Coronary Artery Disease, Coronary Artery Stenosis
Conditions
Keywords
DREAMS 2G, Scaffold, Drug Eluting Absorbable Metal Scaffold, Coronary Artery Disease
Brief summary
BIOSOLVE-III Study is a pre-market, prospective, multi-center trial to assess the acute clinical performance of the DREAMS 2G Drug-Eluting Coronary Scaffold in de novo coronary artery lesions.
Interventions
Implanttaion fo the DREAMS 2G Scaffold
Sponsors
Study design
Eligibility
Inclusion criteria
1. Subject is \> 18 years and \< 80 years of age 2. Written subject informed consent available prior to PCI 3. Subjects with stable or unstable angina pectoris or documented silent ischemia 4. Subject eligible for PCI 5. Subject acceptable candidate for coronary artery bypass surgery 6. Subjects with a maximum of two single lesions in two separate coronary arteries which have to be de novo lesions. 7. Reference vessel diameter between 2.7-3.8 mm by visual estimation, depending on the scaffold size used. 8. Target lesion length by visual estimation, assisted by QCA: \< 21 mm, depending on the scaffold size used. 9. Target lesion stenosis by visual estimation, assisted by QCA \> 50% - \< 100% 10. Eligible for Dual Anti Platelet Therapy (DAPT)
Exclusion criteria
1. Pregnant or breast-feeding females or females who intend to become pregnant during the time of the study 2. Evidence of myocardial infarction within 72 hours prior to index procedure 3. Subjects with a ≥2 fold CK level or in absence of CK a ≥3 fold CKMB level above the upper range limit within 24 hours prior to the procedure 4. Left main coronary artery disease 5. Three-vessel coronary artery disease at time of procedure 6. Thrombus in target vessel 7. Subject is currently participating in another study with an investigational device or an investigational drug and has not reached the primary endpoint yet 8. Planned interventional treatment of any non-target vessel within 30 days post procedure 9. Subjects on dialysis 10. Planned intervention of the target vessel after the index procedure 11. Ostial target lesion (within 5.0 mm of vessel origin) 12. Target lesion involves a side branch \>2.0 mm in diameter 13. Documented left ventricular ejection fraction (LVEF) ≤ 30% 14. Heavily calcified lesion 15. Target lesion is located in or supplied by an arterial or venous bypass graft 16. The target lesion requires treatment with a device other than the pre-dilatation balloon prior to scaffold placement (including but not limited to directional coronary atherectomy, excimer laser, rotational atherectomy, etc.) 17. Unsuccessful pre-dilatation, defined as minimal lumen diameter smaller than the respective crossing profile of DREAMS 2G and angiographic complications (e.g. distal embolization, side branch closure, extensive dissections that can't be covered by a single scaffold), by visual estimation 18. Known allergies to: Acetylsalicylic Acid (ASA), Heparin, contrast medium, Sirolimus, Everolimus or similar drugs (i.e., ABT 578, Biolimus, Tacrolimus), PLLA, Silicon Carbide Magnesium, Yttrium, Neodymium, Zirconium, Gadolinium, Dysprosium, Tantalum 19. Impaired renal function (serum creatinine \> 2.5 mg/dl or 221mmol/l) determined within 72 hours prior to intervention 20. Subject is receiving oral or intravenous immuno-suppressive therapy ( inhaled steroids are not excluded) or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus, but not including diabetes mellitus) 21. Proximal or distal to the target lesion located stenosis that might require future revascularization or impede run off detected during diagnostic angiography 22. Life expectancy less than 1 year, or other co-morbidities (e.g. Sepsis, Apoplexy or TIA within 6 months prior to the study procedure) (Co-morbidities definitions will be left to the discretion of the Study Investigators) 23. Planned surgery or dental surgical procedure within 6 months after index procedure 24. Subject with tortuous vessel that may impair scaffold placement in the region of obstruction or proximal to the lesion 25. In the investigators opinion subjects will not be able to comply with the follow-up Requirements
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Acute performance of the DREAMS 2G | During the hospital stay to a maximum of 7 days post study Procedure | Acute performance of the DREAMS 2G assessed by procedure success. Procedure success is defined as: Procedure Success is defined as achievement of a final diameter stenosis of \<30% by QCA (using any percutaneous method) without the occurrence of death, Q-wave or non-Q-wave MI, or repeat revascularization of the target lesion during the hospital stay |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Scaffold thrombosis rate | 1, 6 12, 24 and 36 months post procedure | — |
| Binary in-scaffold and in-segment restenosis rate | 12-months | — |
| Target Lesion Failure (TLF) | 1, 6 12, 24 and 36 months post procedure | TLF defined as a composite of Cardiac Death, Target Vessel Q-wave or non-Q wave Myocardial Infarction (MI)\*\*, Coronary Artery Bypass Grafting (CABG), clinically driven Target Lesion Revascularization (TLR) |
| In-segment late lumen loss | 12-months | — |
| In-scaffold late lumen loss | 12-months | — |
| % in-scaffold and in-segment diameter stenosis | 12-months | — |
Countries
Belgium, Germany, Netherlands, Switzerland