Critical Illness
Conditions
Keywords
ultrasonography, catheterization, central line, mechanical ventilation, intensive care, axillary vein, jugular vein, randomization
Brief summary
The main intention of this study is to compare two ultrasound-guided central venous catheterization procedures namely: real-time, ultrasound-guided, in plane axillary vein catheterization and real-time, ultrasound-guided, out of plane jugular vein catheterization in terms of venipuncture, catheterization success, early mechanical complication and catheter-related infection rate in mechanically ventilated patients admitted to the intensive care unit.
Interventions
Sponsors
Study design
Eligibility
Inclusion criteria
* mechanically ventilated intensive care patients with clinical indications for central venous line placement
Exclusion criteria
* trauma and hematoma at the catheterization site * major blood coagulation disorders coincided with active bleeding * anatomical abnormalities at the catheterization site * infection at the catheterization site * age less than 18 years * lack of patients or closest relatives consent
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Procedure success rate | 24 hours | to define catheterization success rate |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Incidence of Catheter colonization | 1 month | to assess the incidence of catheter colonization after removal |
| Incidence of catheter-related bloodstream infection | 1 month | to assess the incidence of catheter-related bloodstream infection |
| Procedure complication rate | 24 hours | to assess the early mechanical complication rate |
Countries
Poland