Skip to content

The Effect of Dopamine on Diabetic Retinopathy

The Effect of Dopamine on Diabetic Retinopathy

Status
Completed
Phases
Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02706977
Acronym
Dopamine DR
Enrollment
60
Registered
2016-03-11
Start date
2016-01-31
Completion date
2019-08-15
Last updated
2019-10-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes

Keywords

Ophthalmology

Brief summary

The purpose of this study is to evaluate the use of electroretinogram (ERG) using a novel handheld system, RETeval, and evaluate contrast sensitivity testing in detecting pre-clinical retinopathy on a tablet device. Investigators also seek to assess if a medication called Sinemet™ CR can improve the electrical functions of the eye in participants with diabetes mellitus. This study will include a total of 45 participants; 30 with diabetes mellitus and 15 age-matched non-diabetic controls. Participants with diabetes mellitus and electroretinogram (ERG) delays will be randomized to a low or high dose Sinemet CR group.

Detailed description

The purpose of this study is to evaluate the use of electroretinogram (ERG) using a novel handheld system, RETeval, and evaluate contrast sensitivity testing in detecting pre-clinical retinopathy on a tablet device. Investigators also seek to assess if a medication called Sinemet™ CR can improve the electrical functions of the eye in participants with diabetes mellitus. This study will include a total of 45 participants; 30 with diabetes mellitus and 15 age-matched non-diabetic controls. Participants with diabetes mellitus and electroretinogram (ERG) delays will be randomized to a low or high dose Sinemet™ CT group. Age-matched controls will not receive Sinemet Ct drug treatment. The study involves four visits over the course of 4 weeks, each visit consisting of 2-3 hours. Visual testing will be performed at 1 day and 2 weeks following treatment. The drug treatment will be halted and testing repeated again after a 2 week wash-out period.

Interventions

DRUGLow Dose Sinemet CR

Sinemet CR (25 mg carbidopa/100 mg levodopa) will be taken by mouth twice daily for two weeks.

DRUGHigh Dose Sinemet CR

Sinemet CR (50 mg carbidopa/200 mg levodopa) will be taken by mouth twice daily for two weeks.

DEVICERETeval Electroretinogram (ERG) Testing

ERG testing consists of sitting in the dark for 15 minutes. During the procedure, participants will have a single-use adhesive sensor strip placed on the skin near the eye. A hand-held device, called the RETeval, will be placed in front of the eye and a series of flashes and flickering lights presented. The light intensity level is typically not uncomfortable. When right eye imaging is complete, the procedure will be repeated on the left eye. Both eyes will be evaluated in less than 5 minutes for most participants. Electroretinogram (ERG) testing will be completed at baseline, day 1, week 2, and week 4.

OTHERContrast Sensitivity Testing

Contrast sensitivity testing consists of looking at a series of moving lines on a tablet device. The lines will change from white to grey to black. Participants will be asked to determine when they can no longer distinguish between the lines. Contrast sensitivity testing will be completed at baseline, day 1, week 2, and week 4.

Participants will be asked to look at an eye chart with letters or symbols that become smaller as they move from top to bottom of the chart. Visual acuity testing will be completed at baseline, day 1, week 2, and week 4.

Sponsors

Emory University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

Participants with Diabetes Mellitus: * Diagnosis of diabetes mellitus type-2 * HbA1c between 8 and 12% Age-Matched Controls: * Non-diabetic

Exclusion criteria

Participants with Diabetes Mellitus: * Currently taking dopamine-enhancing drugs (L-DOPA, bromocriptine) * Currently taking nonselective monoamine oxidase (MAO) inhibitors * Diagnosis of psychosis, Parkinson's disease, restless leg syndrome, major depression, confounding ocular disease (eg. visually significant cataract, glaucoma, macular degeneration, or retinitis pigmentosa) * Pregnancy Age-Matched Controls: * Diabetes diagnosis * Currently taking dopamine-enhancing drugs (L-DOPA, bromocriptine) * Currently taking nonselective monoamine oxidase (MAO) inhibitors * Diagnosis of psychosis, Parkinson's disease, restless leg syndrome, major depression, confounding ocular disease (eg. visually significant cataract, glaucoma, macular degeneration, or retinitis pigmentosa) * Pregnancy

Design outcomes

Primary

MeasureTime frameDescription
Change in Retinal Function assessed by Electroretinogram (ERG) DeviceBaseline, Week 4The RETeval device consists of a hand-held wand with a pupil tracker. A skin electrode placed below the eye or DTL fiber records the response to flash stimuli. The pupil tracker provides feedback to the system so that the flash stimuli can compensate for the pupil size and produce the proper illumination to the retina. RETeval is intended to generate photopic signals and measure and display the electrical response signals generated by the retina and the visual nervous system using flash stimuli.
Change in Contrast Sensitivity assessed by the Contrast Sensitivity Function v1.0 (CSF v1.0) Tablet ApplicationBaseline, Week 4Participants will view the screen monocularly while wearing their normal correction. A drifting grating will be presented at 60 cm for 3, 6, 12 and 18 c/d. Following photopic testing (100 lux), the participant will be dark-adapted and a neutral density filter will be applied to the tablet screen to produce luminance of \ 1 lux.
Change in Contrast Sensitivity assessed by the Sine Wave Grafting Test (CSV-1000E)Baseline, Week 4The CSV-1000E is self-illuminated (85 cd/m2). A drifting grating will be presented at 60 cm for 3, 6, 12 and 18 c/d. The participant will view the chart from 2.5m. The intensity of the CSV-1000 will be reduced to 1 lux with neutral density filters for scotopic testing.
Change in Visual Acuity assessed by the Standard Snellen Static ChartBaseline, Week 4The common Snellen chart is printed with eleven lines of block letters. The first line consists of one very large letter, which may be one of several letters, for example E, H, or N. Subsequent rows have increasing numbers of letters that decrease in size. Participants will cover one eye from 6 metres or 20 feet away, and read aloud the letters of each row, beginning at the top. The smallest row that can be read accurately indicates the visual acuity in that specific eye. The test will be repeated covering the opposite eye.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026