Skip to content

Vascular Post Market Review

Vascular Post Market Review

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02681341
Enrollment
10
Registered
2016-02-12
Start date
2016-02-29
Completion date
2017-09-21
Last updated
2017-10-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Carotid Endarterectomy

Brief summary

The primary objective of this study is to confirm that properties of CardioCel provide operative benefit to surgeons when compared to Dacron, CorMatrix, and all other bovine pericardium not treated with proprietary ADAPT engineering.

Detailed description

ENDPOINTS 1. OR experience: suturability, handling, hemostasis, compliance to recipient vessel, blood loss, OR time. 2. In-hospital survival 3. MAE (Stroke, MI, death) 4. 1 Month duplex US scan 5. 6 month duplex US scan Secondary Efficacy Endpoints 1\. Less than 50% stenosis at 6 months (PSV \<150 cm/s) Safety Endpoint Incidence of CardioCel related Major Adverse Cardiac Events (MACE) at 6 months, defined for this study as: * Structural CardioCel failure - aneurysm/dilation * Vasculitis * Leak or pseudoaneurysm * Dehiscence * Thromboembolism * Thrombosis * Haemolysis * Reoperation and explant Review endpoints at 6 months to confirm results meet the expectations of the Principal Investigator. BACKGROUND Rationale for Study: CardioCel's unique strength, pliability, resistance to degradation and calcification make it a promising alternative to synthetic fabrics or other xenographic materials incompletely decellularized or detoxified (aldehyde removal). Device Description: Tissue-engineered CardioCel pericardium is manufactured from bovine spongiform encephalopathy-free pericardium (37). Manufacturing consists of several tissue-engineering processes, which include steps to remove lipids, cells and cell remnants, nucleic acids (DNA, RNA) and Gal epitopes. In addition, cross-linking is achieved with an ultra-low engineered glutaraldehyde concentration to minimise glutaraldehyde cytotoxicity levels (Admedus Ltd. proprietary). Cytotoxicity is further reduced by the ADAPT® anti-calcification process and a non-glutaraldehyde sterilisation and storage solution. CardioCel is US FDA cleared for the repair of cardiac and vascular defects, including intra-cardiac defects; septal defects, valve and annulus repair, great vessel reconstruction, peripheral vascular reconstruction, suture line buttressing and pericardial closure. STUDY DESIGN This is a prospective, non-randomized, single arm study. SCHEDULE OF ASSESSMENTS/DATA COLLECTION ENROLLMENT: 10 subjects to be enrolled per site DURATION OF ENROLLMENT: Patients will be followed for 6 months after CEA procedure. SCREENING A pre-screening procedure may be performed to determine whether the patient meets the inclusion/exclusion eligibility selection criteria. A pre-screened patient will be asked to sign the informed consent form before any study-specific tests or procedures are performed. Subject screening numbers will be assigned at this visit and subjects will be evaluated for eligibility criteria. BASELINE Informed consent will be obtained from all subjects who are potential trial candidates prior to commencement of any study related procedures. The following baseline data will be collected for all subjects prior to procedure: * Patient demographics * Standard of care Physical Examination * Vital Signs (Blood pressure and heart rate only) * Medical history (for cardiovascular risk factors) * Standard of care Clinical Lab tests * Final confirmation of Inclusion/Exclusion Criteria IMPLANT PROCEDURE Patients will undergo a CEA with patch arterioplasty. Patients will be managed according to standard pre-operative, operative, and postoperative care. The following OR Experience data will be collected for all subjects: * Suturability * Handling * Hemostasis * Compliance to recipient vessel * Blood loss * OR time * In-hospital survival * MAE (Stroke, MI, death) FOLLOW-UP VISITS Patients will return for follow-up visits that will include a carotid duplex ultrasound at 1 and 6 months. Follow-up visits may also include a physical examination and adverse event review. The following follow-up data will be collected for all subjects: * Standard of care physical examination * 1 Month duplex US scan- Duplex US scanning for velocity, calibre, occlusion/lesion status * 6 month duplex US scan- Duplex US scanning for velocity, calibre, occlusion/lesion status * MAE (Stroke, MI, death) and AE review at each visit STATISTICAL ANALYSIS & DATA MANAGEMENT: Principal Investigator plans to follow patients for 6 months and create report (white paper) on OR experiences and 6 month follow-up. The study is a direct observation of 6 month follow-up for patients undergoing CEA with patch arterioplasty. No control group is included in the study, and no comparative analysis is planned. DATA MONITORING Internal monitoring will be conducted periodically. CRF's, source documents, informed consent forms, and study deviations will be included; these findings will be reported to the PI. Deviations will be documented and reported according to IRB policy. Regulatory documents will be audited by the Baylor Research Institute Department of Research Compliance upon request.

Interventions

None listed

Sponsors

Anteris Technologies Ltd.
CollaboratorINDUSTRY
Baylor Research Institute
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Scheduled for carotid endarterectomy (CEA) with patch arterioplasty * Expected lifespan of over 24 months * Age over 18 years

Exclusion criteria

* Revision of previous CEA arterioplasty * Active infection * Cerebral ischemic event (completed stroke) within 30 days of planned surgery * Pregnant or breastfeeding * Concomitant surgical or endovascular procedure being performed

Design outcomes

Primary

MeasureTime frameDescription
6 Month Duplex US Report to Measure Material QualityUp to 6 months post CEAThe 6 month duplex US report will measure peak velocity and flow through the repaired carotid artery, caliber, and occlusion/lesion status as per normal parameters used in post-CEA scans.

Secondary

MeasureTime frameDescription
OR Data and Surgeon Feedback During the ProcedureprocedureThe OR data from the procedure including blood loss and how long it took to achieve hemostasis in addition to surgeon feedback on bleeding, handling, and suturing of the material will be collected on a source worksheet.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026