups; thirty (30) patients who will receive a cordless gingival displacement procedure (Aquasil Ultra Cordless, Dentsply International) and thirty (30) patients who will receive the traditional gingival displacement technique with retraction cord (UltraPak, Ultradent Products International) hydrated with aluminum chloride hexahydrate (Hemodent, Premier Dental Products Company), and impression made with Polyvinyl siloxane (PVS) impression material (Aquasil Ultra, Dentsply International). Any indirect restoration requires an accurate impression of the prepared margins and the tooth. To obtain an accurate impression, the gingiva has to be displaced or retracted temporarily to allow for the impression material to flow into the gingival sulcus and capture the margins of the preparation. Traditionally this is accomplished by packing two knitted cords. The cordless technique does not require this step but uses a pneumatic hand piece through which the light body impression material is injected in the sulcus displacing the gingival tissue in order to capture the margins of the prepared tooth. Both techniques are described in detail below. Traditional Corded Impression Procedure: 1. The prepared tooth is rinsed and dried, and assure hemostasis. 2. Small diameter retraction cord, after it has been hydrated with Hemodent (hemostatic agent) for 10 minutes, is tucked around the tooth in the space between it and its surrounding gum tissue. A second larger diameter retraction cord, also hydrated with Hemodent, will be placed over the first cord and tucked around the tooth. These cords will be left in place for a minimum of 8 minutes. These cords temporarily push the gum tissue away from the tooth. 3. After a minimum of 8 minutes, the larger 2nd cord will be removed, and the tooth dried. Quickly, after confirmation of a dry field, the light body consistence impression material is dispensed using a plastic syringe around the prepared tooth and across the occlusal surfaces of adjacent teeth. 4. An impression tray that has been filled with the heavy body consistency impression material is then placed over the arch of teeth, and gently pressed into place to ensure the teeth are completely covered with a uniform thickness of impression material. As the different impression material consistencies set, they fuse together into a single unit. 5. When removed from the mouth, the impression should contain a negative copy of both the prepared tooth and the teeth of that jaw. Cordless Impression Procedure: 1. The prepared tooth is rinsed and dried, and assure hemostasis. 2. Apply B4 + surface optimizer (manufacturer recommended for increasing the wettability of the prepared tooth). 3. Using the digit power dispenser (pneumatic hand piece that connects to the dental chair), unit dose cartridge, and intrasulcular plastic mixing tip, depress foot pedal and gently insert the plastic tip into the gingival sulcus of the prepared tooth, slightly apical to the preparation finish line. Material should flow into the gingival sulcus making sure to have impression material ahead of the intrasulcular tip as you move around the tooth and the prepared finish line. 4. An impression tray that has been filled with the heavy body consistency impression material is then placed over the arch of teeth, and gently pressed into place to ensure the teeth are completely covered with a uniform thickness of impression material. As the different impression material consistencies set, they fuse together into a single unit. 5. When removed from the mouth, the impression should contain a negative copy of both the prepared tooth and the teeth of that jaw. Post Impression: Once the impressions are made, the clinician will record the type of impression material used; whether tray adhesive was used; the tray material; the type of tray used; and the number of units requested. The impressions will be photographed and digitally scanned and then collectively evaluated at a later time, based on a criteria evaluation form by two calibrated evaluators. The evaluator will assess each impression for errors in the finish line; in the tray/material; and errors with gingival displacement/hemostasis as primary outcomes. The number of errors can range from 0 to 13. Two secondary outcomes will also be analyzed. First, the time required to perform the impression procedure will be recorded using a timer. Second, patient discomfort will be assessed using the FACES visual picture pain scale rated from 1-10 based on the following question posed at 3 points during treatment; How much discomfort are you experiencing at this point in treatment? This question will be asked before the impression procedure is initiated, immediately after the impression procedure is completed, and again at the completion of the treatment appointment. Each question will be rated on a scale of 1 to 10. The total score indicated by the sum of the 3 questions will be analyzed. As part of this study, the participant might be seen one or two times, one for consenting to participate in the study and another time for treatment and impression; we may be able to complete both during the same appointment. The consent appointment will ideally occur simultaneously with their consultation/treatment planning appointment prior to treatment. The proposed research study will approximately include a total of 60 participants. Recruitment of the patient population will rely on referrals from UNC School of Dentistry (UNC SOD) Faculty Practice, UNC SOD dental student's clinic (DDS student clinics, graduate student clinics and DFP). Apart from participating in the study, the patient may seek other dental treatments in the above mentioned clinics. Study clinicians will be calibrated on both the cordless and the corded gingival displacement procedures and impression procedures in a practice session. Clinical instruction protocols will be printed on laminated forms for all study clinicians to follow, for both the cordless and the corded procedures. These clinical protocol forms will be in the clinicians operatory during actual study treatment, and this protocol must be followed for the impression to be included in the study. On the day of the appointment, participants will be requested to sign a consent form. The study subject will be asked to complete the standard adult medical and dental health history questionnaire provided by the UNC SOD and will be provided with the UNC Chapel Hill Notice of Privacy Practices and the Consent for Purposes of Treatment, payment and health care operation. Other than the screening consent, these are standard practices followed by UNC SOD for all patients. The study is mandated to adhere to theses protocols prior to treating a patient at the UNC SOD. An oral examination will be performed by the research dentist to evaluate if the patient meets inclusion criteria, after the subject has signed all documents. Upon consent to participate, appointments will be made for treatment at UNC SOD, as it would happen as part of their regular treatment. Second appointment - during this scheduled time, a clinical re-evaluation will be completed, and if appropriate, treatment will be completed. Clinical data will be collected prior to starting the treatment; we will collect soft tissue response \[Bleeding on Probing (BoP) and Probing Pocket Depth (PPD)\]. Customary anesthesia and tooth preparation will be performed by the clinician as necessary for the particular indirect restoration, and when completed, the finish line will be evaluated for inclusion criteria by the clinician. If all inclusion criteria are met, a coin toss will determine which gingival displacement procedure will be performed, and the gingival displacement procedure and impression will be made as described in this study protocol and as followed on the laminated clinical protocol sheet. If the clinician finds that the first impression is inadequate and chooses to make an additional impression, only the first impression will be evaluated for the study and a note will be indicated to record the number of impressions the clinician made to achieve an acceptable impression. If the inclusion criteria are not met, a clinically appropriate impression method will be performed at the clinician's judgment and will be made per case by the treating clinician, following standard of care for the treatment that the patient receives. Patients will be given appropriate verbal and written post-procedure instructions; and appointments will be made for restoration try-in and delivery, as would happen as part of their regular treatment. There are no potential direct benefits to the participant besides the fact that particularly close attention will be paid to the gingival displacement and impression procedures, and there will be close evaluation of impressions. All of the impressions will be photographed and digitally scanned, and also given a number which will be recorded on a master sheet with the type of gingival displacement procedure indicated. No other patient identifiers will be included. These scans will be evaluated collectively on a later day, and will be critiqued based on a criteria form. This evaluation will be performed by 2 investigators, and will be completed independently. Impressions will be deemed acceptable or not acceptable, and the reasons for not acceptable impressions will be indicated. The evaluation criteria are listed in Appendix B. The scientific knowledge to be gained will be the efficacy of a new gingival displacement procedure, and if it can be adopted to improve patient treatment and treatment outcomes. The risks of the study are consistent with the current standard of care. Standard treatment protocols will be observed for the treatment of teeth which require indirect restorations. The risks will be minimized by treatment evaluation and proper treatment technique. Data monitoring Research data management will involve collection, entry, processing, storage, retrieval, archival, distribution and documentation of information. Data collection will adhere to precise written forms. Data will be stored in a series of Microsoft Access data files, which will be accessible to the Investigators and their staff. Only project-related personnel will be able to access these files. Data collection forms will be kept in locked files. Quality assurance (QA) will occur as data is entered in order to check for data completeness and consistency prior to entry.

Interventions

DEVICEAquasil Ultra Cordless, Dentsply

Cordless gingival displacement procedure

DEVICEUltrapak, Ultradent cord

Cordless gingival displacement procedure

Sponsors

University of North Carolina, Chapel Hill
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Patients must be adult males or females over the age of 18. * Patients must be able and willing to follow study procedures and instructions. * Patients must have read, understood and signed an informed consent form. * Patients must be in good general health. * Patient must require one or more indirect restorations. * Probing pocket depths around the treatment tooth/teeth must be 4mm or less. * There must be no bleeding on probing around the treatment tooth/teeth. * The prepared finish line must be between 0 to 1mm sub-gingival (inclusive).

Exclusion criteria

* Individuals who have a chronic disease with oral manifestations. * Individuals who exhibit gross oral pathology. * Smokers, Diabetics

Design outcomes

Primary

MeasureTime frameDescription
Percentage of Errors in Impressions Made for Indirect RestorationsThrough impression completion, an average of 10-20 minutes or when impression material is completely setImpressions will be assessed for technique errors
Mean Time Required to Make the ImpressionThrough impression completion, an average of 10-20 minutes or when impression material is completely setThe time required to perform the impression procedures from the start of the gingival displacement procedure to completion of impression.
Mean Patient Discomfort ScoresFrom start of visit until the end of the visit, approximately 3 hoursPatient discomfort will be assessed using the Wong-Baker FACES Pain Rating Scale™.The FACES Pain Scale is a dimensionless 10-point Likert scale used to assess self-reported pain intensity on a scale from 0 (no pain) to 10 (most pain you can imagine). Greater pain scores are indicative of more severe pain. Patients self-reported pain using the FACES evaluation at the beginning of the appointment, immediately before start of impression procedure, immediately after the impression procedure completed, and at the end of the appointment.

Secondary

MeasureTime frameDescription
Comparison of Percentage of Impression Errors Based on Maxillary and Mandibular ArchThrough impression completion, an average of 10-20 minutes or when impression material is completely setAccuracy of the impression assessed for technique errors based on the location of the tooth in the mouth (maxillary and mandibular arch).
Comparison of Percentage of Impression Errors Made by Residents and FacultyThrough impression completion, an average of 10-20 minutes or when impression material is completely setAccuracy of the impression assessed for technique errors based on the clinical experience of the provider.
Mean Patient Discomfort Score Comparison Based on Maxillary and Mandibular ArchThrough impression completion,an average of 10-20 minutes or when impression material is completely setPatient discomfort will be assessed based on the location of the tooth in the mouth (maxillary and mandibular arch) using the Wong-Baker FACES Pain Rating Scale™.The FACES Pain Scale is a dimensionless 10-point Likert scale used to assess self-reported pain intensity on a scale from 0 (no pain) to 10 (most pain you can imagine). Greater pain scores are indicative of more severe pain. Patients self-reported pain using the FACES evaluation at the beginning of the appointment, immediately before start of impression procedure, immediately after the impression procedure completed, and at the end of the appointment.
Comparison of the Time Required to Make Impressions in the Maxillary and Mandibular ArchThrough impression completion, an average of 10-20 minutes or when impression material is completely setThe time required to perform the impression procedures from the start of the gingival displacement procedure to completion of impression based on the location of the tooth in the mouth (maxillary and mandibular arch).
Comparison of the Time Required to Make Impressions Between Residents and FacultyThrough impression completion, an average of 10-20 minutes or when impression material is completely setThe time required to perform the impression procedures from the start of the gingival displacement procedure to completion of impression based on the clinical experience of the provider.
Mean Patient Discomfort Score Comparison for Procedures Completed by Residents and FacultyFrom start of visit until the end of the visit, approximately 3 hoursPatient discomfort will be assessed based on the clinical experience of the provider using the Wong-Baker FACES Pain Rating Scale™.The FACES Pain Scale is a dimensionless 10-point Likert scale used to assess self-reported pain intensity on a scale from 0 (no pain) to 10 (most pain you can imagine). Greater pain scores are indicative of more severe pain. Patients self-reported pain using the FACES evaluation at the beginning of the appointment, immediately before start of impression procedure, immediately after the impression procedure completed, and at the end of the appointment.

Countries

United States

Participant flow

Participants by arm

ArmCount
Aquasil Ultra Cordless, Dentsply
Gingival displacement procedure that uses a pneumatic hand piece to inject the light body impression material into the gingival sulcus. Aquasil Ultra Cordless, Dentsply: Cordless gingival displacement procedure
7
Ultrapak, Ultradent Cord
The knitted cord is used for physical displacement of gingival tissue. Cord is placed in the gingival sulcus and left in place for at least 4 minutes to achieve gingival displacement. Ultrapak, Ultradent cord: Cordless gingival displacement procedure
9
Total16

Baseline characteristics

CharacteristicUltrapak, Ultradent CordTotalAquasil Ultra Cordless, Dentsply
Age, Continuous65.0 years
STANDARD_DEVIATION 9.03
60.5 years
STANDARD_DEVIATION 4.2
56.2 years
STANDARD_DEVIATION 15.01
Race and Ethnicity Not Collected0 Participants
Region of Enrollment
United States
9 Participants16 Participants7 Participants
Sex: Female, Male
Female
6 Participants8 Participants2 Participants
Sex: Female, Male
Male
3 Participants8 Participants5 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 70 / 9
other
Total, other adverse events
0 / 70 / 9
serious
Total, serious adverse events
0 / 70 / 9

Outcome results

Primary

Mean Patient Discomfort Scores

Patient discomfort will be assessed using the Wong-Baker FACES Pain Rating Scale™.The FACES Pain Scale is a dimensionless 10-point Likert scale used to assess self-reported pain intensity on a scale from 0 (no pain) to 10 (most pain you can imagine). Greater pain scores are indicative of more severe pain. Patients self-reported pain using the FACES evaluation at the beginning of the appointment, immediately before start of impression procedure, immediately after the impression procedure completed, and at the end of the appointment.

Time frame: From start of visit until the end of the visit, approximately 3 hours

ArmMeasureGroupValue (MEAN)Dispersion
Aquasil Ultra Cordless, DentsplyMean Patient Discomfort ScoresStart of Visit7.64 score on a scaleStandard Deviation 6.03
Aquasil Ultra Cordless, DentsplyMean Patient Discomfort ScoresImmediately Before Starting Impression8.64 score on a scaleStandard Deviation 7.87
Aquasil Ultra Cordless, DentsplyMean Patient Discomfort ScoresImmediately After Impression Completed1.85 score on a scaleStandard Deviation 1.57
Aquasil Ultra Cordless, DentsplyMean Patient Discomfort ScoresAt End of Visit8.00 score on a scaleStandard Deviation 7.58
Ultrapak, Ultradent CordMean Patient Discomfort ScoresAt End of Visit8.00 score on a scaleStandard Deviation 7.58
Ultrapak, Ultradent CordMean Patient Discomfort ScoresStart of Visit8.31 score on a scaleStandard Deviation 6.03
Ultrapak, Ultradent CordMean Patient Discomfort ScoresImmediately After Impression Completed2.12 score on a scaleStandard Deviation 1.45
Ultrapak, Ultradent CordMean Patient Discomfort ScoresImmediately Before Starting Impression7.43 score on a scaleStandard Deviation 7.87
Primary

Mean Time Required to Make the Impression

The time required to perform the impression procedures from the start of the gingival displacement procedure to completion of impression.

Time frame: Through impression completion, an average of 10-20 minutes or when impression material is completely set

ArmMeasureValue (MEAN)Dispersion
Aquasil Ultra Cordless, DentsplyMean Time Required to Make the Impression5.92 minutesStandard Deviation 8.57
Ultrapak, Ultradent CordMean Time Required to Make the Impression9.81 minutesStandard Deviation 8.57
Primary

Percentage of Errors in Impressions Made for Indirect Restorations

Impressions will be assessed for technique errors

Time frame: Through impression completion, an average of 10-20 minutes or when impression material is completely set

ArmMeasureGroupValue (NUMBER)
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsVoid on Preparation85.7 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsRetraction Cord Attached0 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsBlood on the Impression0 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsVoids/Bubbles85.7 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsLack of Wash Material28.6 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsTearing71.4 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsCotton Roll Attached0 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsInadequate Fusion Between Wash & Tray Material57.1 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsLack of Polymerization14.3 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsInadequate Retention0 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsPressure of Tray on Soft Tissue0 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsShow-through of Occlusal/Incisal Edges0 percentage of impressions
Aquasil Ultra Cordless, DentsplyPercentage of Errors in Impressions Made for Indirect RestorationsTissue Over Finish Line42.9 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsPressure of Tray on Soft Tissue11.1 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsInadequate Fusion Between Wash & Tray Material11.1 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsRetraction Cord Attached11.1 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsVoid on Preparation88.8 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsBlood on the Impression33.3 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsLack of Polymerization0 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsVoids/Bubbles33.3 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsTissue Over Finish Line11.1 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsLack of Wash Material44.4 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsInadequate Retention0 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsTearing11.1 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsShow-through of Occlusal/Incisal Edges22.2 percentage of impressions
Ultrapak, Ultradent CordPercentage of Errors in Impressions Made for Indirect RestorationsCotton Roll Attached11.1 percentage of impressions
Secondary

Comparison of Percentage of Impression Errors Based on Maxillary and Mandibular Arch

Accuracy of the impression assessed for technique errors based on the location of the tooth in the mouth (maxillary and mandibular arch).

Time frame: Through impression completion, an average of 10-20 minutes or when impression material is completely set

Population: Due to loss of key study personnel these data were not collected.

Secondary

Comparison of Percentage of Impression Errors Made by Residents and Faculty

Accuracy of the impression assessed for technique errors based on the clinical experience of the provider.

Time frame: Through impression completion, an average of 10-20 minutes or when impression material is completely set

Population: Due to loss of key study personnel these data were not collected.

Secondary

Comparison of the Time Required to Make Impressions Between Residents and Faculty

The time required to perform the impression procedures from the start of the gingival displacement procedure to completion of impression based on the clinical experience of the provider.

Time frame: Through impression completion, an average of 10-20 minutes or when impression material is completely set

Population: Due to loss of key study personnel these data were not collected.

Secondary

Comparison of the Time Required to Make Impressions in the Maxillary and Mandibular Arch

The time required to perform the impression procedures from the start of the gingival displacement procedure to completion of impression based on the location of the tooth in the mouth (maxillary and mandibular arch).

Time frame: Through impression completion, an average of 10-20 minutes or when impression material is completely set

Population: Due to loss of key study personnel these data were not collected.

Secondary

Mean Patient Discomfort Score Comparison Based on Maxillary and Mandibular Arch

Patient discomfort will be assessed based on the location of the tooth in the mouth (maxillary and mandibular arch) using the Wong-Baker FACES Pain Rating Scale™.The FACES Pain Scale is a dimensionless 10-point Likert scale used to assess self-reported pain intensity on a scale from 0 (no pain) to 10 (most pain you can imagine). Greater pain scores are indicative of more severe pain. Patients self-reported pain using the FACES evaluation at the beginning of the appointment, immediately before start of impression procedure, immediately after the impression procedure completed, and at the end of the appointment.

Time frame: Through impression completion,an average of 10-20 minutes or when impression material is completely set

Population: Due to loss of key study personnel these data were not collected.

Secondary

Mean Patient Discomfort Score Comparison for Procedures Completed by Residents and Faculty

Patient discomfort will be assessed based on the clinical experience of the provider using the Wong-Baker FACES Pain Rating Scale™.The FACES Pain Scale is a dimensionless 10-point Likert scale used to assess self-reported pain intensity on a scale from 0 (no pain) to 10 (most pain you can imagine). Greater pain scores are indicative of more severe pain. Patients self-reported pain using the FACES evaluation at the beginning of the appointment, immediately before start of impression procedure, immediately after the impression procedure completed, and at the end of the appointment.

Time frame: From start of visit until the end of the visit, approximately 3 hours

Population: Due to loss of key study personnel these data were not collected.

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026