Skip to content

Neural Compensation, Visual Function and Visual Quality After Monofocal or Multifocal Intraocular Lens Implantation

Neural Compensation, Visual Function and Visual Quality in Senile Cataract Patients After Monofocal or Multifocal Intraocular Lens Implantation

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02644720
Enrollment
50
Registered
2016-01-01
Start date
2014-01-31
Completion date
2019-01-31
Last updated
2016-01-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Brief summary

Multifocal intraocular lenses (MIOLs) provide enhanced far and near visual acuity, but they can bring about halos and glare, which are caused by design deficiencies of the IOLs. Compared to monofocal intraocular lens, pseudo accommodation in nonphysiological state may increase the difficulty of neural compensation reconstruction in patients with multifocal intraocular lens implantation. Patients enrolled into the study will be followed for 1 year and will have study visits preoperatively, at 1 week, 3 months, 6 months, 12 months postoperatively.In this trial, we aimed to specify the time of neural compensation reconstruction in patients and to explore the changes of visual function in senile patients with monofocal or multifocal intraocular lens implantation.

Detailed description

Cataract extraction and intraocular lens (IOL) implantation are the current standard treatments for age-related cataract (ARC). Cataract surgery increases visual acuity but may lead to complaints after surgery. Multifocal intraocular lenses (MIOLs) provide enhanced far and near visual acuity, but they can bring about halos and glare, which are caused by design deficiencies of the IOLs. Fortunately, most of the halos and glare diminish with time. Niels et al noted that neural adaptation (NA) may explain the lower incidence of glare and halos in their study. Compared to monofocal intraocular lens, pseudo accommodation in nonphysiological state may increase the difficulty of neural compensation reconstruction in patients with multifocal intraocular lens implantation. In the present study, the investigators evaluated the activity of neurons in the visual cortex using fMRI both preoperatively and postoperatively. In addition, the investigators evaluated postoperative changes in VF, including visual acuity (VA), contrast sensitivity (CS), straylight values (SVs), and pattern visual evoked potential (PVEP), stereoscopic vision, wavefront aberrations at 1 week, 3 months, 6 months, 12 months postoperatively.In this trial, the investigators aimed to specify the time of neural compensation reconstruction in patients and to explore the changes of visual function in senile patients with monofocal or multifocal intraocular lens implantation.

Interventions

PROCEDUREmultifocal intraocular lens implantation

In this group, the surgery was performed with cataract extraction and multifocal intraocular lens (IOL) (Tecnis ZMB00). The standard technique in all patients consisted of sutureless phacomulsifacation using the Legacy 2000 Series and Infinity phacoemulsification machine (Alcon Laboratories Inc., Fort Worth, Texas, USA), with clear corneal incisions up to 3.2 mm and 5.0 to 5.5 mm capsulorhexis. Surgery in the fellow eye was performed 1 month later in each patient.

In the group, the surgery was performed with cataract extraction and monofocal intraocular lens (IOL) (Tecnis ZCB). The surgery technique was same as the multifocal intraocular lens group

DRUGDexamethasone

All patients received subconjunctival dexamethasone (2 mg) during surgery

DEVICEmultifocal intraocular lens (IOL) (Tecnis ZMB00)
DEVICEmonofocal intraocular lens (IOL) (Tecnis ZCB)

Sponsors

First Affiliated Hospital, Sun Yat-Sen University
CollaboratorOTHER
Sun Yat-sen University
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
45 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* visual acuity less than 0.3 * Cataracts in both eyes classified by the Lens Opacity Classification System III * Corneal astigmatism less than 1.5 diopters (D) * Capability of understanding and signing the informed consent

Exclusion criteria

* Corneal astigmatism ≥ 1.5D. * History of neurological or psychiatric disorders; systemic disease such as severe hypertension or diabetes mellitus that might interfere with the visual outcomes. * Associated ocular disease that could interfere with final results * Previous anterior and posterior segment surgery and intraoperative or postoperative complications * Driving at night frequently; excessive expectations for visual outcomes

Design outcomes

Primary

MeasureTime frameDescription
Change from contrast sensitivity1 week, 1 month, 3 month, 6 month,1 year after surgeryContrast sensitivity (CS) was tested with a Contrast Glare Tester 1000
Change from functional magnetic resonance imaging1 week, 1 month, 3 month, 6 month,1 year after surgery

Secondary

MeasureTime frame
Change from best corrected visual acuity1 week, 1 month, 3 month, 6 month,1 year after surgery

Countries

China

Contacts

Primary ContactHaotian Lin, M.D.;Ph.D.
haot.lin@hotmail.com+8613802793086

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 7, 2026