Effect of Lens Presentation on the Clinical Oculomotor Assessment at Near

Effect of Lens Presentation on the Clinical Oculomotor Assessment at Near

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02679313
Enrollment
0
Registered
2016-02-10
Start date
2016-02-29
Completion date
2016-09-30
Last updated
2025-05-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Vision Disorders

Brief summary

This study will compare near clinical oculomotor parameters (heterophoria, vergence ranges, AC/A and accommodative findings) measured when lenses and/or prisms are introduced using three different instruments namely: (i) a standard manual phoropter, (ii) an electronic phoropter and (iii) a wearable adaptive refractor (VisionFit).

Detailed description

Previous studies have demonstrated differences in a number of near oculomotor parameters \[e.g., heterophoria, accommodative convergence to accommodation (AC/A) ratio\] when measured in a manual phoropter versus a trial frame. These differences may be due to variations in proximal vergence, differences in head and eye position and restriction of the peripheral visual field. Further, a number of standard clinical oculomotor procedures require the use of Risley rotary prisms. While prism is typically introduced in a smooth, ramp-like fashion with manual phoropters, step changes in prism are created with electronic phoropters. The precise effect of these variations on clinical measurements is unclear. Accordingly, after a routine refractive examination, a standard clinical near assessment (comprising near heterophoria, AC/A ratio, horizontal vergence ranges, amplitude of accommodation and negative and positive relative accommodation) will be carried out on the same individuals through: (i) a standard manual phoropter (American Optical model 11625), (ii) an electronic phoropter (Topcon CV-5000) and (iii) a wearable adaptive refractor (VisionFit). The latter resembles a trial frame mounted on a helmet carrier (similar to a binocular indirect ophthalmoscope headset) but includes adaptive lenses that can be changed electronically.

Interventions

DEVICEPhoropter

Each subject will be tested on 3 separate occasions using either the manual phoropter (American Optical 11625), electronic phoropter (Topcon CV-5000) or the wearable adaptive refractor (VisionFit). Oculomotor measurements, i.e., heterophoria, vergence ranges, AC/A and accommodative findings will be measured at each session using the different devices. Each session will be separated by a minimum of 24 hours and a maximum of 14 days.

Sponsors

State University of New York College of Optometry
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC

Eligibility

Sex/Gender
ALL
Age
18 Years to 30 Years
Healthy volunteers
Yes

Inclusion criteria

* Corrected visual acuity of at least 20/20 (logMAR = 0.0) or better in each eye

Exclusion criteria

* Strabismus, amblyopia, manifest ocular disease.

Design outcomes

Primary

MeasureTime frameDescription
Near horizontal heterophoriaapproximately 15 minutesNear horizontal heterophoria (measured in prism diopters) will be recorded using both the Von Graefe and Modified Thorington techniques using each of the three lens presentation devices. The single set of measurements will be recorded approximately 15 minutes after the start of the trial.
Accommodative convergence to accommodation (AC/A) ratioapproximately 15 minutesThe AC/A ratio will be calculated from measurements of near horizontal heterophoria (quantified in prism diopters) will be recorded using the Modified Thorington technique at 3 different accommodative stimulus levels (1.5D, 2.5D and 3.5D). Measurements will be obtained using each of the three lens presentation devices and calculated in units of prism diopter per diopter accommodation.The single set of measurements will be recorded approximately 15 minutes after the start of the trial.
Horizontal near vergence rangesapproximately 15 minutesNear base-in and base-out vergence ranges will be measured (in prism diopters) while the subject fixates a near target. Measurements will be expressed in terms of the blur point, break point and recovery measurement .The single set of measurements will be recorded approximately 15 minutes after the start of the trial.
Minus lens amplitude of accommodationapproximately 15 minutesMinus lens amplitude of accommodation (measured in diopters) will be recorded using each of the three lens presentation devices.The single set of measurements will be recorded approximately 15 minutes after the start of the trial.

Secondary

MeasureTime frameDescription
Negative and Positive Relative Accommodation (NRA and PRA)approximately 15 minutesNRA and PRA (measured in diopters) will be recorded using each of the three lens presentation devices.The single set of measurements will be recorded approximately 15 minutes after the start of the trial.