Skip to content

SD-OCT Multimodal Analysis in GLaucoma

SD-OCT Multimodal Analysis in GLaucoma

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02710916
Acronym
SOMAL
Enrollment
109
Registered
2016-03-17
Start date
2016-02-22
Completion date
2018-12-21
Last updated
2026-05-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Eye Diseases, Glaucoma, Ocular Hypertension

Keywords

Optical Coherence Tomography, Intraocular pressure, Optic Nerve Head, Nerve fiber layer, Bruch Membrane Opening -Minimum Rim Width

Brief summary

Glaucoma is the first cause of irreversible blindness worldwide with more than 60 millions people affected in 2010. It is defined as a neurodegenerative disease characterized by a progressive loss of retinal ganglion cells (RGC), visual field deterioration and optic nerve excavation. Intraocular pressure (IOP) is the most common risk factor. Despite its severity, its impact on quality of life and an existing treatment that can delay visual field damages, there is no recommended strategy to screen the disease. Clinical evaluation of optic nerve head excavation performed either by ophthalmologists or glaucoma specialists is highly inter-observer dependent and limits its accuracy to diagnose glaucoma. Additionally, up to 30 to 40% of nerve fiber layer may be lost before detecting first visual field defects, thus making this tool not accurate enough for screening purposes. Spectral-Domain Optical coherence tomography (SD-OCT) imaging technology allows precise and reproducible measurements of optic nerve head structures and retinal layers mainly related to the speed of acquisition and an axial resolution of 5 microns. New SD-OCT parameters have been developed to improve its diagnostic accuracy for glaucoma disease. The investigators therefore investigate performances of SD-OCT to discriminate glaucoma patients and controls. All subjects will undergo SD-OCT imaging (Spectralis™ OCT, Version 6.3, Heidelberg Engineering, Germany) and other study procedures in one single visit. All examinations performed on the subjects are non-significant risk.

Interventions

DEVICESD-OCT Spectralis

All patients will undergo a complete ophthalmological examination with SD-OCT complete evaluation

Sponsors

University Hospital, Bordeaux
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
40 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

Normal Subjects 1. No history or evidence of retinal pathology or glaucoma 2. Normal Humphrey 24-2 Visual Field (VF) : A mean defect (MD), corrected pattern standard deviation (CPSD) within 95% limits of normal reference, and glaucoma hemifield test (GHT) within normal limits (97%). 3. Intraocular pressure \< 21 mm Hg 4. Open angle (Shaffer's grading system) 5. Normal appearing Optic Nerve Hypoplasia (ONH) and Nerve Fiber Layer (NFL) : intact neuroretinal rim without peripapillary hemorrhages, notches, localized pallor, or NFL defect 6. Symmetric ONH between left and right eyes: Cup-to-Disc Ratio (CDR) difference \< 0.2 in both vertical and horizontal dimensions Inclusion Criteria: Perimetric Glaucoma 1. ONH or NFL defect visible on slit-lamp biomicroscopy defined as one of following: * diffuse or localized thinning of the rim * disc (splinter) hemorrhage * notch in the rim * vertical cup/disc ratio greater than the fellow eye by \> 0.2 2. Consistent glaucomatous pattern on both qualifying Humphrey Swedish Interactive Threshold Algorithm (SITA) 24-2 VF meeting at least one of the following quantitative criteria for abnormality: * PSD outside normal limits (p \< 0.05) * GHT outside normal limits (p \< 0.01) Inclusion Criteria: Pre-Perimetric Glaucoma (PPG) PPG participants must have at least one eye meeting all of the following criteria: 1. ONH or NFL defect visible on slit-lamp biomicroscopy defined as one of following: * diffuse or localized thinning of the rim * disc (splinter) hemorrhage * notch in the rim * well-defined peripapillary NFL bundle defect. * inter-eye vertical CDR asymmetry \> 0.2 2. Baseline VF not meeting the criteria for the PG group. 3. Risk factors for glaucoma, one of following: * Intraocular pressure \> 21 mm Hg * Ethnics * Family history of glaucoma

Exclusion criteria

All Groups 1. Age \< 40 2. Refractive error of \> +6.00 D or \< -6.00 D (SE), +3,00 D for astigmatism 3. Diabetic retinopathy 4. Other diseases that may cause VF loss or optic disc abnormalities 5. Inability to clinically view or photograph the optic discs due to media opacity or poorly dilating pupil 6. Inability to perform reliably on automated VF testing 7. Insufficient quality of Spectralis OCT images (this is not determined until after Spectralis OCT examination, and is an unusual circumstance). Minimum requirements are: * Retina completely included in image frame, * Quality Score ≥ 15 in the stored mean images, 8. Refusal of informed consent

Design outcomes

Primary

MeasureTime frameDescription
Evaluation of Bruch's Membrane Opening Minimum Rim Width1 dayDiagnostic accuracy of SD-OCT to discriminate perimetric, preperimetric glaucoma patients and control patients

Secondary

MeasureTime frame
Evaluation of Retinal Nerve Fiber Layer Thickness1 day

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: May 30, 2026