Assessing the Comparability of 2D and 4D Ultrasound Measurements

Assessing the Comparability of 2D and 4D Ultrasound Measurements of Human Carpal Tunnel Synovium, Median Nerve and Tendon Displacement

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02666911
Enrollment
0
Registered
2016-01-28
Start date
2018-01-31
Completion date
2019-01-31
Last updated
2017-08-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Carpal Tunnel

Brief summary

Investigators will recruit 20 healthy volunteers between the ages of 18 and 80, who have no history of carpal tunnel syndrome or wrist injury. Images will be captured twice, first with the 2D transducer and then with the 4D transducer and compared to images captured with the new 4D transducer, using the same movement data analysis protocols. Investigators will also assess the inter and intrarater reliability of the 4D transducer images, by using two different sonographers, both trained in the technique, measuring the same blinded images on separate occasions, at least two weeks apart. The overall goal of this project is to assess the reliability, or reproducibility, of measurements in normal subjects using a novel 4D ultrasonographic method to characterize the subsynovial connective tissue (SSCT) and detect motion between SSCT, median nerve and tendon motion for the evaluation and diagnosis of patients with disorders affecting the carpal tunnel, especially carpal tunnel syndrome (CTS).

Detailed description

CTS can be diagnosed in many ways, but there are currently no non-invasive methods to assess the physiology within the carpal tunnel, which may help select treatment and predict treatment outcomes. The investigators have shown in preliminary work that differences in the motion of various structures within the carpal tunnel, including the median nerve, flexor tendons, and SSCT, vary in normal subjects and those with CTS. A clinical trial is already under way to assess conventional ultrasound imaging to predict outcomes of CTS treatments. In this study investigators wish to compare the current ultrasound methods, which involve moving two dimensional images, with a new technology which captures moving images in three dimensions (i.e., four dimensions, or 4D). If successful, a single 4D measurement could replace longitudinal and transverse 2D images, saving time and allowing better understanding of the relationship between displacements in both planes.

Interventions

PROCEDURE4D Ultrasound

Each subject will be imaged lying supine on imaging table with affected arm outstretched on Plexiglass board. An ultrasound scanner equipped with 15L8 linear array transducer will be set to depth of 20-25 mm with a 15MHz image acquisition frequency (for longitudinal and transverse imaging) and the same ultrasound machine equipped with 4D transducer will be used. Ultrasound evaluation will be performed by a sonographer trained in the pertinent image acquisition procedures. The image acquisition frame rate will be maintained at 70Hz, and the image compression will be set to low.

PROCEDURE2D ultrasound

Each subject will be imaged lying supine on imaging table with affected arm outstretched on Plexiglass board. An ultrasound scanner equipped with 15L8 linear array transducer will be set to depth of 20-25 mm with a 15MHz image acquisition frequency (for longitudinal and transverse imaging) and the same ultrasound machine equipped with 4D transducer will be used. Ultrasound evaluation will be performed by a sonographer trained in the pertinent image acquisition procedures. The image acquisition frame rate will be maintained at 70Hz, and the image compression will be set to low.

Sponsors

Mayo Clinic
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

• Healthy Volunteers

Exclusion criteria

* Cervical radiculopathy * Rheumatoid arthritis * Osteoarthritis * Flexor tendinitis * Gout * Hemodialysis * Sarcoidosis * Peripheral nerve disease * Amyloidosis * Traumatic injury - same arm

Design outcomes

Primary

MeasureTime frameDescription
shear index between SSCT and flexor digitorum superficialis 3 tendon (FDS3)1 yearthe relative motion of the SSCT and FDS3 on longitudinal video clips, expressed as a ratio of SSCT/FDS3

Secondary

MeasureTime frameDescription
motion of the median nerve1 yearon cross sectional images, in mm from starting point, while the wrist is flexed
shape of median nerve1 yearon cross sectional images, both cross sectional area in mm squared, and shape in terms of circularity (X axis divided by Y axis)

Outcome results

None listed