Skip to content

Quantitative Endoscopy of H&N

Comparing GTV Delineation With and Without Spatially Registered Endoscopy

Status
Completed
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02704169
Enrollment
15
Registered
2016-03-09
Start date
2013-07-31
Completion date
2019-08-12
Last updated
2022-10-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Head and Neck Cancer

Keywords

head and neck cancer, H&N cancer

Brief summary

The last decade has seen progressive advances in RT delivery, such as intensity modulated radiation therapy (IMRT)and image-guided radiation therapy (IGRT), which now allow highly precise radiation dose delivery. Together, IMRT and IGRT offer the potential of more selective treatment of the primary tumour and surrounding neck nodes by reducing the dose inflicted on critical organs at risk without compromising tumour dose and. IMRT has been shown to significantly decrease radiation-induced toxicity, and is now considered standard treatment for H&N tumors. With these advances in delivery technology, the accurate definition of the target is emerging as the weakest link in the radiotherapeutic treatment chain. Accurate target definition is the primary link on which all subsequent treatment planning and delivery depend and is therefore critical for successful RT. Incorrect target definition can result in poorer outcomes through either less tumour control, more normal tissue toxicity, or both. Computed x-ray tomography (CT) is the standard volumetric imaging modality for RT because of its high resolution, accurate definition of anatomy and its intrinsic measure of electron density necessary for accurate dose calculation. However, its ability to distinguish between tumour and normal tissue is limited due to a lack of contrast for structures of similar electron density and image artifacts for objects of high density. This additional noise can result in large inter-observation variability. Disease visible on endoscopy can be contoured and registered to the planning CT, allowing inclusion of superficial disease invisible on the volumetric CT image dataset into the treatment plan.

Interventions

OTHERSpatially registered endoscopy

Sponsors

Princess Margaret Hospital, Canada
CollaboratorOTHER
University Health Network, Toronto
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age ≥ 18 years * Histologic diagnosis of squamous cell carcinoma * Primary cancer of the H&N * Intention to treat using external beam radiation therapy as part of standard radiotherapy. * Ability to provide written informed consent to participate in the study

Exclusion criteria

* Prior complete or partial radiation therapy to H&N * Prior complete or partial surgery of the tumour * Contraindications to full dose radiation therapy including pregnancy, lactation, connective tissue disorders, serious co-morbid illness * Concurrent illness or condition that precludes subject from undergoing endoscopy or CT scanning * Psychiatric or addictive disorders that preclude informed consent or adherence to protocol

Design outcomes

Primary

MeasureTime frameDescription
Difference between endoscopic gross tumor volume contours (GTV-endo) and standard gross tumor volume contours (GTV-std)18 monthsDetermine if spatially registered endoscopic gross tumor volume contours (GTV-endo) and standard gross tumor volume contours (GTV-std) are significantly different in primary H&N tumors treated with radiation therapy
Difference between inter-observer variation (V) of endoscopic gross tumor volume and of standard gross tumor volume18 monthsDetermine if the inter-observer variation (V) of spatially registered endoscopic gross tumor volume contours is significantly less than standard gross tumor volume contours in primary H&N tumors treated with radiation therapy

Secondary

MeasureTime frameDescription
Difference between dose distribution using endoscopic gross tumor volume and using standard gross tumor volume18 monthsDetermine if the dose distributions using spatially registered endoscopic GTV contours and standard GTV contours are significantly different in primary H&N tumors treated with radiation therapy with regard to both normal tissue radiation exposure and tumor coverage

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 18, 2026