Skip to content

CyberHeart's Cardiac Arrhythmia Ablation Treatment: Patients With Refractory Ventricular Tachycardia/Fibrillation

CyberHeart's Cardiac Arrhythmia Ablation Treatment: Patients With Refractory Ventricular Tachycardia

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02661048
Enrollment
5
Registered
2016-01-21
Start date
2015-02-27
Completion date
2023-07-06
Last updated
2023-09-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tachycardia, Ventricular

Brief summary

The objective of this clinical investigation is to evaluate: 1. the safety and efficacy of the CyberHeart System, CardioPlan™ Software and Laptop, in treating patients with refractory ventricular tachycardia (VT) using the CyberKnife® Radiosurgical System. 2. The CyberHeart System performance with respect to the ability to contour myocardial targets that are transferred to the Multi-plan® Treatment Planning Software of the CyberKnife® system for the production and delivery of a safe radiosurgical treatment plan. Cardiac radiosurgery is a minimally-non invasive, painless, procedure. Tissue ablation can be accomplished precisely.

Detailed description

This study is a prospective, multi-center (2), single arm, open label US-based feasibility study. The clinical hypothesis for the study is that the CyberHeart treatment approach will be safe and with further study will not be shown to be inferior to current treatment options, may lead to a survival benefit and improved quality of life. The ablation to be performed with the CyberHeart System will be targeting the anatomical site of the clinically presenting VT. The application site will be determined by morphological criteria on the 12 lead ECG along with anatomical data from MRI or CT scan imaging. Ablation will be performed at the designated location with the intention to produce substrate modification. The Study will enroll a maximum of 10 patients.

Interventions

DEVICECyberHeart System

The CyberHeart system uses proprietary software to assist the cardiologist to contour ablation targets. Standard radiosurgical techniques are then used to accomplish ablation

Sponsors

Varian, a Siemens Healthineers Company
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
60 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Presence of an implantable cardioverter-defibrillator (ICD) * Patients with ischemic or non-ischemic cardiomyopathy who have had recurrent symptomatic VT that induced ICD shock(s) following catheter ablation and/or antiarrhythmic drug (AAD) therapy. * 60 years of age or greater. * Left ventricular ejection fraction ≥ 20%. * Failure of or ineligible for catheter ablation.

Exclusion criteria

* Unable or unwilling to provide informed consent * Patients with idiopathic VT * Women who are pregnant * Prior radiation therapy to the thorax * Active ischemia or other reversible causes of VT * Active non-cardiovascular illness or systemic infection * Presence of thrombus in the right atrium or right ventricle on pre-procedure echocardiogram * Cardiogenic shock * NYHA (New York Heart Association) Class IV Heart Failure. * Presence of incessant VT that is hemodynamically unstable. * Acute heart failure exacerbation. * Revascularization in the past 90 days. * Other disease process that is likely to limit survival to less than 12 months

Design outcomes

Primary

MeasureTime frameDescription
Outcome 1 is the Number of participants with Treatment related Serious Adverse Events as assessed by CTCAE v. 4.012 months (360 days) with Outcome assesment in first 30 days adn in days 31 to 1 year post treatment.Outcome 1 is measured by The number of Participants, and the percentage of participants with : \- Serious Adverse Events; (1) in the first 30 days, (2) in days 31 to 1 year post treatment, both treatment related, and non-treatment related, separately tabulated.

Secondary

MeasureTime frameDescription
Number of participants with a change in SF-36 Medical Outcomes Health Survey, as compared to pre-treatment questionaire responses12 monthsParticipants will complete a SF-36 (Short Form-36) Medical Outcomes Survey before treatment and at each post treatment follow-up check. Absolute numeric numbers will be tabulated and percentage change will be calculated
Number of defibrillation shocks as compared to pretreatment occurrence12 monthsDefibrillation shocks will be recorded pre-treatment and post treatment at each follow-up visit.
Ventricular arrhythmia episodes, as compared to pretreatment occurrence12 monthsThe number of ventricular tachycardia episodes that required either anti-tachycardia pacing, or that self-terminated, will be recorded pre- and post treatment.
Left ventricular function post treatment12 monthsLeft ventricular systolic and diastolic function will be assessed by echocardiography pre- and post treatment

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 27, 2026