Safety and Efficacy of Using SightSaver Visual Evoked Potential (VEP) for VEP Monitoring in Prone Spine Surgery

A Pilot Study to Determine the Efficacy and Safety of Detecting Subtle Visual Changes During Visual Evoked Potential (VEP) Monitoring Using SightSaver ™ Flash Visual Evoked Potential Stimulator in Spine Prone Surgery

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02643615
Acronym
SightSaver
Enrollment
20
Registered
2015-12-31
Start date
2014-09-30
Completion date
2016-03-31
Last updated
2017-08-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ischemic Optic Neuropathy

Keywords

Visual Evoked Potentials

Brief summary

Post-operative visual loss (POVL) following non-ocular surgical procedures is an infrequent but severe complication. Little is understood about this complication, but most cases seem to result from loss of blood flow to the optic nerve. This is a pilot, single center, prospective, randomized, two-arm study involving 20 subjects at The Ohio State University Wexner Medical Center who are scheduled to undergo spine surgery that requires prone position and at least two hours of general anesthesia or total intravenous anesthesia (TIVA) and intraoperative neurophysiological monitoring. Patients will be randomized to either general anesthesia or TIVA, and wear the SightSaver device to monitor visual evoked potentials (VEPs) during surgery in order to detect possible changes in optic nerve function that may lead to POVL. We hypothesize that this new, flexible, disposable device will yield better results and more patient satisfaction than devices currently used for visual monitoring during prone spine surgeries.

Detailed description

The exact mechanism underlying POVL is poorly understood, but nearly all cases seem to involve ischemic optic neuropathy (ION). Posterior ION is more commonly the result of spinal procedures. The spine surgery associated risk factors include: prone position, Trendelenburg positioning, blood loss, prolonged procedure, use of vasoconstriction agents to correct blood pressure, direct ocular compression, and hypotension \[1,2\]. Given the fact that the suspected mechanism is a gradual infarction of the optic nerve, POVL could theoretically be prevented based on early detection of reversible optic nerve dysfunction. Visual evoked potentials (VEP) are a highly sensitive method for detecting optic nerve dysfunction, including ischemia. During intraoperative neurophysiological monitoring (IONM), an emitted light passes through the lens, reaching the retina and causing hyperpolarization. The signal generated by the retina in response to a flash of light is known as the electroretinogram (ERG). This response may be recorded using conventional neurophysiological equipment and reflects overall retinal function. The VEP peaks are generated during the passage of electrical signal from the retina via the optic pathways to the primary visual cortex, and can also be registered during IONM. Measurements of VEP peaks under anesthesia can vary depending on type of anesthetic regimen, some producing more interference with the electrical impulses than others. The problems encountered during VEP monitoring are numerous: a reusable device must be cleaned in between patients, tightly fitting goggles pose a risk of damaging the eyes, goggles may fall off or move intraoperatively and be difficult to reposition once the procedure is underway. Also, the light emitting diodes tend to be too weak to produce an adequate stimulus. This pilot study presents a new different approach from current methods. The SightSaverTM visual stimulator design consists of the following key advantages over the current technologies: hygienically superior to re-usable goggles, provides physical protection to the ocular region, use of higher intensity diodes and adhesive foam padding shaped to contours of periocular region. This pilot, single center, prospective, randomized, two-arm study will involve 20 subjects at The Ohio State University Wexner Medical Center who are scheduled to undergo spine surgery that requires prone position and at least two hours of general anesthesia or TIVA and intraoperative neurophysiological monitoring. Eligible subjects that provide voluntary and written informed consent will be included in the study with a 1:1 randomization ratio of two arms, n=10 patients per each of two anesthesia regimen groups: general anesthesia and TIVA. All patients will wear the SightSaverTM visual stimulator. IONM of VEP with include insertion of half-inch needle electrodes placed just under the skin on either side of the eye, at the top of the forehead and three along the back of the head. Flashes of light, delivered at continuous intervals, will be emitted from diodes mounted in the SightSaverTM visual stimulator. After the baseline VEP is established for the patient, monitoring of VEP will occur at every 30 minutes during surgery. If during the monitoring process, a significant VEP waveform change has occurred, an alert will trigger the surgical staff to check four different parameters: technical issues with goggles, anesthetic changes, significant blood loss or a blood pressure change. Analysis of data collected will be used to evaluate the efficacy of SightSaverTM visual stimulator for intraoperative VEP-based detection of significant visual changes during prone spine surgeries.

Interventions

DEVICEVEP under TIVA

Propofol will be administered for anesthesia maintenance in patients randomized to the TIVA arm of the study. In order to record the VEPs, standard half-inch sub-dermal needle electrodes will be inserted subcutaneously around the visual area and the SightSaverTM visual stimulator will be placed to monitor VEP during surgery.

DEVICEVEP under balanced anesth.

Balanced general anesthesia with desflurane will be administered for anesthesia maintenance in patients randomized to the balanced general anesthesia arm of the study, In order to record the VEPs, standard half-inch sub-dermal needle electrodes will be inserted subcutaneously around the visual area and the SightSaverTM visual stimulator will be placed to monitor VEP during surgery.

DRUGPropofol

Propofol will be administered for anesthesia maintenance in patients randomized to the TIVA arm of the study. In order to record the VEPs, standard half-inch sub-dermal needle electrodes will be inserted subcutaneously around the visual area and the SightSaverTM visual stimulator will be placed to monitor VEP during surgery.

DRUGDesflurane

Balanced general anesthesia with desflurane will be administered for anesthesia maintenance in patients randomized to the balanced general anesthesia arm of the study, In order to record the VEPs, standard half-inch sub-dermal needle electrodes will be inserted subcutaneously around the visual area and the SightSaverTM visual stimulator will be placed to monitor VEP during surgery.

Sponsors

Ohio State University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Male or Female older than 18 years of age * American Society of Anesthesiologists (ASA) status of I to IV and scheduled to undergo elective spinal prone position procedures under general anesthesia or TIVA only with intraoperative neurophysiological monitoring with an expected duration of surgery to be at least 2 hours * If female, have been surgically sterilized or are postmenopausal; if of child-bearing potential, must have a negative serum pregnancy test the day of surgery * Ability and willingness to sign informed consent * Literate in the English language

Exclusion criteria

* Prisoner status * Women who are pregnant or lactating/breast feeding * Patients with a history of contact allergies to foam and/or plastic devices * Any condition, which, in the opinion of the investigator, would make the subject ineligible for participation in the study, such as a history of unstable cardiovascular, pulmonary, renal, hepatic, neurologic (seizures), hematologic or endocrine abnormality (hyperthyroidism, unstable Diabetes type I/II)

Design outcomes

Primary

MeasureTime frameDescription
Efficacy in Detecting Subtle Intraoperative VEP Changes Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVA.VEP waveforms recorded every 30 minutes during the entire procedure for up to 6 hours.Number of Participants with Subtle Intraoperative VEP Changes Observed Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVA

Secondary

MeasureTime frameDescription
The Difference in VEP Changes in Amplitude Among Both GroupsEvery 30 minutes during surgery for up to 6 hoursVEP waveforms were evaluated using either present baseline - reproducible positive-negative-positive complex of substantial amplitude (≥2 µV) that appeared 100-200 ms after pulse stimulus onset; marginal Baseline - low amplitude (\<2 µV) reproducible P100 waveform; or absent baseline - no repeatable response present. Any activity of \<0.5 µV was not considered a response. Best derivation for each particular patient was used for monitoring electroretinogram (ERG) recording and confirming the stimulation.
Safety of Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVAFrom start of surgery up to 24 hours after surgeryNumber of participants experiencing adverse events related to the study procedures during prone surgery and 24 hours after surgery under balanced general anesthesia versus TIVA

Countries

United States

Participant flow

Participants by arm

ArmCount
VEP Under TIVA
Patients undergoing prone spine surgery will receive an anesthesia regimen using propofol (TIVA) for maintenance VEP under TIVA: Propofol will be administered for anesthesia maintenance in patients randomized to the TIVA arm of the study. In order to record the VEPs, standard half-inch sub-dermal needle electrodes will be inserted subcutaneously around the visual area and the SightSaverTM visual stimulator will be placed to monitor VEP during surgery. Propofol: Propofol will be administered for anesthesia maintenance in patients randomized to the TIVA arm of the study. In order to record the VEPs, standard half-inch sub-dermal needle electrodes will be inserted subcutaneously around the visual area and the SightSaverTM visual stimulator will be placed to monitor VEP during surgery.
9
VEP Under Balanced Anesthesia
Patients undergoing prone spine surgery will receive an anesthesia regimen using Desflurane as part of balanced general anesthesia VEP under balanced anesth.: Balanced general anesthesia with desflurane will be administered for anesthesia maintenance in patients randomized to the balanced general anesthesia arm of the study, In order to record the VEPs, standard half-inch sub-dermal needle electrodes will be inserted subcutaneously around the visual area and the SightSaverTM visual stimulator will be placed to monitor VEP during surgery. Desflurane: Balanced general anesthesia with desflurane will be administered for anesthesia maintenance in patients randomized to the balanced general anesthesia arm of the study, In order to record the VEPs, standard half-inch sub-dermal needle electrodes will be ins
11
Total20

Baseline characteristics

CharacteristicVEP Under Balanced AnesthesiaVEP Under TIVATotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
0 Participants0 Participants0 Participants
Age, Categorical
Between 18 and 65 years
11 Participants9 Participants20 Participants
Age, Continuous56.2 years
STANDARD_DEVIATION 16.1
52.3 years
STANDARD_DEVIATION 14.8
54.5 years
STANDARD_DEVIATION 15.3
Region of Enrollment
United States
11 participants9 participants20 participants
Sex: Female, Male
Female
4 Participants6 Participants10 Participants
Sex: Female, Male
Male
7 Participants3 Participants10 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 90 / 11
other
Total, other adverse events
0 / 90 / 11
serious
Total, serious adverse events
0 / 90 / 11

Outcome results

Primary

Efficacy in Detecting Subtle Intraoperative VEP Changes Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVA.

Number of Participants with Subtle Intraoperative VEP Changes Observed Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVA

Time frame: VEP waveforms recorded every 30 minutes during the entire procedure for up to 6 hours.

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
VEP Under TIVAEfficacy in Detecting Subtle Intraoperative VEP Changes Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVA.1 Participants
VEP Under Balanced AnesthesiaEfficacy in Detecting Subtle Intraoperative VEP Changes Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVA.1 Participants
Secondary

Safety of Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVA

Number of participants experiencing adverse events related to the study procedures during prone surgery and 24 hours after surgery under balanced general anesthesia versus TIVA

Time frame: From start of surgery up to 24 hours after surgery

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
VEP Under TIVASafety of Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVA0 Participants
VEP Under Balanced AnesthesiaSafety of Using SightSaver Visual Stimulator During Spine Prone Surgeries Under Balanced General Anesthesia Versus TIVA1 Participants
Secondary

The Difference in VEP Changes in Amplitude Among Both Groups

VEP waveforms were evaluated using either present baseline - reproducible positive-negative-positive complex of substantial amplitude (≥2 µV) that appeared 100-200 ms after pulse stimulus onset; marginal Baseline - low amplitude (\<2 µV) reproducible P100 waveform; or absent baseline - no repeatable response present. Any activity of \<0.5 µV was not considered a response. Best derivation for each particular patient was used for monitoring electroretinogram (ERG) recording and confirming the stimulation.

Time frame: Every 30 minutes during surgery for up to 6 hours

ArmMeasureValue (MEDIAN)
VEP Under TIVAThe Difference in VEP Changes in Amplitude Among Both Groups0.66 micorvolts (µV)
VEP Under Balanced AnesthesiaThe Difference in VEP Changes in Amplitude Among Both Groups0.48 micorvolts (µV)
Secondary

The Difference in VEP Changes in Amplitude Among Both Groups

The difference in VEP changes in amplitude with a single and double stimuli using the SightSaver visual stimulator under balanced general anesthesia versus TIVA.

Time frame: every 30 minutes during the entire procedure for up to 6 hours

ArmMeasureValue (MEAN)
VEP Under TIVAThe Difference in VEP Changes in Amplitude Among Both Groups14.21 milliseconds (ms)
VEP Under Balanced AnesthesiaThe Difference in VEP Changes in Amplitude Among Both Groups17.94 milliseconds (ms)

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026