Skip to content

The Evaluation of Pre-Post Smoke Evacuation Uses on Surgical Smoke and Bio-Aerosols in Operating Rooms

The Evaluation of Pre-Post Smoke Evacuation Uses on Surgical Smoke and Bio-Aerosols in Operating Rooms at a University Hospital, Thailand

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02672969
Enrollment
128
Registered
2016-02-03
Start date
2015-08-31
Completion date
2016-03-31
Last updated
2016-02-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Smoke

Keywords

smoke evacuation system, surgical smoke

Brief summary

This study aims to evaluate the pre-post smoke evacuation uses on surgical smoke and bio-aerosols particles in operating rooms at a university hospital, Thailand.

Detailed description

Purpose of Project Smoke and bio-aerosols are routinely produced by surgical instruments; eg, lasers, electrosurgical units, radiofrequency devices, ultrasonic devices, power tools. Plume and bio-aerosols contain odor-causing and odorless toxic gases, vapors, dead and live cellular debris (including blood fragments), and viruses. These airborne contaminants can pose respiratory, ocular, dermatological and other health-related risks, including mutagenic and carcinogenic potential, to patients and operating room personnel. The National Institute of Occupational Safety and Health (NIOSH) and the Center for Disease Control (CDC) have also studied electrosurgical smoke at length. Therefore, the equipment of smoke evacuation in OR needs to be used. Therefore, this study aims to evaluate the pre-post smoke evacuation uses on surgical smoke and bio-aerosols particles in operating rooms at a university hospital, Thailand. Methodology Association of periOperative Registered Nurses (AORN) guideline is used as the conceptual framework of this study including evidence based practice for smoke and bio-aerosols evacuation systems. The study design is a quasi-experimental study (manipulation and control only, without randomization) comparing the amount of surgical smoke and bio-aerosols particles pre- post smoke evacuation uses. The samples consist of 64 cases of surgical patients who receive head-neck or breast surgery and 64 cases of surgical patients who receive abdominal laparoscopic surgery. The amount of surgical smoke and bio-aerosols' particles in the surgical field and OR environment are measured by AeroTraxTM Handheld Airborne Particle Counter Model 9306.

Interventions

DEVICERapidVac Smoke Evacuator

The intervention group, using the smoke evacuation (RapidVac Smoke Evacuator) in each OR, the data collection for the amount of surgical smoke and bio-aerosols' particles will be collected during pre-surgery and during surgery (every 30 mins). Before using the smoke evacuation, the amount of surgical smoke and bio-aerosols' particles in the surgical field and OR environment will be measured by AeroTraxTM Handheld Airborne Particle Counter. This record includes the amount and size of smoke and bio-aerosol particles in each area such as anesthetic area (anesthesiologist physicians and nurses area); instrument preparation area (circulating nurses area) and surgical area (surgeons and scrub nurses areas).

Sponsors

Medtronic - MITG
CollaboratorINDUSTRY
Mahidol University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Surgical patients who receive head-neck or breast surgery or surgical patients who receive abdominal laparoscopic surgery

Exclusion criteria

* Emergency cases

Design outcomes

Primary

MeasureTime frameDescription
The amount of surgical smoke and bio-aerosols' particles in the Head, Neck & Breast/ Laparoscopic abdominal surgical field will be measured by AeroTraxTM Handheld Airborne Particle Counter Model 930Operating time, about 1- 3 hoursMeasuring the smoke particles and using data record for the amount of particles (particles/ft3)(millions) in 3 areas; anesthetic area, instrument preparation area, and surgical area for the Head, Neck & Breast surgery/Laparoscopic abdominal surgery

Secondary

MeasureTime frameDescription
The size of surgical smoke and bio-aerosols' particles in the Head, Neck & Breast /Laparoscopic abdominal surgical field will be measured by AeroTraxTM Handheld Airborne Particle Counter Model 930Surgical time 1-3 hoursMeasuring the particle size and using data record for size of particles (μm) (from 0.3 to 10 μm) in 3 areas; anesthetic area, instrument preparation area, and surgical area for the Head, Neck & Breast surgery/Laparoscopic abdominal surgery

Countries

Thailand

Contacts

Primary ContactSunantha Thonklai, MS
sue_thon@hotmail.com+66865274498
Backup ContactUsavadee Asdornwised, PhD
usavadee.asd@mahidol.ac.th+66891285486

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026