Skip to content

pRotective vEntilation With Veno-venouS Lung assisT in Respiratory Failure

pRotective vEntilation With Veno-venouS Lung assisT in Respiratory Failure

Status
UNKNOWN
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02654327
Acronym
REST
Enrollment
1120
Registered
2016-01-13
Start date
2016-05-12
Completion date
2022-04-30
Last updated
2022-03-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Respiratory Failure With Hypoxia

Keywords

Extracorporeal, Acute Respiratory Distress Syndrome, Protective Lung Ventilation, Ventilator Induced Lung Injury, Carbon Dioxide Removal, Lung, Lung Injury

Brief summary

This is a trial of a new way of treating patients with respiratory failure. The investigators propose to deliver a multi-centre clinical trial to determine whether veno-venous extracorporeal carbon dioxide removal (VV-ECCO2R) and lower tidal volume mechanical ventilation improves outcomes and is cost-effective, in comparison with standard care in patients who are mechanically ventilated for acute hypoxaemic respiratory failure

Detailed description

Acute hypoxaemic respiratory failure requiring mechanical ventilation is a major cause of morbidity and mortality. A significant proportion of affected patients will have the Acute Respiratory Distress Syndrome (ARDS). Mechanical ventilation is often required to provide adequate gas exchange and although it is life-saving in this setting, it is also now known to contribute to the morbidity and mortality in the condition. Ventilators delivering high pressures and volumes cause regional over distension in the injured lung resulting in further inflammation and non-cardiogenic pulmonary oedema. The release of inflammatory mediators from the damaged lung causes systemic inflammation leading to multi-organ failure and death. The few interventions that have been shown to reduce the high mortality in these patients have targeted ventilator-induced lung injury (VILI). A landmark trial by the ARDSNet trials group found that ventilating patients with acute hypoxaemic respiratory failure secondary to ARDS with a lung protective strategy aiming for a reduced tidal volume of 6ml/kg predicted body weight (PBW) and a maximum end-inspiratory plateau pressure (Pplat) ≤ 30cmH2O decreased mortality from 40% (in the conventional arm treated with tidal volume less than 12ml/kg PBW) to 31%. Extracorporeal carbon dioxide removal (ECCO2R) in association with mechanical ventilation offers a potentially attractive solution to permit tidal volume reduction to less than 6ml/kg PBW and to achieve low plateau pressures (\< 25cmH2O). Using these extracorporeal circuits, carbon dioxide can be 'dialysed' out of the blood while the lungs are ventilated in a more protective manner. In recent years, more efficient veno-venous devices have become available. These have replaced arterio-venous devices and have the advantage of not requiring arterial puncture. These can achieve carbon dioxide removal with relatively low extracorporeal blood flows (0.4-1 l/min) requiring only a smaller dual lumen venous catheter. In addition these ECCO2R devices use more biocompatible materials making the device more resistant to clot formation and cause less platelet and clotting factor consumption. Therefore only minimal systemic anticoagulation is required which reduces the likelihood of bleeding complications. These devices are now comparable to renal dialysis equipment, which is routinely used safely as standard care in ICUs in the United Kingdom. Together this highlights the need for a large randomised controlled trial to establish whether VV-ECCO2R in acute hypoxaemic respiratory failure can allow the use of a more protective ventilatory strategy and is associated with improved patient outcomes. Importantly, if there was no benefit, the trial would provide evidence to stop the widespread adoption of an expensive and ineffective or potentially harmful treatment in this setting.

Interventions

DEVICEVV-ECCO2R to enable lower tidal volume mechanical ventilation

In the intervention arm a dual lumen catheter will be inserted into a central vein. VV-ECCO2R is commenced and managed as per study manual. Tidal volumes are then reduced on mechanical ventilation to enable lower tidal volume ventilation. Lower tidal volume facilitated by VV-ECCO2R will continue for a least 2 days up to a maximum of 7 days

Sponsors

Queen's University, Belfast
CollaboratorOTHER
Northern Ireland Clinical Trials Unit
CollaboratorOTHER
Belfast Health and Social Care Trust
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
16 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Invasive mechanical ventilation using positive end expiratory pressure (PEEP) ≥ 5cmH2O * Acute and potentially reversible cause of acute respiratory failure as determined by the treating physician * Within 48 hours of the onset of hypoxemia as defined by Pa02/Fi02 less than or equal to 20kPA

Exclusion criteria

* Age \< 16 years old * Intubated and mechanically ventilated via an endotracheal or tracheostomy tube ≥ 7 days (168 hours) up to the time of randomisation * Ability to maintain Vt to ≤ 3ml/kg PBW while maintaining pH ≥ 7.2 as determined by the treating physician * Receiving, or decision to commence, ECMO in the next 24 hours * Mechanical ventilation using high frequency oscillation ventilation or airway pressure release ventilation * Untreated pulmonary embolism, pleural effusion or pneumothorax as the primary cause of acute respiratory failure * Acute respiratory failure fully explained by left ventricular failure or fluid overload (May be determined by clinical assessment or echocardiography/cardiac output monitoring) * Left ventricular failure requiring mechanical support * Contra-indication to limited systemic anticoagulation with heparin * Unable to obtain vascular access to a central vein (internal jugular or femoral vein) * Consent declined * Treatment withdrawal imminent within 24 hours * Patients not expected to survive 90 days on basis of premorbid health status * DNAR (Do Not Attempt Resuscitation) order (excluding advance directives) in place * Severe chronic respiratory disease requiring domiciliary ventilation (except for sleep disordered breathing) * Severe chronic liver disease (Child Pugh \>11) * Platelet count \< 40,000 mm3 (Prior to catheter insertion) * Previously enrolled in the REST trial * Prisoners

Design outcomes

Primary

MeasureTime frame
All cause mortality90 days after randomisation

Secondary

MeasureTime frame
Tidal volume (ml/kg Predicted Body Weight)day 2 and day 3 after randomisation
Ventilator free days28 days after randomisation
Duration of ventilation in survivors28 days after randomisation
Need for Extracorporeal Membrane Oxygenation (ECMO)7 days after randomisation
Mortality rate28 days, 6 months and 1 year after randomisation
Health Related Quality of Life6 months and 1 year after randomisation
Health & Social Care Service costs6 months and 1 year after randomisation
St George Respiratory Questionnaire1 year after randomisation
Need for home oxygen6 months and 1 year after randomisation
Post Traumatic Stress Syndrome Questionnaire (PTSS-14)1 year after randomisation
Montreal Cognitive Assessment (MoCA-BLIND) or AD8 Dementia Screening Interview (AD8)1 year after randomisation
Adverse Event Rate28 days

Other

MeasureTime frameDescription
Right Ventricular functionBaseline & Day 2/Day 3Change in tricuspid annular plane systolic excursion (TAPSE) in cm at day 2 or 3 from randomisation measured with echocardiography

Countries

United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 6, 2026