Breast Cancer
Conditions
Keywords
Mammography
Brief summary
The purpose of this pilot is to assess the adequacy of the Fujifilm DBT Reader Study Training program to ensure that Readers participating in the Fujifilm DBT pivotal trial are properly trained in the reading and interpretation of FFDM and DBT images.
Detailed description
For this reader study, radiologists review images obtained via protocol FMSU2013-004A. They review both FFDM alone and FFDM + DBT images, and provide a BI-RADS and POM for each. The radiologists performance metrics for the following modalities will be evaluated: FFDM and FFDM + DBT.
Interventions
FujiFilm Aspire Cristalle System
FujiFilm Aspire Cristalle System
Sponsors
Study design
Eligibility
Inclusion criteria
* Female subjects participating in FMSU004A protocol with known clinical status
Exclusion criteria
* Subjects with unknown clinical status not participating in FMSU004A protocol.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Assessing Adequacy of Training - Cancer Detection Threshold & Recall Rate | 4 weeks | This endpoint was evaluated qualitatively. Reported the number of readers meeting the Pass Criteria on the final FFDM plus DBT assessment case set, which requires adequate performance in cancer cases (detection rate) as well as non-cancer cases (recall rate). Per-subject BI-RADS, POM and recall scores were derived. Credit was only given for identifying a subject with cancer if the reader marked findings in at least one location with cancer. Findings that did not match the location of a malignant lesion were ignored for cancer cases in the per-subject analyses. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Area Under Curve (AUC) ROC (Receiver Operating Characteristic) Based on Per-subject Probability of Malignancy (POM) Scores Requiring Correct Lesion Localization. | 5 weeks | The magnitude and direction of differences between performance metrics for the two modalities, and variance components and correlations that would influence sample size and case mix for the pivotal reader study (FMSU2013-004G) comparing performance metrics between the two modalities, obtained using established methods for analysis of MRMC (multi-reader, multi-case) studies. The statistician estimated AUC's for each reader in each review condition based on per-subject POM scores requiring correct lesion localization. Statistician performed MRMC comparison of AUC's between reading conditions using the MRMC analysis of variance (ANOVA) method. |
Countries
United States
Participant flow
Recruitment details
The 100 breast screening and diagnostic cases selected for this study, were obtained from the FMSU2013-004A acquisition study. The statistician randomly selected cases to provide a distribution of density, finding types, etc.
Pre-assignment details
Each radiologist read all 100 cases as FFDM only and FFDM+DBT(100 cases multiplied by 2 modalities = 200 reads) with a 4 week washout period between the 2 sessions.
Participants by arm
| Arm | Count |
|---|---|
| All 100 Cases/Study Participants Each case contributed 2 sets of images: FFDM only as well as DBT plus FFDM. Therefore there were 200 reads acquired from the 100 cases/participants. | 100 |
| Total | 100 |
Baseline characteristics
| Characteristic | All 100 Cases/Study Participants |
|---|---|
| Age, Continuous | 58 years STANDARD_DEVIATION 10.3 |
| Race (NIH/OMB) American Indian or Alaska Native | 0 Participants |
| Race (NIH/OMB) Asian | 3 Participants |
| Race (NIH/OMB) Black or African American | 8 Participants |
| Race (NIH/OMB) More than one race | 0 Participants |
| Race (NIH/OMB) Native Hawaiian or Other Pacific Islander | 0 Participants |
| Race (NIH/OMB) Unknown or Not Reported | 2 Participants |
| Race (NIH/OMB) White | 87 Participants |
| Region of Enrollment United States | 100 participants |
| Sex: Female, Male Female | 100 Participants |
| Sex: Female, Male Male | 0 Participants |
Adverse events
| Event type | EG000 affected / at risk | EG001 affected / at risk |
|---|---|---|
| deaths Total, all-cause mortality | 0 / 100 | 0 / 100 |
| other Total, other adverse events | 0 / 100 | 0 / 100 |
| serious Total, serious adverse events | 0 / 100 | 0 / 100 |
Outcome results
Assessing Adequacy of Training - Cancer Detection Threshold & Recall Rate
This endpoint was evaluated qualitatively. Reported the number of readers meeting the Pass Criteria on the final FFDM plus DBT assessment case set, which requires adequate performance in cancer cases (detection rate) as well as non-cancer cases (recall rate). Per-subject BI-RADS, POM and recall scores were derived. Credit was only given for identifying a subject with cancer if the reader marked findings in at least one location with cancer. Findings that did not match the location of a malignant lesion were ignored for cancer cases in the per-subject analyses.
Time frame: 4 weeks
Population: The study employed a fully factorial, counterbalanced crossover design in which all readers reviewed images from all cases in two visits separated by a memory washout period of approximately 4 weeks. Each reader read half FFDM cases and half FFDM + DBT cases during each of 2 visits.
| Arm | Measure | Value (MEAN) |
|---|---|---|
| FFDM Plus DBT | Assessing Adequacy of Training - Cancer Detection Threshold & Recall Rate | .805 probability |
| Full-Field Digital Mammography (FFDM) | Assessing Adequacy of Training - Cancer Detection Threshold & Recall Rate | 0.756 probability |
Area Under Curve (AUC) ROC (Receiver Operating Characteristic) Based on Per-subject Probability of Malignancy (POM) Scores Requiring Correct Lesion Localization.
The magnitude and direction of differences between performance metrics for the two modalities, and variance components and correlations that would influence sample size and case mix for the pivotal reader study (FMSU2013-004G) comparing performance metrics between the two modalities, obtained using established methods for analysis of MRMC (multi-reader, multi-case) studies. The statistician estimated AUC's for each reader in each review condition based on per-subject POM scores requiring correct lesion localization. Statistician performed MRMC comparison of AUC's between reading conditions using the MRMC analysis of variance (ANOVA) method.
Time frame: 5 weeks
| Arm | Measure | Value (MEAN) |
|---|---|---|
| FFDM Plus DBT | Area Under Curve (AUC) ROC (Receiver Operating Characteristic) Based on Per-subject Probability of Malignancy (POM) Scores Requiring Correct Lesion Localization. | 0.805 Probability |
| Full-Field Digital Mammography (FFDM) | Area Under Curve (AUC) ROC (Receiver Operating Characteristic) Based on Per-subject Probability of Malignancy (POM) Scores Requiring Correct Lesion Localization. | 0.777 Probability |