Measurement of Pulse Pressure Variation and Cardiac Output by a New Application for Android™ (Captesia™)

Measurement of Pulse Pressure Variation (PPV) and Cardiac Output (CO) by a New Application for Android™ (Captesia™) : Comparison With PPV and CO Obtained by a Method of Transpulmonary Thermodilution.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02692222
Enrollment
57
Registered
2016-02-26
Start date
2016-02-29
Completion date
2016-12-31
Last updated
2016-12-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Bypass

Keywords

pulse pressure variation monitoring, Captesia, cardiac output monitoring

Brief summary

This study test the agreement and accuracy of Pulse Pressure Variation (PPV) and Cardiac Output (CO) obtained by the Android application Capstesia™ against the gold standard : PPV and CO calculated by thermodilution.

Detailed description

Pulse pressure variation (PPV) remains a good predictor of fluid responsiveness in the OR. However, PPV can be time-consuming to calculate (manual determination), is not always displayed on monitoring screens nor reliable through visual assessment and needs additional devices to be displayed. A new Android application (Captesia) automatically calculates the PPV utilizing a digital photograph of the arterial waveform from the monitor. The application determines the PPV by selecting peaks and troughs of the arterial curve.

Interventions

OTHERCalculation of PPV and CO with two methods

Sponsors

Erasme University Hospital
Lead SponsorOTHER

Study design

Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* patients scheduled for coronary artery bypass

Exclusion criteria

* patients with arrhythmias like atrial fibrillation * patients with valvular insufficiency

Design outcomes

Primary

MeasureTime frameDescription
PPVat time of surgerythe Pulse Pressure Variation will be calculated by the Android Application (Captesia) and by the Picco before and after a meneuver of volume expansion, which goal is to change the cardiac output.

Secondary

MeasureTime frameDescription
COat time of surgerythe Cardiac Output will be calculated by the Android Application (Captesia) and by thermodilution before and after of volume expansion, which goal is to change the cardiac output.